§ 54-32 — Amendments and additions
Code of the City of Springfield, Missouri (Supp. No. 23, Update 2: codified through G.O. No. 6973, enacted January 12, 2026) · Springfield, Mo., City Code § 54-32
Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/40188866-0ae2-4816-816b-5a6b7c182fcd
Sec. 54-32. - Amendments and additions.
The following sections and subsections of the International Fire Code, 2024 Edition, as adopted by this article, are amended and changed, or enacted as additions thereto to be placed within the sequential numbering system of the International Fire Code, 2024 Edition, with such amended and new sections and subsections, to read as follows: Chapter 1 - Administration SECTION 101 SCOPE AND GENERAL REQUIREMENTS [A] 101.1 Title. The provisions of Chapter 54 of the Springfield City Code shall be known as the Fire Code of the City of Springfield, Missouri, and may be referred to herein as "this code". SECTION 102 APPLICABILITY [A] 102.5 Application of residential code. Where structures are designed and constructed in accordance with the International Residential Code, the provisions of this code shall apply as follows: 1. Construction and design provisions of this code pertaining to the exterior of the structure shall apply including, but not limited to, premises identification, fire apparatus access and water supplies. Where interior or exterior systems or devices are installed, construction permits required by Section 105.6 shall apply. In addition, Section 907.2.11.2.1 of this code shall apply. 2. Administrative, operational and maintenance provisions of this code shall apply. SECTION 104 GENERAL AUTHORITY AND RESPONSIBILITIES [A] 104.4 Right of Entry. Whenever necessary for the purpose of enforcing the provisions of this code, or whenever the fire official has reasonable cause to believe that there exists in any structure or upon any premises any condition which makes such structure or premises in violation of this code, the fire official may enter such structure or premises at all reasonable times to inspect such structure or premises or to perform any duty imposed upon the fire official by this code; provided that if such structure of premises be occupied, posted for "no trespassing," or locked or otherwise secured, the fire official shall first present proper credentials and request entry, except for emergencies to save lives or property. Notwithstanding such provisions, entry may be had by the fire official in all public or commercial places or structures and those spaces or areas that are open and accessible to the public. If an inspection is required under this code as a condition for the issuance or the renewal of a permit or license, then refusal to provide access for such inspection shall constitute cause to issue a stop work order or revoke or refuse to issue the permit or license under the Springfield City Code. If such entry is refused, the fire official shall have recourse to every remedy provided by law to secure entry. If an official who has a duty to perform under this code has been refused access to a structure or property or any part thereof, and if such official has probable cause to believe that there may be a violation of this code or that there is a need to inspect as part of a routine inspection program of the City designed to protect the overall public health, safety and welfare of the community, then upon an application by the City Attorney to the Municipal Court Judge and a showing of the above, the Municipal Court Judge of the City of Springfield shall issue a search and seizure warrant describing therein the specific location subject to the warrant. The warrant shall specify what may be searched and/or seized on the property described. Such warrant shall be served at reasonable hours and only by an official of the department in the company of a uniformed police officer of the City of Springfield. 104.10 Fire investigations. The code official shall investigate, or cause to be investigated, every fire or explosion occurring within the jurisdiction that is of a suspicious nature or which involves the loss of life or serious injury or causes destruction or damage to property. Such investigation shall be initiated immediately upon the occurrence of such fire or explosion; and if it appears that such an occurrence is of a suspicious nature, the code official shall immediately take charge of the physical evidence; and, in order to preserve any physical evidence relating to the cause or origin of such fire or explosion, the code official shall take means to prevent access by any person to the structure or premises until such evidence has been properly processed. The code official shall notify those persons designated by law to pursue investigation into such matters and shall further cooperate with the authorities in the collection of evidence and prosecution of the case and shall pursue the investigation to its conclusion. SECTION 105 PERMITS [A] 105.4.1 Revocation of permits and utilities. Whenever the code official has ordered a person to correct a violation and when such violation has not been corrected within the time specified by such order, thereafter the code official may institute an administrative action to revoke any and all permits issued by the city under which the activity is being conducted, including business licenses, occupancy permits, rental property registration, and the right to receive utilities for the activity or building or structure where the activity is conducted, by filing a notice of institution of contested case before an administrative hearing officer in accordance with Article X of the Land Development Code. 105.5.34 Mobile food preparation vehicles. A permit is required for mobile food preparation vehicles equipped with appliances that produce smoke or grease-laden vapors. All permitting and inspections associated with mobile food preparation vehicles will be issued/completed through Health, Environmental Services or Building Development Services Departments. Violations of the Fire Code noted by those Departments during inspection activities are to be addressed by Fire Department personnel as requested. 105.5.40 Outdoor Assembly Event. All outdoor assembly event permitting is handled by Special Event Permitting through the City Manager's Office. [A] 105.5.51 Temporary membrane structures and tents. Any person or company erecting a tent or membrane structure shall ensure the operator of the tent or membrane structure has obtained the required operational permit for tents or membrane structures prior to erecting the tent or membrane structure. This applies to tents and membrane structures having an area in excess of 400 square feet or multiple tents erected within 12 feet of each other totaling 700 square feet. Tents shall be erected in accordance with SFD Appendix T. SECTION 110 MAINTENANCE 110.3.1 Inspection, testing and maintenance recordkeeping. When required inspection, testing or maintenance occurs on any existing fire protection systems, applicable documentation shall be submitted to the fire code official through an approved third-party inspection reporting system. Reporting parties shall pay any fees associated with that service to the City's third-party provider. SECTION 112 BOARD OF APPEALS [A] 112.1 Means of Appeals-Review of a decision. Any party aggrieved by a decision of the fire code official may seek review of said decision in a court of law pursuant to Chapter 536, RSMo., and Rules of the Missouri Supreme Court adopted thereto. [A] 112.2 Limitations on Authority. An application for appeal shall be based on a claim that the intent of this code or the rules legally adopted hereunder have been incorrectly interpreted, the provisions of this code do not fully apply, or an equivalent method of protection or safety is proposed. SECTION 113 VIOLATIONS [A] 113.3 Prosecution of violations. If a person violates the Fire Code, or if a notice of violation is not complied with within the time specified by the fire official, the fire official may cause a municipal court summons to be issued and the City Attorney may, at the fire official's request, institute a court proceeding to obtain an injunction to restrain, correct or abate such violation, or to require removal or termination of the provisions of this code or of any order or direction made pursuant thereto. [A] 113.4 Violation penalties. Any person, as defined in Section 1-2 of the Springfield City Code, violating any provisions of the Fire Code, this ordinance, or failing to comply with any order issued pursuant to any section thereof, shall be guilty of a violation of a municipal ordinance and upon conviction thereof shall punished as provided in Section 1-7 of the Springfield City Code. Each day that a violation continues shall be deemed a separate offense, except that service of a notice, as required by subsection 110.3.2 shall be required to prosecute for failure to comply with an order. SECTION 114 STOP WORK ORDER [A] 114.4 Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be liable to a fine of not less than One Hundred dollars ($100) or more than Five Hundred dollars ($500). Each day of violation shall constitute a separate offense. Chapter 2 - Definitions SECTION 202 GENERAL DEFINITIONS [A] Owner. Any person, agent, firm or corporation having a legal or equitable interest in the property. Recyclable. Any clean, source-separated flammable or combustible material that is used to manufacture or re-manufacture an end product that has market value or replaces a natural resource. Waste, Combustible. Magazines, books, trimmings from lawns, trees or flower gardens, leaves, pasteboard boxes, rags, paper, straw, sawdust, packing materials, shavings, roofing materials, waste oil, cooking oils, storage of all materials, boxes and all rubbish and refuse that will ignite through contact with flames at ordinary temperatures. Chapter 3 - General Requirements SECTION 304 COMBUSTIBLE WASTE MATERIAL 304.2.1 Waste Material. The equipment, processes, and operations of vehicle wrecking yards, junkyards and waste material handling plants, and the storage of combustible or flammable waste, rubbish and other materials shall comply with this chapter. In addition to the specific operations listed, these requirements also apply to landfills, scrap yards, salvage yards, trash dumps, tree and stump dumps, tire dumps, recycling facilities, solid waste incinerators and waste reduction plants. Any facility which handles, stores or processes used, discarded or damaged materials, other than those classified as hazardous materials or hazardous waste, are governed by these provisions. SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES 307.1 General. A person shall not cause or allow any open burning unless approved in accordance with this code and Chapter 6 of the Springfield City Code (air pollution control standards). 307.1.1.1 Illegal Burning of Waste Materials. Unauthorized and unpermitted burning of waste materials as defined in Chapter 2 of the Fire Code to include the burning of insulation from wiring containing metals such as copper and aluminum, whether obtained legally or illegally, shall be considered a violation of this code. 307.1.2 Time of open burning. In no event shall open burning take place between the hours of 4:00 p.m. and 6:00 a.m., except that the fire code official may authorize open burning different from the above standards when he/she finds the public health and safety will not be endangered. 307.1.3 Wind speed. In no event shall open burning take place during sustained wind speeds of fifteen (15) miles per hour or higher. 307.4.1 Bonfires. A bonfire shall not be conducted within 50 feet (15 240 mm) of a structure or combustible material. Conditions which could cause a bonfire to spread within 50 feet (15 240 mm) of a structure shall be eliminated prior to ignition. 307.4.1.1 Bonfire materials, size, and duration of burning. A bonfire shall not be more than 5 feet by 5 feet by 5 feet. Fuel for a bonfire shall consist only of seasoned dry firewood and shall be ignited with a small quantity of paper. Bonfires shall not burn longer than 4 hours and must be extinguished by midnight of the day of the permit. Bonfires shall meet all other requirements set forth in this code for outside fires, to include a means of extinguishment, appropriate distances from structures, wind speed less than 15 miles per hour, and a responsible adult supervising the entire duration of the burn. SECTION 308 OPEN FLAMES 308.1.7 Sky Lanterns. Sky Lanterns which utilize an open flame are specifically prohibited for use within the city limits. A sky lantern, also known as Kongming lantern, Chinese lantern, sky candle, or fire balloon, is a small hot air balloon made of paper, plastic, Mylar, or other lightweight material, with an opening at the bottom where a small fire is suspended. 308.4.1 Group R-2 occupancies. Candles, incense and similar open-flame-producing items shall not be allowed in Group R-2 occupancies. Exception: In apartment buildings, this provision shall apply to only the common areas. SECTION 311 VACANT PREMISES 311.1.1 Abandoned premises. Buildings, structures and premises for which an owner cannot be identified or located by dispatch of a certificate of mailing to the last known or registered address, which persistently or repeatedly become unprotected or unsecured, which have been occupied by unauthorized persons or for illegal purposes, or which present a danger of structural collapse or fire spread to adjacent properties shall be considered abandoned, declared unsafe and abated by demolition or rehabilitation in accordance with the International Property Maintenance Code and the International Building Code and/or other local ordinances. SECTION 323 LANDSCAPING MATERIALS 323.1 General. Structures utilizing landscaping materials applied adjacent to the exterior of the building shall comply with the requirements of this section. Existing structures undergoing expansion or remodel are only required to bring new sections of the building into compliance with this section. Exceptions: 1. One- and two-family dwellings, 2. Residential occupancies with 6 or less dwelling units 323.2 Definitions. Combustible landscaping material/mulch: describes any of the following materials, regardless of individual chip size. Materials include, but are not limited to, the following organic materials: mulch and wood chips, pine needles, leaves, and cut grass clippings or any other combustible material. Shredded rubber, although in-organic, is included as combustible landscaping material for the purposes of this section. Noncombustible landscaping materials include but are not limited to: rock or pea stone and brick chips. Alternative noncombustible landscaping materials shall be approved by the fire code official prior to use. 323.3 Grass. Use of viable and living grass/sod is allowed at any proximity. 323.4 Clearances. Where landscaping material is used around a building, the following clearances shall be maintained. 1. Combustible landscaping material/mulch shall not be placed within 18 inches (457 mm) of any commercial structure. Non-combustible landscaping material is allowed at any proximity. 2. Combustible landscaping materials/mulch shall be maintained so there is not less than 18 inches (457 mm) radius of horizontal clearance around gas meters. Non-combustible landscaping material is allowed at any proximity. 323.5 Receptacles for Discarded Smoking Materials. Where combustible landscaping material/mulch is utilized, receptacles for discarded smoking materials shall meet the following: 1. Receptacles shall be placed not closer than 18" (457 mm) from combustible landscape material/mulch plots. 2. Receptacles for the disposal of smoking materials shall be regularly emptied. Chapter 4 - Emergency Planning SECTION 403 EMERGENCY PREPAREDNESS REQUIREMENTS 403.9.2.1 College and university buildings. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for Group R-2 college, university, fraternity and sorority buildings. Group R-2 college, university, fraternity and sorority buildings shall comply with Sections 403.9.2.1.1 and 403.9.2.1.2. SECTION 405 EMERGENCY EVACUATION DRILLS 405.3.1 Frequency variance. Fire drill frequency for Group E occupancies may be modified when an approved evacuation plan and training program is approved by the fire code official. Chapter 5 - Fire Service Features SECTION 503 FIRE APPARATUS ACCESS ROADS 503.2.4 Turning Radius. The required minimum inside turning radius of a fire apparatus access road shall be 28 feet. 503.3.1 When required. The requirements of Section 503.3 shall apply to all new construction, change of occupancy classification, and when required by the code official. 503.3.2 Methods. The following methods shall be used and shall include the words NO PARKING—FIRE LANE and shall be provided for fire apparatus access roads to identify such roads or prohibit obstruction thereof. 503.3.2.1. A 4 inch red stripe shall be applied on each side of the fire apparatus access road and shall be applied along the entire length of the fire apparatus access road. If one or both sides of the access road are enclosed by a curb then the curb shall be marked in red. Additionally, the words "NO PARKING—FIRE LANE" shall be stenciled in letters no less than 12 inches high with a width of 2 inches inside of the fire apparatus access road every 50 feet along the entire length of the fire apparatus access road. The means by which fire lanes are designated shall be maintained in a clean and legible condition at all times and be replaced or repaired when necessary to provide adequate visibility. Alternative markings and/or marking methods may be approved by the fire code official. 503.3.2.2. If a Fire Lane extends more than 400 feet from a structure, that portion of the fire lane may be marked with "No Parking - Fire Lane" at 100 foot intervals. The portion(s) of the fire lane in proximity to the structure must be marked at 50 foot intervals. 503.3.2.3. Low hazard industrial sites with limited or no public access may be allowed to extend the "No Parking - Fire Lane" stencil to 100 foot intervals around all or a portion of the entire site. 503.3.2.4. "No Parking - Fire Lane" will be required to be marked within 25 feet of an access point to a public/private street. 503.3.2.5 Alternative Fire Lane Marking. Upon review and approval by the fire code official, in specific instances, such as an apartment complex with internal access lanes, signs may be posted in lieu of the currently required red stripes and stenciling. Signs must be posted at each entrance, readily visible and unobstructed. Signs shall state "All Drive Aisles are Considered Fire Lanes - No Parking". Signage must meet minimum requirements as detailed in Section D103.6, sign type D, with the incorporation of the additional wording. SECTION 505 PREMISES IDENTIFICATION 505.1 Address identification. New and existing buildings shall have approved address identification numbers. The assigned address number shall be clearly posted on the site immediately after the date of issuance of the permit and shall remain in conformance with Chapter 26, Section 26-3, Numbering of business and dwelling units, of the Springfield City Code. The same requirements for business address identification for the front of the business building shall apply to the rear of the business building. Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall not be less than 4 inches (102mm) high with a minimum stroke width of ½ inch (12.7mm). The fire code official may require larger numbers and letters depending upon building size and distance from the roadway. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification numbers shall be maintained. SECTION 506 KEY BOXES 506.1 Where required. Key boxes are required in new and existing buildings where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the fire code official is authorized to require a key box to be installed in an approved location. The key box shall be the KNOX BOX brand and shall contain master keys, fobs, access cards, door codes, or any other means to gain necessary access as required by the fire code official. Any security doors and/or security gates installed with a key pad entry or a magnetic card swipe reader shall have a KNOX BOX brand key operated switch installed for emergency entry where required by the fire code official. 506.1.1 Locks. A KNOX BOX brand lock shall be installed on gates or similar barriers where required by the fire code official. 506.1.2 Boxes. For multi-occupancy structures that are less than 400 feet in length, one Knox brand key box shall be installed near the most central occupancy and mounted 5 feet above the finished grade. Boxes shall contain master keys, fobs, access cards, door codes, or any other means of gaining the necessary access for each occupancy in the building. For multi-occupancy structures that are greater than 400 feet in length, one Knox brand key box shall be placed every 200 feet of frontage and mounted 5 feet above the finished grade. Boxes shall contain master keys, fobs, access cards, door codes, or any other means of gaining the necessary access for each occupancy in the building. SECTION 507 FIRE PROTECTION WATER SUPPLIES 507.2.1.1 Private fire service mains. Private fire service mains and appurtenances shall be installed in accordance with NFPA 24. Directional boring shall not be utilized for the installation of private fire service mains. 507.2.1.2 Private fire service fire hydrant colors. Private fire service hydrants shall be red in color. The bonnet and caps shall be painted in accordance with NFPA 291 and shall apply to new and existing hydrants. 507.5.1 Where required. Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 400 feet (122 m) from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official. Exceptions: 1. For Group R-3 and Group U occupancies, the distance requirement shall be 600 feet (183m). 2. For buildings equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the distance requirement shall be 600 feet (183m). 3. As an alternative method, the nearest hydrant must be within 400 feet of the furthest point of approved fire apparatus access provided the fire apparatus access point meets 503.1.1. The distance may be extended to up to 600 feet if the occupancy meets the requirements of 507.5.1 Exception 2. SECTION 509 FIRE SERVICE IDENTIFICATION 509.1 Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves, or other fire detection, suppression or control elements shall be identified for the use of the fire department. Approved signs required to identify fire protection equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. When in an enclosed space or room, the door closest to the fire pump, fire riser and fire alarm control panel shall be labed [labeled] as "Fire Pump", "Fire Sprinkler Riser" and/or "Fire Alarm Panel" in letters a minimum of 2" in height with a brush stroke of ¼" on a contrasting background or as approved by the fire code official. 509.1.2 Exterior Fire Protection. All portions of fire protection systems exterior to a building shall be painted in gloss safety red. Chapter 9 - Fire Protection Systems SECTION 901 GENERAL 901.4.3 Alterations in buildings and structures. For any alteration within a building or structure, the fire protection and life safety systems may be extended, altered or augmented in order to maintain and continue protection within the building. Persons shall not remove or modify any fire protection or life safety system installed or maintained under the provisions of this code or the International Building Code without approval granted throughout the plans review process, or express consent by the fire code official. 901.6 Inspection, testing and maintenance. Fire detection and alarm systems, emergency alarm systems, gas detection systems, fire-extinguishing systems, mechanical smoke exhaust systems, smoke and heat vents, and fire protection and life safety systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. The property owner and any lessees, sublessees, or other persons in charge or control of premises required to have smoke alarms installed and operational, shall be jointly and individually responsible for the proper operation and maintenance of such alarms. 901.6.1.1 Certifications. Persons performing required fire protection system(s), water supply, commercial kitchen hoods, and clean agent systems testing and maintenance as the lead inspector shall possess a valid certification from The National Institute for Certification in Engineering Technologies as the industry standard. NICET Level II certification is required for the lead inspector for each type of fire protection system inspected, tested, or maintained by the vendor. The lead inspector is responsible for supervision and approval of the testing process and its documentation. NICET Level I certification is preferred for individuals working under the lead inspector. Sprinkler systems Standpipe systems Fire pump(s) Fire alarm systems Private fire hydrant(s) 901.6.3.2 Inspection, testing and maintenance records. Records of all system inspections, testing and maintenance required by the referenced standards shall be maintained on the premises for a minimum of 3 years and shall be copied to the Springfield Fire Department via the designated third-party records management company as stipulated by the Springfield Fire Department, see section 108.3.1. Records shall include the name of the certified maintenance/testing individual, type of testing or maintenance completed and results of the maintenance or testing. A GREEN, YELLOW, RED tag system will be utilized for all fire protection system(s). All tags utilized in the City of Springfield will be provided by the Springfield Fire Department. 901.6.3.2.1 Green and yellow tag required. Upon completion of the inspection, if the system is found to be fully functional and meets the requirements of the standard(s) in effect at the time of installation, the inspector shall affix a GREEN tag to the system which includes the inspector and inspection company's name and the date of the inspection. If the system is found to be deficient by the standard(s) in effect at the time of installation, or the system needs repair, but the system is still functional then the inspector shall affix a YELLOW tag to the system which includes the inspector and the inspection company's name and a list of the needed repairs. Tags shall be placed in a conspicuous location on the system. 901.6.3.2.2 Notifications. If upon completion of the inspection, a fire protection system is found to be deficient and in need of repairs by the standard(s) in effect at the time of installation but is still functional, the inspector shall indicate all needed repairs or deficiencies to the system on the report sent to the Springfield Fire Department via the designated third-party records management company as stipulated by the Springfield Fire Department, see section 108.3.1. The report shall be submitted within 7 days of completion of the inspection. 901.6.3.2.3 Red tag required. A RED tag shall be used to indicate a system, or portion thereof, has been removed from service, and/or is not functionable and/or does not meet the necessary requirements to validate a functionable system. The RED tag shall be placed on a conspicuous place on the system and the Springfield Fire Department shall be notified IMMEDIATELY by phone at 874-2300 during business hours and 911 after business hours. The RED tag notification will also be reported via the designated third-party records management company during the standard report submission. SECTION 903 AUTOMATIC SPRINKLER SYSTEMS 903.4.1 Monitoring. Alarm, supervisory and trouble signals shall be distinctly different and shall be automatically transmitted to an approved supervising station or, where approved by the fire code official, shall sound an audible signal at a constantly attended location. Any sprinkler system failing to monitor the valves, other than the below listed exceptions, will not be allowed to be "green tagged". Those systems shall be "yellow tagged" by the inspection company. The issue shall be remedied within twelve months or by the next inspection of the sprinkler system. Failure to complete the remedy within the time allowed shall demand the sprinkler system to be "red tagged". Occupancies undergoing permitted work to renovate or substantially modify the fire sprinkler system, or a change of use of occupancy, shall also comply with the monitoring requirements of this section. Exceptions: 1. Any existing and accepted system whose valves are chained and locked in the open position will be deemed compliant. 2. Underground key or hub valves in roadway boxes provided by the municipality or public utility are not required to be monitored. 3. Underground key or hub valves in roadway boxes for the purpose of use as a segment control or isolation valve when use of a post indicator value is not practical, and upon the approval of the fire code official. 4. Backflow prevention device control valves located in limited area sprinkler system supply piping shall be locked in the open position. In occupancies required to be equipped with a fire alarm system, backflow preventer valves located internal to the structure shall be electrically supervised by a tamper switch installed in accordance with the NFPA 72 and separately annunciated. 5. Backflow prevention device control valves located external to the structure, or located within a vault, must be secured control valve to control valve by a chain of one-quarter of one-inch thickness and secured by a padlock. A padlock key shall stay with the property manager, and a padlock key shall be placed in a key box in compliance with Section 506 of this Code. 903.4.3 Alarms. Springfield Fire Department requires a weatherproof horn-strobe notification device, installed on the exterior of the building, directly above the fire department connection at approximately 8'-10' above final grade with approved signage directly below. SECTION 906 PORTABLE FIRE EXTINGUISHERS 906.2.1 Certification of service personnel for portable fire extinguishers. Service personnel providing or conducting maintenance on portable fire extinguishers shall possess a valid certificate from a nationally recognized industry standard certifying agency for the type of work performed. SECTION 907 FIRE ALARM AND DETECTION SYSTEMS 907.2.9.4 All one- and two-family rental properties within the jurisdiction are required to adhere to the IRC 2018 as adopted by the City of Springfield, section R314.3 regarding smoke alarm installation locations. It shall be the property owners' responsibility to provide and maintain these smoke alarms according to the individual manufacturers guidelines. SECTION 912 FIRE DEPARTMENT CONNECTIONS 912.1.1 Fire Department connection size. In no circumstances shall any fire department connection be a device other than 2½ inch Siamese using NST threads, including systems that are otherwise required to comply with NFPA 13R and NFPA 13D. 912.4.1 Locking fire department connection caps. KNOX BOX brand locking fire department connection caps are required on all fire department connections for water-based fire protection systems. 912.4.1.1 Locking fire connection caps on existing buildings. Existing buildings with non-locking fire department connection caps will not be required to install locking fire department connection caps unless it is determined by the fire code official the fire department connection is no longer adequately protected from obstructions because of missing non-locking caps. 912.7 Inspection, testing and maintenance. Fire department connections shall be periodically inspected, tested and maintained in accordance with NFPA 25. If the inspector finds the fire department connection unprotected and missing a non-locking cap(s), the cap(s) shall be replaced with the approved KNOX BOX brand locking fire department connection cap(s). Records of inspection, testing and maintenance shall be maintained. Chapter 10 - Means of Egress SECTION 1004 OCCUPANT LOAD 1004.9.1 Assembly Occupancies. Assembly occupancies are provided Certificates of Occupancy from the City which have their authorized occupant loads posted on them. These Certificates of Occupancy must be displayed in a clearly visible area near the main entrance of the Assembly Occupancy. SECTION 1008 MEANS OF EGRESS ILLUMINATION 1008.3.4 Testing and maintenance. Where the means of egress is required to be illuminated as stated in section 1008.2, periodic testing and maintenance of the egress lights shall be performed. Testing shall be conducted on monthly and annual intervals. Monthly testing shall include visual verification that the egress light operates upon actuation of the test button, if provided, to momentarily disconnect the egress light from the primary power source. Annual testing shall include disconnecting the egress lights from the primary power source to ensure egress illumination for a duration of not less than 90 minutes. All deficiencies shall be repaired. Records shall be kept of the testing and maintenance performed including dates and names of personnel performing the tests. Records shall be made available for review upon request of the fire code official. Exception: If the egress light illumination emergency power source is supplied by a generator or other such means, monthly and annual testing may be completed by visual verification of illumination under normal conditions. SECTION 1010 DOORS, GATES AND TURNSTILES 1010.1.8 Security Bars. Security bars, commonly referred to as burglar bars, are locking devices designed to prevent the operation of a door typically by means of a bar installed across the doorframe and held by cradles attached to the door(s). Security bar locking devices may be allowed on certain exit doors upon approval by the fire code official. Approval may be granted where all the following conditions are met: 1. The exit is not the primary means of egress for the general public. 2. The exit is limited to an area typically occupied only by staff/employees familiar with the building and locking arrangement (store room, stock room, office, etc.). 3. There may be no locking device on the security bar. 4. The security bar shall be removeable without the use of a key or special knowledge or effort. 5. The security bar must be removed during any period of occupancy by the general public (if the exit serves the public area). 6. A readily visible durable sign is posted on the egress side on, or adjacent to, the door stating: "Security bar must be removed when the building is occupied" (if the exit serves the public area). 7. Not more than one-half of the required exits shall be equipped with a security bar. 8. The use of a security bar shall not be allowed if, in the opinion of the fire code official, it compromises the safety of the public. 9. The use of a security bar is revocable by the fire code official for due cause. SECTION 1013 EXIT SIGNS 1013.6.4 Testing and maintenance. Where exit signs are required to be illuminated as stated in section 1013.3, periodic testing and maintenance shall be performed. Testing shall be conducted on monthly and annual intervals. Monthly testing shall include visual verification that the exit sign is illuminated under normal operation and with actuation of the test button, if provided, to momentarily disconnect the exit sign from the primary power source. Annual testing shall include disconnecting the exit signs from the primary power source to ensure exit sign illumination for a duration of not less than 90 minutes. All deficiencies shall be repaired. Records shall be kept of the testing and maintenance performed including dates and names of personnel performing the tests. Records shall be made available for review upon request of the fire code official. Exception: If the exit sign illumination emergency power source is supplied by a generator or other such means, monthly and annual testing may be completed by visual verification of illumination under normal conditions. SECTION 1032 MAINTENANCE OF THE MEANS OF EGRESS 1032.1.1 Grill or other cooking device storage. For other than one- and two-family dwellings, no grill, hibachi or other similar devices used for cooking shall be stored under a combustible stairway that is part of a means of egress. Chapter 11 - Existing Buildings SECTION 1103 EXISTING BUILDINGS Chapter 12 - Energy Systems SECTION 1203 EMERGENCY AND STANDBY POWER SYSTEMS 1203.5 Operational inspection and testing. Emergency power systems, including all appurtenant components, shall be inspected and tested under load in accordance with NFPA 110 and NFPA 111. Emergency generators required by the building code shall be tested at least annually in accordance with the manufacturer's specifications under anticipated conditions. Chapter 31 - Tents SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES 3103.2.1 Permitting. For permit requirements within the City of Springfield for tents and other temporary or membrane structures, refer to Appendix T, Section T102. 3103.8.3 Tents and membrane structures greater than 7,500 square feet. Tents and membrane structures greater than 7,500 square feet (697 M2) shall be designed and constructed to comply with Sections 1606 through 1609 of the International Building Code. Exception: Tents and membrane structures greater than 7,500 square feet which are erected, anchored and braced as required by Appendix T of this code may be permitted, subject to approval of the fire code official, where all of the following conditions are met: 1. The tent or membrane structure is erected, anchored and braced to withstand 45 mph sustained winds at a minimum; and 2. The tent or membrane structure shall be evacuated when 30 mph sustained winds are reached; and 3. The tent or membrane structure shall not be occupied during periods when ice and/or snow accumulation is predicted or exists; and 4. The installer shall inspect the tent at least once per 7-day period erected and/or after rains, high winds, snow/ice or severe weather conditions have occurred at the tent's location and take corrective actions as needed; and 5. The enhanced requirements must be relayed to the event manager/end user during the consumer safety awareness consultation. The consultation document shall be posted within the tent. 6. The permit may be revoked by the fire code official with cause. 3103.8.4 Tents and membrane structures with an occupant load greater than 1,000. Tents and membrane structures with an occupant load greater than 1,000 persons shall be designed and constructed to comply with Sections 1606 through 1609 of the International Building Code. Exception: Tents and membrane structures with an occupant load of greater than 1,000 persons which are erected, anchored and braced as required by Appendix T of this code may be permitted, subject to approval of the fire code official, where all of the following conditions are met: 1. The tent or membrane structure is erected, anchored and braced to withstand 45 mph sustained winds at a minimum; and 2. The tent or membrane structure shall be evacuated when 30 mph sustained winds are reached; and 3. The tent or membrane structure shall not be occupied during periods when ice and/or snow accumulation is predicted or exists; and 4. The installer shall inspect the tent at least once per 7-day period erected and/or after rains, high winds, snow/ice or severe weather conditions have occurred at the tent's location and take corrective actions as needed; and 5. The enhanced requirements must be relayed to the event manager/end user during the consumer safety awareness consultation. The consultation document shall be posted within the tent. 6. The permit may be revoked by the fire code official with cause. 3103.8.5. Tent installation. For specifics associated with tent installation in the City of Springfield, refer to Appendix T, Sections T105—T114. 3103.11.6.1 Exit Sign Illumination. Exceptions: i. Exit signs are not required on tents that have limited sides or sidewalls installed. Sides that are attached, but in the stowed or rolled-up position, are considered the same as if the sidewalls are down. To qualify as limited sidewalls, a tent may have no more than the length of the longest side of the tent with sides or sidewalls; and ii. The tent or membrane structure does not exceed 7,500 square feet (697 square meters); and iii. The tent or membrane structure is only occupied by members of the public during daylight hours. SECTION 3107 OUTDOOR ASSEMBLY EVENTS 3107.2.1. Approval required. Outdoor assembly events may be approved by the fire code official. 3107.3.1 Occupant load. The fire code official may establish an occupant load for the event site. SECTION 3108 OPERATIONAL REQUIREMENTS 3108.4 Open or exposed flame. Open flame or other devices emitting flame, fire or heat or any flammable or combustible liquids, gas, charcoal or other cooking device or any other unapproved devices shall not be permitted inside or located within 20 feet (6096mm) of the tent or membrane structures while open to the public. 3108.4.1 Exceptions: 1. The fire code official may approve cooking inside a tent or membrane structure under the following criteria: i. Only persons engaged in food preparation may be inside the tent or membrane structure; and ii. No seating is provided inside the tent or membrane structure for other than those persons engaged in food preparation; and iii. The sides of the tent or membrane structure are metal or nylon mesh, of a screen-type and not a solid fabric; and iv. Containers for the collection of trash are provided inside the tent or membrane structure, and such containers are not within 20 feet to any cooking device or open flame; and v. Only cooking devices approved by the fire code official shall be used and these devices must be properly vented, if powered by LPG no larger than a five (5) gallon bottle is used, and any open flame of a cooking device must be fully enclosed and protected from contact with the fabric of the tent or membrane structure, or other flammable material within said structure; and vi. Any cooking device or trash collection container shall be located so as not to block any means of egress or exit from the tent or membrane structure; and vii. A portable fire extinguisher must be provided inside the tent or membrane structure with a minimum rating of 40:BC; and viii. Any cooking device shall be attended at all times by a competent adult; and ix. The tent or membrane structure meets all other requirements in this Chapter or other City Codes related to tents and membrane structures. 3108.14.1. Exception. Unless determined otherwise by the fire code official, the disconnection of batteries and fuel limitation in displayed vehicles is not required when a tent is erected with only the roof membrane attached and no side walls. SECTION 3405 OUTDOOR STORAGE 3405.4.1 Storage in trailers and containers. Storage of tires in an enclosed trailer or storage container, secured and locked except during business hours, shall be located at least 25 feet from lot lines and buildings in accordance with other City Codes relating to storage trailer and containers. Chapter 41 - Temporary Heating and Cooking Operations SECTION 4101 GENERAL 4101.4.3 Fire extinguishers. Not fewer than one portable fire extinguisher complying with Section 906 with a minimum 2-A: 10-B:C rating or other approved on-site fire-extinguishing equipment shall be available for immediate utilization. 4101.8 Refueling of flammable and combustible liquid-fueled equipment. Refueling operations for liquid-fueled equipment or devices shall be conducted in accordance with Section 575 and all of the following: 1. Refueling operations for liquid-fueling equipment or devices shall be conducted by trained personnel in accordance with the manufacturer's instructions and this code. 2. The equipment oe [or] device shall be turned off and allowed to cool prior to refueling. 3. Refueling operations shall be conducted in a well-ventilated area at a minimum of 20 feet (6096 mm) from any building or structure. 4101.9 Cooking operations. Portable cooking equipment using combustible oils or solids shall comply with all of the following: 1. A noncombustible lid shall be immediately available. The lid shall be sufficient size to cover the cooking well completely. 2. Eqipment [Equipment] shall be placed on a noncombustible surface. 3. A portable fire extinguisher for protection appropriate to the cooking media shall be provided at a location approved by the fire code official. 4. Appropriate clearance from combustible and ignition sources shall be at a minimum of 20 feet (6096 mm). SECTION 4103 PORTABLE FUEL-FIRED HEATING APPLIANCES 4103.1.2.1.3 Clearance to combustible materials. Portable outdoor gas-fired heating appliances shall not be located beneath, or closer than 10 feet (3048 mm) to combustible decorations and combustible overhangs, awnings, sunshades or similar combustible attachments to buildings. SECTION 4104 PORTABLE FUEL-FIRED COOKING APPLIANCES 4104.2 Open flame cooking devices. Charcoal burners and other open-flame cooking devices shall not be operated on combustible balconies or within 10 feet (3048 mm) of combustible construction. Exceptions: 1. One- and two-family dwellings. 4104.4 Cooking operations. Cooking that produces sparks or grease-laden vapors shall not be performed within 20 feet (6096 mm) of a tent or membrane structure except where the following conditions are met: 1. Cooking devices shall be isolated from the public. 2. Cooking devices shall be maintained and used according to the manufacturer's instructions. 3. A "Class K" portable fire extinguisher is readily available. 4. 3-foot clearance is maintained from cooking operations and combustibles. Exception: Designated cooking tents with an automatic sprinkler system installed in accordance with Section 903.3.1.1. 4104.5 Separation of cooking tents. Tents with sidewalls or drops where cooking is performed shall be separated from other non-cooking tents or membrane structures by not less than 20 feet (6096 mm). Exception: Small tents limited to 100 square feet (9.3 m 2 ) that are accessory to the cooking operations of the cooking tent and are not occupied by the public. SECTION 4106 MOBILE FOOD PREPARATION VEHICLES 4106.4.2 Fire protection systems and devices. Fire protection systems and devices shall be maintained in accordance with 901.6 and Section 906. 4106.4.3.1 LP-gas systems. LP-gas containers installed on the vehicle and fuel gas piping systems shall be inspected annually by an approved inspection agency, person or special expert who is qualified to ensure that system components are free from damage, suitable for the intended service and not subject to leaking. Mobile food vendors who have a working combustible gas detector and alarm installed inside the food preparation area will not be required to provide evidence of a current passing fuel gas system inspection and test. 4106.6 Solid fuel appliances. Solid fuel cooking appliances shall not be installed or used inside the mobile food preparation kitchen unless the vehicle and the appliance are purpose-built for this purpose. Solid fuel appliances may be installed on an open porch or similar feature, separate from the food preparation kitchen, provided the appliance is vented to open air outside the trailer and does not block egress from the kitchen. 4106.7 Solid fuel. The use of wood burning ovens, smokers, or bbq grills within the mobile food preparation vehicle will require the installation of a carbon monoxide alarm per the manufacturer's recommendations. 4106.7.1 Solid fuel waste. Mobile food preparation vehicles are responsible for the storage and disposal of all solid fuel waste. 4106.8 Ovens. Ovens shall have direct venting in accordance with the manufacturer's recommendations. Chapter 50 - Hazardous Materials SECTION 5006 COST RECOVERY FOR HAZARDOUS SUBSTANCES RELEASES 5006.1 Authority to seek reimbursement. The Fire Department, through the Fire Chief, or his designee, is authorized on behalf of the City, to assess and seek reimbursement for all costs incurred by the Fire Department and the City in response to a hazardous substance release for which it provides services, within the scope of Section 260.546 RSMo. The City Manager is also authorized, in his discretion, to apply for reimbursement for such costs incurred from the hazardous waste fund created in Section 260.391, RSMo, as described in Section 260.546.4, RSMo. The Fire Chief or City Manager are also authorized to seek reimbursement to cover personnel and equipment costs from responsible parties and/or political subdivisions for responses to hazardous substance releases either within or outside of the Springfield city limits. The schedule for such costs shall be set out in the schedule of costs referenced in Subsection 5006.3 below. 5006.2 Process for seeking reimbursement. The Fire Chief, or his designee, shall follow the process set out in Section 260.546, RSMo, in seeking such reimbursement, and shall provide the statement of costs and other documentation as required by the said statute. The City Attorney shall assist and represent the City and the Fire Chief, or his designee, in all proceedings in connection with seeking such reimbursement. 5006.3 Establishing reimbursement rates. The Fire Chief shall also establish a schedule of costs and hourly rates for its responses to such hazardous substance releases, based on actual costs and compensation rates of the personnel involved, which shall be kept on file with the City Clerk and the Fire Department. This schedule may be updated periodically, but not more frequently than once every 12 months, with each revised schedule to be kept on file with the City Clerk and Fire Department. 5006.4 Legal Remedies. This section shall not be deemed to limit in any way the potential legal options, recourses and remedies available to the City to seek recover of its costs and damages from any persons or entities who may be legally responsible for such costs or damages, or who may have a duty to insure or indemnify any such responsible persons or entities. SECTION 5601 SCOPE 5601.1 Scope. Exception: 9. Items preempted by federal regulations and state statutes. 5601.1.3 Fireworks. Exceptions: 1. The use of fireworks displays as allowed in Section 5608. SECTION 5609 TEMPORARY STORAGE OF CONSUMER FIREWORKS SECTION 5707 ON DEMAND MOBILE FUELING OPERATIONS Chapter 61 - Liquefied Petroleum Gases SECTION 6107 SAFETY PRECAUTIONS AND DEVICES Appendix D FIRE ACCESS ROADS SECTION D101 GENERAL D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface cable of supporting the imposed load of fire apparatus weighing up to 85,000 pounds (38,555kg). SECTION D102 REQUIRED ACCESS D102.1.1 Grass Pavers. The use of a grass paver system for a required fire apparatus access road shall be approved by the fire code official. Grass paver systems must be substantially capable of supporting imposed loads of fire apparatus. Plastic style grass pavers will not be permitted. Concrete, or other such substantial style systems, may be approved upon review. Grass paved fire apparatus access roads must comply with marking requirements as set forth in section D103.6.3. SECTION D103 MINIMUM SPECIFICATIONS D103.5 Gate Access. Where required by the fire code official, all automatic fire apparatus gates shall use the Knox brand gate key switch. D103.6 Signs. Where required by the fire code official, fire apparatus access roads shall be marked with permanent NO PARKING—FIRE LANE signage as required in Section 503.3. If signs are required as per section D103.6.3, the signs shall comply with figure D103.6. Signs shall have a minimum dimension of 12 inches (305mm) wide by 18 inches (457mm) high and have red letters on a white reflective background. Signs shall be posted on one or both sides of the fire apparatus road as required by Section D103.6.1 or D103.6.2. Alternative Fire Lane Marking (503.3.3.2.5) signs shall read "All Drive Aisles are Considered FIRE LANE - NO PARKING". Example below. [image omitted; see the official code] D103.6.1 Roads 20 to 26 feet in width. Fire apparatus access roads 20 feet to 26 feet wide (6096 to 7925mm) shall be marked as a Fire Lane as specified in Section 503.3. D103.6.2 Roads more than 26 feet in width. Fire apparatus access roads more than 26 feet wide (7925mm) shall be marked as a Fire lane as specified in Section 503.3. D103.6.3 Roads utilizing grass pavers. This section shall apply to all new and existing fire apparatus roads utilizing grass pavers. Fire apparatus access roads that utilize grass pavers shall be marked with signs as specified in section D103.6 and approved by the fire code official, signs shall be posted on both sides of the fire lane where it exits impervious pavement and shall be marked in an approved manner along the length of the grass fire lane until it enters back onto impervious pavement. Marking along the grass fire lane shall be a design approved by the fire code official. APPENDIX R ALLOWANCES FOR NEIGHBORHOOD DEVELOPMENTS PROVIDING RESIDENTIAL SPRINKLERS User Note: About this appendix: There is precedence within the fire code of making extra allowances for buildings and other occupancies equipped with automatic fire suppression systems. The intent of this appendix is to extend similar allowances to developers of subdivisions and neighborhoods who install residential sprinkler systems in homes and require, through codified covenant agreements, that these systems be properly maintained. Certain requirements of the fire code relating to hydrant spacing and fire department access can be amended. Appendix R lists the requirements a developer must meet for the amended code requirements to apply, as well as the sections of the code that are to be amended and the specific amendments allowed to each section. SECTION R101 GENERAL R101.1 Scope. In new developments where each criteria are met, sections of the fire code relating to hydrant spacing and fire department access may be amended. R101.2 Intent. Certain requirements of the fire code relating to hydrant spacing and fire department access can be amended for neighbor and subdivisions that require residential sprinkler systems in their homes. R101.3 Requirements. The fire code official shall review any plans where amendments to the fire code are attempted under the requirements of this appendix. The fire code official may grant amendments to the code in appendix R103, but meeting the requirements of section 102 does not require that such amendments be granted. The fire code official may determine that new developments must adhere to the original, more stringent requirements of the fire code if other outside circumstances make it prudent to do so. SECTION R102 DEVELOPMENT REQUIREMENTS R102.1 The following requirements must be met by the development for the amendments in appendix R to apply: 1. The use of sprinklers is not required under any section of the adopted fire code. Rather than being required, the sprinkler system is being added in addition to the provisions required by the code. 2. The requirement to install and maintain a residential sprinkler system is codified in the restrictive covenants on the real property deed for all lots in the subdivision. 3. Every building within the developed neighborhood/subdivision must have an automatic sprinkler system installed. This includes each home, as well as buildings such as community rooms, gymnasiums, buildings next to swimming pools, meeting halls, etc. to which members of the covenant have access to and are included as part of the development. 4. The sprinkler requirements codified (see criteria #2) are permanent and cannot be removed. 5. The sprinklers in each residence are installed and maintained according to all applicable codes and the most current NFPA standards governing their installation, testing, and maintenance. SECTION R103 ALLOWABLE AMENDMENTS R103.1 In such instances where all the criteria of Section R102 are met, the fire code may be amended in the following sections: R103.1.1 Hydrant Spacing. Section 507.5.1 exception 2 shall apply. For buildings equipped throughout with an approved automatic sprinkler system installed in accordance with section 903.3.1.1 or 903.3.1.2 the distance requirement shall be 600 feet (183m). R103.1.2 Fire Apparatus Access Roads. Section 503.1.1 The distance requirement shall be within 250 feet (76 200 mm). Section 503.2.1 Dimensions. The distance requirement shall be 18 feet (5 486 mm). Section 503.2.5 Dead Ends. The distance requirement shall be 450 feet (137 160 mm). Section D105.2 Width. The distance requirement shall be 24 feet (7 315 mm). APPENDIX T TENTS AND OTHER MEMBRANE STRUCTURES User Note: About this appendix: Appendix T provides details for the proper and approved method of installing commercially rented tents. The requirement in Chapter 31 requiring tents to be "adequately roped, braced and anchored to withstand the elements of weather" proved too vague for objective review of submitted plans and site inspection approval. This appendix clarifies the specific requirements for the installer and the installation. It includes amendments/addendums adopted in 2015 Council Bill 2015-294 on November 23, 2015. SECTION T101 GENERAL T101.1 Scope. This appendix sets forth the requirements for the installation of commercial tents within the City of Springfield, Missouri. SECTION T102 PERMITS T102.1 Permits. Permits shall be required as set forth in Sections 105.6 and 105.7 and will be obtained from the Fire Department by the owner of the tent or his designee, except where two or more tents will be used as part of an event with a valid City of Springfield Special Event Permit, then the event organizer may apply for the permit. T102.2 Permit application must have a site plan noting the location of the tent and an approved staking/ballasting plan. T102.2.1 The tent user will be required to submit a layout plan for the setup within the tent. This must be provided to the Fire Code Official no later than at the time of the inspection. The permit holder is required to notify the tent user of this requirement. SECTION T103 VENDOR REQUIREMENTS T103.1 Tent Vendor License. T103.1.1 All vendors renting commercial tents for use in the City of Springfield must obtain a one-time no-cost tent vendor license through the Fire Department. T103.1.2 To obtain the license, the owner or his designated employee must: 1. Successfully pass a no-cost training course provided by the Fire Department, which will cover the relevant sections of the City's Fire Codes well as the permitting and installation requirements; and 2. Hold a valid business license for the City of Springfield. SECTION T104 MASTER TENT INSTALLER T104.1 Every individual who installs commercial tents greater than 200 square foot must be approved as a Master Tent Installer. T104.2 To become approved, the individual must: 1. Successfully complete a tent installation course approved by the Fire Code Official; 2. Successfully pass a no-cost written examination provided by the Fire Department, which will cover The Industrial Fabrics Association International (IFAI) Procedural Handbook for the Safe Installation & Maintenance of Tentage, the guidelines for the ballasting of tents commonly referenced as The Clemson Study within the industry, RSMo Chapter 310, the current Fire Code as adopted by the City of Springfield, and any other materials deemed appropriate by the Fire Code Official. Only those chapters that relate to tent safety will be covered, including but not limited to Chapter 31, exit lighting, fire extinguishers, etc.; 3. Hold a valid business license for the City of Springfield, or operate under the employ of a City of Springfield licensed Tent Vendor; and 4. Carry the minimum General Liability insurance required by the City for Master licenses, or operate under the employ of a City of Springfield licensed Tent Vendor providing the minimum General Liability insurance required. T104.3 The approval is valid for three years from the date of issuance, but may be revoked for cause. T104.4 An approved master tent installer must be on-site and directly oversee the installation of every commercial tent greater than 200 square foot in size. T104.5 Once the tent is installed, the master tent installer must sign the assurance statement on the permit, including emergency contact information, and securely fasten it in a conspicuous place within the tent. SECTION T105 TENT INSTALLATION T105.1 All commercial grade tents must be installed in accordance with one of the following: 1. Wind-rated tents: manufacturer's recommendations - documentation must be provided to the Fire Department. 2. Non-rated tents: manufacturer's recommendations that comply with the IFAI Procedural Handbook for the Safe Installation & Maintenance of Tentage - Manufacturer's recommendations must be provided to the Fire Department. 3. Non-rated tents: The IFAI Procedural Handbook for the Safe Installation& Maintenance of Tentage and the provisions contained within this code. 4. Non-rated tents: an engineered study by a professional engineer -engineered study must be provided to the Fire Department. (This is used when the manufacturer does not provide instructions and/or when the instructions for a non-wind rated tent conflict with the IFAI Procedural Handbook for the Safe Installation & Maintenance of Tentage.) SECTION T106 INSPECTIONS T106.1 All tents, ballasting, and tie-downs will be inspected for defects, wear and tear, and damage prior to the installation of each tent. Those with visible damage will not be erected. SECTION T107 STAKING T107.1 All stakes will be installed in accordance with The IFAI Procedural Handbook for the Safe Installation & Maintenance of Tentage. T107.2 Color Coding. All stakes will have the heads painted the following color to indicate the length of the stake in the following manner: i. Red: 32" - 39" ii. Yellow: >40" but not more than 47" iii. Green: 48" or more T107.3 Embedment. Regardless of actual length, stake embedment will be considered the following based upon color: iv. Red: 28 inches v. Yellow: 34 inches vi. Green: 36 inches T107.4 Maximum stake exposure. The maximum amount of stake exposed above the ground is: vii. Red: 4 inches viii. Yellow: 6 inches ix. Green: 12 inches T107.5 Tie downs. Tie downs/guys should be attached within 2 inches of the ground, and in no case, can be more than 4 inches from the ground, regardless of the amount of stake above ground. T107.6 Diameter. All stakes must be at least 1 inches in diameter. T107.7 Stakes are to be driven vertically between 0 and 15 degrees. T107.8 In no case will a stake be less than one-half the height of the upright and no more than the height of the upright from the leg, except as otherwise provided in this code. T107.9 If heads of stakes are unpainted, stakes will be presumed to be 32 inches (thirty-two inches) in length. SECTION T108 KNOTS T108.1 Only knots approved in the IFAI Procedural Handbook for the Safe Installation & Maintenance of Tentage will be used, unless the tent is wind-rated or is approved by an engineered study by a professional engineer. SECTION T109 BALLASTING T109.1 All tents will be ballasted either according to The Clemson Study provided by the IFAI or by an engineered study by a professional engineer. T109.2 Unless a tent is certified by its manufacturer as a wind-rated tent and documentation is provided, installations must meet the non-wind rated ballasting. T109.3 Concrete ballasts must be permanently marked with the weight of the block and must weigh at least 125 pounds. T109.4 No more than two ballasting blocks may be used to provide the required weight per leg/pole. When two ballasting blocks are used, they must use a load equalizing device. Effective January 1, 2016. T109.4.1 Exception: More than two ballasting blocks may be used when a connecting system approved by the Fire Code Official is used where they are positively locked so as to act as a single anchor. T109.5 Ballasting may not be accomplished by the use of containers using water to create the weight. SECTION T110 TIE-DOWNS, RATCHET STRAPS AND GUY ROPES T110.1 Requirements for tie downs, ratchet straps and ropes. T110.1.1 The working load of tie-downs will be rated as provided in The IFAI Procedural Handbook for the Safe Installation & Maintenance of Tentage. T110.1.2 The rated strength of tie-downs must meet or exceed twice the ballasting/staking required. T110.1.4 Ropes must be at least ½ inches in diameter. T110.1.5 Ratchet type straps must be clearly marked by the original manufacturer for the approved working load limit rating. T110.1.6 Ratchet straps must have a positive locking hook system to prevent it from accidentally becoming unsecured from the stake, grommet, or other securing device. SECTION T111 LEGS/ANCHOR POINTS T111.1 Every leg/anchor point must have the appropriate staking/ballasting. T111.2 All jump ropes must be properly secured. SECTION T112 TENSIONING T112.1 All non-wind rated tents must be anchored and tensioned to a minimum of 7.5 pounds per square foot of uplift loads and 5 pounds per square foot of lateral loads unless otherwise provided in this code. SECTION T113 ADDITIONAL REQUIREMENTS T113.1 The owner of the tent will provide all required safety items, including fire extinguishers, exit lighting, and other items required by this code or the Fire Code Official. T113.2 The owner of the tent will provide any heaters that are used within a tent and their use must be approved by the Fire Code Official. T113.3 Every tent must have the owner's name and contact information securely fastened in a conspicuous location on the tent. T113.4 Wind. Tents must be immediately evacuated when wind speeds or gusts are above 45 mph unless, except: T113.4.1.1 Tents that are erected for a period of 7 days or less and when wind speeds are predicted by the National Weather Service to be less than 45 mph from the time the tent is erected until it is set to be removed, and anchored and tensioned to the following as a minimum rather than Sections 3103.9.5(1) and 3103.9.8, shall be evacuated when wind speeds or gusts are above 30 mph. Ballasting | Without Sidewalls | With Sidewalls 100 sq. ft. or less | 4.5 lbs./sq. ft. | 14 lbs./sq. ft. >100 sq. ft. - 900 sq. ft. | 10.0 lbs./sq. ft. | 18 lbs./sq. ft. T113.4.1.2 Tents that are erected for a period of 7 days or less and when wind speeds are predicted by the National Weather Service to be less than 45 mph from the time the tent is erected until it is set to be removed and staked to the following as a minimum rather than Section V, paragraph 3h above. Staking | Without Sidewalls | * | With Sidewalls | * 100 sq. ft. or less | Red or unpainted | 1' | Yellow | 3' 101 sq. ft. to 400 sq. ft. | Yellow | 1' | Yellow | 3' * = Distance from tent. SECTION T114 CONSUMER SAFETY AWARENESS CONSULTATION T114.1 The owner, agent or installer shall review safety requirements, as per event specifics necessitate, with the event manager or end user of the tent or membrane structure. The consultation shall comply with sections T114.2 and T114.3. T114.2 A safety consultation shall be provided to the event manager or end user of the tent or membrane structure. The consultation shall be documented in written format and shall be signed by both the owner, agent or installer and the event manager or end user and must be provided to the fire code official upon request. Safety topics covered in the consultation shall include, but are not limited to, items 1 through 5 below: 1. Maximum occupancy load for each tent or membrane structure. 2. Interior layout. Placement of tables, chairs, stages, decorations or other physical elements with consideration for required aisle and exit widths which must remain unobstructed. 3. Heat sources. Safety requirements regarding cooking, heating, smoking and other open flames items. 4. Potential hazards associated with high winds and other severe weather conditions. 5. Emergency action plan as described in section T114.3. T114.3 An emergency action plan shall be developed specific to each event. The emergency action plan shall be documented in written format and shall be signed by both the owner, agent or installer and the event manager or end user and must be provided to the fire code official upon request. Items covered in the emergency action plan shall include, but are not limited to, items 1 through 4 below: 1. Identification of a crowd manager or person responsible for monitoring weather and other hazardous conditions and making notification for an evacuation of the tent(s) or membrane structure(s). 2. Effective and expedient means of crowd notification. 3. Identification of safe location and evacuation procedure. 4. Evacuation parameters including, but not limited to: i. wind speeds in excess of tent or membrane structure design and installation limits. ii. severe weather conditions such as tornado, earth quake, hail, lightning, flash flooding, etc. iii. fire or other hazardous condition posing a threat to occupants of the tent or membrane structure. iv. unstable or unsafe tent or membrane structure condition or partial collapse.
(G.O. No. 5078, § 2, 4-30-2001; G.O. 5090, § 1, 6-11-2001; G.O. No. 5155, § 1, 2-11-2002; G.O. No. 5163, §§ 1, 2, 2-25-2002; G.O. No. 5349, § 2, 1-26-2004; G.O. No. 5634, § 2, 12-11-2006; G.O. No. 5887, § 1, 8-23-2010; G.O. No. 5896, § 1, 9-20-2010; G.O. No. 5987, § 3(Exh. A), 3-26-2012; G.O. No. 6028, §§ 1—3, 1-14-2013; G.O. No. 6242, § 1(Exh. A), 11-23-2015; G.O. No. 6249, §§ 1, 2(Exh. A), 1-11-2016; G.O. No. 6463, § 3(Exh. A), 7-2-2018; G.O. No. 6509, §§ 1, 2(Exh. A), 3-11-2019; S.O. No. 27171, §§ 1, 2(Exh. A), 4-22-2019; G.O. No. 6606, § 1(Exh. A), 7-13-2020; G.O. No. 6673, § 1(Exh. A), 8-9-2021; G.O. No. 6674, § 1(Exh. A), 8-9-2021; G.O. No. 6675, § 1(Exh. A), 8-9-2021; G.O. No. 6699, § 1(Exh. A), 12-13-2021; G.O. No. 6810, § 1(Exh. A), 8-21-2023; G.O. No. 6903, § 1, 1-13-2025; G.O. No. 6972, § 2(Exh. A), 1-12-2026)
Ask a question about Springfield law
Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.
