Old City Height Districts.
Charleston, S.C., Zoning Ordinance § 54-306
in effectSec. 54-306. - Old City Height Districts.
The requirements of this section have resulted from a contextual study of building height and architectural patterns in the Old City Height District. The requirements of this section reflect the predominant building height trends of the areas to which they are applied, and reinforce the principles cited in the Downtown Plan, adopted in 1999, that higher structures be located along spine streets of the Peninsula, with heights of structures tapering down towards the waters' edges. The requirements of this Section are intended to clarify acceptable heights of buildings in areas of the Old City Height District, subject to the right of the Board of Architectural Review to adjust heights in limited circumstances when based on architectural merit and context.
General requirements:
1. Heights shall be measured in stories or feet, as specified. Notwithstanding the foregoing, height shall be measured in feet in the following districts: 3X, 85/200, 85/125, 85/30, 100/30, 80/30, 55/30S, 55/30, 56/30V, 120/30, 50W, W and WP.
2. For maximum height specified in feet, the measurement shall be taken from the highest curb elevation adjacent to the site to the highest point of the structure. Where heights are specified in stories, the measurement shall be taken from finished floor to finished floor.
3. Notwithstanding Sec. 54-306 (5), new principal buildings within a VE or AE zone on the Flood Insurance Rate Map may have 2 stories over a first-floor structure that exceeds 6' in height, provided the first floor elevation does not exceed the elevation required to meet FEMA and City freeboard requirements.
4. If a building is required to be raised per FEMA requirements, that same height shall be added to the maximum height allowed, up to a maximum of six (6) feet. This measurement shall be taken from the highest curb elevation.
5. Existing structures shall be allowed to be elevated to meet FEMA and City freeboard requirements and exceed height limitations of this Chapter.
6. Any area under a structure in excess of six feet shall be counted as a story.
7. The BAR is empowered to require a downward adjustment of one-half story in the number of stories from the permitted number of stories in the applicable height district based on the predominate number of stories in the structure's immediate surroundings, as defined in Section 54-231.
8. Floors shall be measured in the following manner:
Residential:
a. The maximum height of any residential floor shall be 12 feet The BAR may grant a waiver up to 14 feet on the first or second floor, based on architectural merit and context. Any dimension above this shall constitute two stories.
b. The minimum height of any residential floor shall not be less than 10 feet; however, there is no minimum height for floors in a one family dwelling , two family dwelling or one family attached dwelling .
c. The BAR is empowered to require adjustments to floor heights, based on context of the structure with its immediate surroundings, as defined in Section 54-231.
Non-Residential:
d. The maximum height of any nonresidential story shall be 20 feet. The BAR may grant a waiver up to 25 feet on the main floor based on architectural merit and context. Any dimension above this height shall constitute two stories.
e. The minimum height of any nonresidential floor shall not be less than 12 feet, unless otherwise specified in Sec. 54.306.X.
f. The BAR is empowered to require adjustments to floor heights, based on context of the structure with its immediate surroundings, as defined in Section 54-231 H.
9. Half stories, as the top story of a building, shall be permitted as specified by height district, subject to the following restrictions.
For the purposes of this section, half stories on one-family dwellings, two-family dwellings, one-family attached dwellings, and accessory buildings to these building types within the Old City Height Districts shall be limited the space under a gable or hipped roof where the wall plates, or knee walls, on at least two opposite exterior walls shall not exceed two feet in height. The aggregate width of dormers on a half story shall not exceed 30% of the width of the exterior wall below the dormer(s).
Notwithstanding the definition for half story in Sec. 54-120, for purposes of this section, half stories on all other types of buildings may be either:
a. A full story with a total floor area, including any covered exterior floor area under a roof, that does not exceed 50% of the conditioned floor area of the story immediately below the half story as illustrated in Figure 1 below, or
b. A half story under a gable or hipped roof that complies with the restrictions for a half story on a one or two family dwelling described in the previous paragraph
Figure 1
[image omitted; see the official code]
10. Building height to roof eave shall not exceed twice the building width of the primary façade of habitable space fronting the street as illustrated in Figure 2 below; provided the Board of Architectural Review may waive this provision based on architectural merit and context.
Figure 2
[image omitted; see the official code]
11. There shall be no minimum building height requirement, unless required by the applicable height district as specified in Sectiohn 54-306.X.
12. If any portion of a structure subject to the jurisdiction of the BAR is within fifty (50) feet of an existing structure rated "exceptional" (Group 1) or "excellent" (Group 2) on the Historic Architecture Inventory, adopted by Section 54-235, or a structure in the Landmark Overlay district, such portion of that structure shall not exceed the height of such existing structures unless approved by the Board of Architectural Review based on architectural merit and context.
13. Additional buildings and additions to buildings that are subject to the jurisdiction of the BAR shall be subordinate in height, scale and mass to the primary building; provided this provision may be waived by the Board of Architectural Review when it deems such appropriate based on architectural merit and context or existing lot conditions. This provision does not apply to vertical additions to existing buildings. When appropriate, vertical additions must strive to be minimally visible with minimal impact on the character of the historic building and its context.
14. Parking garages shall not exceed the height of the principal building on the site. Parking garages shall not be constrained by floor to floor height requirements, but stand-alone parking garages shall appear from the street to conform to the number of stories permitted in the height district in which it is located.
15. In the height districts where additional height may be awarded on the basis of architectural merit and context, if the property is not subject to the jurisdiction of the Board of Architectural Review, the owner requesting the additional height must submit the plans to the Board of Architectural Review for review and approval. The property will not remain subject to the Board of Architectural Review purview after the request for additional height is reviewed. Any further request for additional height will trigger review by the Board of Architectural Review.
16. An applicant seeking a height rezoning shall only be able to request a rezoning to the next higher height district, except for applicants seeking a rezoning to the Upper Peninsula Zoning district. Requests to rezone to a higher height district shall be evaluated, in part, on the context of the property, the character of the immediate area, street widths around the property, and whether the requested rezoning will be compatible with surrounding properties.
17. Standalone Communication towers shall not exceed the maximum building height limits of districts that include a maximum height limit in feet, or a height limit equal to 14 feet per story for districts that are specified in stories.
18. "Architectural merit" means a project that reflects exemplary architectural and urban design, utilizes the highest level of materials and finishes and contributes to the public realm, as outlined in the Board of Architectural Review Principles.
19. Additional height for ornamental appurtenances and utilitarian appurtenances related to mechanical equipment or structural systems (such as elevator and stair towers, exhaust fans, HVAC and communication equipment) that exceed the maximum allowable height may be permitted by the Board of Architectural Review, based on architectural merit and context.
20. Appurtenances shall not exceed nine (9) feet and shall be placed to the rear of side of a building where possible in order to minimize visibility from the public right of way.
21. Mechanical equipment on a roof shall be visually screened from the street with parapets or other types of visual screens of the minimum height necessary to conceal the same. Density of screening should be adequate to sufficiently screen mechanical equipment.
(Ord. No. 2001-62, § 1, 6-19-02; Ord. No. 2003-07, §§ 1, 2, 1-14-03; Ord. No. 2004-25, § 2, 3-9-04; Ord. No. 2004-89, § 1, 9-14-04; Ord. No. 2004-94, § 1, 9-14-04; Ord. No. 2007-172, §§ 3, 4, 9-11-07; Ord. No. 2008-139, §§ 1—3, 10-28-08; Ord. No. 2014-32, § 1, 3-18-14; Ord. No. 2014-153, § 2, 12-2-14; Ord. No. 2015-140, § 1, 10-13-2015; Ord. No. 2017-085, § 1, 8-15-17; Ord. No. 2020-014, § 1, 1-28-20; Ord. No. 2021-014; Ord. No. 2021-014, § 1, 2-9-21; Ord. No. 2022-181, § 1, 12-6-22)
Source: City of Charleston, South Carolina, Code of Ordinances and Zoning Ordinance (Municode Library, library.municode.com)URL: https://library.municode.com/sc/charleston/codes/zoning?nodeId=ART3SIRE_PT2OLHEDIVICOPR_S54-306OLHEDIFetched: 11/7/2026