§ 3.2 — GLAZING AND FAÇADE RELIEF REQUIREMENTS
Austin City Code (Supp. No. 174: codified through Ordinance No. 20260521-050, effective June 1, 2026) · Austin City Code ch. 25-2, subch. E, § 3.2
Corpus is an independent public-information project, not the official City of Austin website. Stable reference: corpuslaw.us/code/41e37a85-fd7b-497f-9f9a-c25c7e76835b
§ 3.2. - GLAZING AND FAÇADE RELIEF REQUIREMENTS.
3.2.1. Applicability. The following table summarizes the applicability of this section: Standard | Applies if the Principal Street Is: | Applies to the Following: 3.2. Glazing and Façade Relief Requirements | All roadway types | - Development of any non-residential land use, except for congregate care facilities zoned MF for which the principal street is not a Core Transit Corridor - Religious Assembly use shall be exempt from glazing requirements. 3.2.2. Glazing and Façade Relief on Building Façades. Glazing provides interest for pedestrians, connects the building exterior and interior, puts eyes on the street, promotes reusability, and provides a human-scale element on building façades. Projects subject to this section shall meet the following minimum requirements, but may provide additional glazing and façade relief beyond what is required under this section. Refer to Article 5 for definitions of Glazing and Façade Relief. A. On the façade facing the roadway or Internal Circulation Route where building frontage is provided under the requirements of this Subchapter: 1. 40 percent of the wall area below ten feet as measured from the finish floor level of this façade's entry shall consist of glazing unless topography, distance or other physical characteristics remove the façade from a close physical connection to the roadway or Internal Circulation Route (See Figure 39.); and (See Figure 39 set forth in Exhibit A attached to Ord. 20130606-088; Glazing and façade relief requirements) 2. 25 percent of the wall area between ten feet and thirty feet as measured from the finish floor level of this façade's entry shall consist of glazing. (See Figure 39.) B. One façade shall be exempt from glazing and façade relief requirements. The exempt façade cannot face a public street or Internal Circulation Route. C. On all other façades, at least 25 percent of the wall area between two and ten feet as measured from the finish floor level of this façade's entry must consist of glazing or façade relief unless vegetative screening, which must be evergreen, is allowed if approved by the Director, and may not be used as glazing option on front-facing façade. D. Any façade that is built up to an interior mid-block property line is not required to have glazing on that façade if no prohibitions and no contractual or legal impediments exist that would prevent a building being constructed on the adjacent property up to the wall of the façade. E. At least one-half of the total area of all glazing on façades that face the principal street shall have a Visible Transmittance (VT) of 0.6 or higher. F. The requirements in this section may be reduced to the extent that the required level or location of glazing conflicts with the standards of the Adopted Energy Code, Building Code, LEED, or the Green Building Program.
Source: Ord. 20060831-068; Ord. 20100408-049; Ord. 20121018-024; Ord. 20130606-088.
Ask a question about Austin law
Corpus searches the Austin sections it holds and shows the ones that match, with their citations. Free, no sign-in.
