Effluent limitations attainable by the application of the best available technology economically achievable (BAT).
40 C.F.R. § 432.123
in effectExcept as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart that further processes more than 7 million pounds per year (in units of finished product) must achieve the following effluent limitations representing the application of BAT:
Effluent Limitations
[BAT]
Regulated
parameter
Maximum daily
1
Maximum monthly avg.
1
Ammonia (as N)8.04.0
Total Nitrogen147103