§142.1010 General Loading Area Regulations
(a) Loading area requirements are provided in Table 142-10B. The number of required loading area spaces is based on the use of the building and the building size. Where two or more uses are located on the same premises, the number of loading area spaces required is the sum of the spaces required for each use (based on square footage of each use) computed separately. The City Manager may reduce these loading area requirements where the loading area is shared by the uses.
(b) Parking of passenger vehicles is not permitted in off-street loading areas.
(c) Each required off-street loading space shall have a minimum length of 35 feet, a minimum width of 12 feet, and a minimum vertical clearance of 14 feet including entrances and exits.
Table 142-10B Required Off-Street Loading Spaces
Use Category or Subcategory | Gross Floor Area of Structure (Square Feet) | Minimum Number of Spaces Required
Multiple Unit Residential Use Subcategory or Commercial Services Subcategories not specified or Industrial - Research and Development | 0-100,000 | 0
100,001-200,000 | 1
200,001-500,000 | 2
More than 500,000 | 3 - plus 1 space for each additional 400,000 sq. ft. of gross floor area
Retail Sales Use Category or Commercial Services - Eating and Drinking Establishments Subcategory | 0-10,000 | 0
10,000-30,000 | 1
30,000-50,000 | 2
Over 50,000 | 1 space per 25,000 sq. ft. of gross floor area
Commercial Services - Visitor Accommodations Subcategory | 0-40,000 | 1
Over 40,000 | 0.25 space per 10,000 sq. ft. of gross floor area
Office Use Category | 0-50,000 | 0
Over 50,000 | 0.1 space per 10,000 sq. ft. of gross floor area
Distribution and Storage Use Category or Industrial Use Category and Subcategories not specified | 0-10,000 | 0
10,001-50,000 | 1
Over 50,000 | 0.2 space per 10,000 sq.ft. of gross floor area
(Added 12-9-1997 by O-18451 N.S.; effective 1-1-2000.)
(Amended 11-13-08 by O-19805 N.S; effective 12-13-2008.)
(Amended 7-22-2024 by O-21836 N.S.; effective 10-5-2024.)