Sec. 262. - Flood resistant development; site improvements, utilities and limitations.

(1) Minimum requirements. All proposed new development shall be reviewed to determine that: (a) Such proposals are consistent with the need to minimize flood damage and will be reasonably safe from flooding; (b) All public utilities and facilities such as sewer, gas, electric, communications, and water systems are located and constructed to minimize or eliminate flood damage; and (c) Adequate drainage is provided to reduce exposure to flood hazards: in Zones AH and AO, adequate drainage paths shall be provided to guide floodwaters around and away from proposed structures. (2) Sanitary sewage facilities. All new and replacement sanitary sewage facilities, private sewage treatment plants (including all pumping stations and collector systems), and on-site waste disposal systems shall be designed in accordance with the standards for onsite sewage treatment and disposal systems in Chapter 64E-6, Florida Administrative Code and ASCE 24 Chapter 7 to minimize or eliminate infiltration of floodwaters into the facilities and discharge from the facilities into flood waters, and impairment of the facilities and systems. (3) Water supply facilities. All new and replacement water supply facilities shall be designed in accordance with the water well construction standards in Chapter 62-532.500, Florida Administrative Code and ASCE 24 Chapter 7 to minimize or eliminate infiltration of floodwaters into the systems. (4) Limitations on sites in regulatory floodways. No development, including but not limited to site improvements, and land disturbing activity involving fill or regrading, shall be authorized in the regulatory floodway unless the floodway encroachment analysis required in section 256(3)(a) of this article demonstrates that the proposed development or land disturbing activity will not result in any increase in the base flood elevation. (5) Limitations on placement of fill. Subject to the limitations of this article, fill shall be designed to be stable under conditions of flooding including rapid rise and rapid drawdown of floodwaters, prolonged inundation, and protection against flood-related erosion and scour. In addition to these requirements, if intended to support buildings and structures (Zone A only), fill shall comply with the requirements of the Florida Building Code and: (a) Shall extend laterally at least five (5) feet beyond the building line from all points, at a maximum slope downward of two (2) inches in twelve (12) inches horizontally and beyond the five-foot fill zone, fill slopes may be increased to six (6) inches vertical in twelve (12) inches horizontal. (b) Steeper slopes or retaining walls may be constructed upon application to and approval of the floodplain administrator.

(Ord. No. 2014-113, § 3, eff. 6-18-14)

Ask a question about Coral Springs law

Corpus searches the Coral Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.