§ 30.1-0102 — Amendment to International Fuel Gas Code
Fargo Municipal Code, Fargo, North Dakota (Supp. No. 14, Update 5: codified through Ordinance No. 5555, adopted August 17, 2026) · Fargo Municipal Code § 30.1-0102
Corpus is an independent public-information project, not the official City of Fargo website. Stable reference: corpuslaw.us/code/44fcc6ac-fdc2-4e26-804f-4902fa8413c9
30.1-0102. - Amendment to International Fuel Gas Code.
The International Fuel Gas Code as adopted in Section 30.1-0101 is hereby changed and amended as follows: Section 101.1 is hereby amended to read as follows: 101.1 Title. These regulations shall be known as the Fuel Gas Code of the City of Fargo, hereinafter referred to as "this code." Section 104.8 is hereby amended to read as follows: 104.8 Liability. The code official, member of the board of appeals or employee charged with the enforcement of this code, while acting for the jurisdiction in good faith and without malice in the discharge of the duties required by this code or other pertinent law or ordinance, shall not thereby be rendered personally liable, either civilly or criminally, and is hereby relieved from personal liability for any damage accruing to persons or property as a result of an act or by reason of any act or omission in the discharge of official duties. This code shall not be construed to relieve from or lesson the responsibility of any person owning, operating, or controlling any building or structure for any damage to persons or property caused by defects nor shall the code enforcement agency or the city be held as assuming any such liability by reason of the inspection authorized by this code or any permits or certificates issued under this code. Section 108.2 is hereby amended to read as follows: 108.2 Schedule of permit fees. Where work requires a permit, a fee for each permit shall be paid as required, in accordance with the schedule as established by the City of Fargo Board of City Commissioners. Section 201.3 is hereby amended to read as follows: 201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the International Building Code, International Fire Code, International Mechanical code or North Dakota State Plumbing Code, such terms shall have meanings ascribed to them as in those codes. Section 304.6.1 is hereby amended to read as follows: 304.6.1 Two-permanent-openings method. * * * * Where directly communicating with the outdoors, or where communicating with the outdoors through vertical ducts, each opening shall have a minimum free area of 1 square inch per 4,000 Btu/h (550 mm2 /kW) of total input rating of all appliances in the enclosure. * * * * Figure 304.6.1(1) is hereby deleted in its entirety. Figure 304.6.1(2) is hereby deleted in its entirety. Figure 304.6.2 is hereby amended as shown below: [image omitted; see the official code] Section 304.6.2 is hereby amended to read as follows: 304.6.2 One-permanent-opening method. One permanent opening, commencing within 12 inches (305 mm) of the top of the enclosure, shall be provided. The appliance shall have clearances of not less than 1 inch (25 mm) from the sides and back and 6 inches (152 mm) from the front of the appliance. The opening shall directly communicate with the outdoors, or through a vertical or horizontal duct, to the outdoors and shall have a minimum free area of 1 square inch per 3,000 Btu/h (734 mm 2 /kW) of the total input rating of all appliances located in the enclosure and not less than the sum of the areas of all vent connectors in the space. Section 304.11 is hereby amended to read as follows: 304.11 Combustion air ducts. Combustion air ducts shall comply with all of the following: * * * * 5. Ducts shall not terminate in an attic space. * * * * Section 406.4 is hereby amended to read as follows: 406.4 Test pressure measurement. Test pressure shall be measured with a manometer or with a pressure-measuring device designed and calibrated to read, record or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Dial gauges used to measure test pressures shall be performed with gauges of 2-psi incrimination or less and have a range not exceeding 100 psi unless otherwise approved. Section 406.4.1 is hereby amended to read as follows: 406.4.1 Test pressure. The test pressure to be used shall be not less than 1 ½ times the proposed maximum working pressure, but not less than 25 psig irrespective of design pressure. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe. Section 408.2 is hereby amended to read as follows: 408.2 Drips. Where wet gas exists, a drip shall be provided at any point in the line of pipe where condensate could collect. Section 411.2 is hereby amended to read as follows: 411.2 Manufactured home connections. Manufactured homes shall be connected to the distribution piping system by listed and labeled connectors in compliance with ANSI Z21.75/CSA 6.27 and installed in accordance with the manufacturer's instructions. Section 501.12 is hereby amended to read as follows: 501.12 Residential and low-heat appliances flue lining systems. Flue lining systems for use with residential-type and low-heat appliances shall be limited to the following: 1. Clay flue lining complying with the requirements of ASTM C315 or equivalent when each appliance connected into the masonry chimney has a minimum input rating greater than 400,000 Btu/h. Clay flue lining shall be installed in accordance with the International Building Code. 2. Listed chimney-lining systems complying with UL 1777. 3. Other approved materials that will resist, without cracking, softening or corrosion, flue gases and condensate at temperatures up to 1,800°F (982°C).
Source: 5351 (2022), 5490 (2025).
Ask a question about Fargo law
Corpus searches the Fargo sections it holds and shows the ones that match, with their citations. Free, no sign-in.