15.44.020 - Code amended.
The City of Henderson adopts as an amendment to the 2024 International Swimming Pool and Spa Code the booklet entitled "Southern Nevada Amendments to the 2024 International Swimming Pool and Spa Code." This booklet is adopted in its entirely, excepting amendments and changes as stated in this chapter. This booklet is available on the city's website(s).
The booklet is further amended by deleting Section 305.4 and replacing it as follows:
Section 305.4 Structural Wall as a Barrier.
305.4 Structure wall as a barrier. Where a wall of a dwelling or structure serves as part of the barrier and where doors, pet doors that allow a 4-inch diameter sphere to pass through, gates or windows provide direct access to the pool or spa through that wall, one of the following shall be required:
1. Operable windows having a sill height of less than 48 inches (1219 mm) above the indoor finished floor, doors, pet doors, and gates, shall have an alarm that produces an audible warning when the window, door or their screens are opened. The alarm shall be listed and labeled as a water hazard entrance alarm in accordance with UL 2017.
2. In dwellings not required to be Accessible units, Type A units or Type B units, the operable parts of the alarm deactivation switches shall be located at not less than 54 inches (1372 mm) above the finished floor.
3. In dwellings that are required to be Accessible units, Type A units or Type B units, the operable parts of the alarm deactivation switches shall be located not greater than 54 inches (1372 mm) and not less than 48 inches (1219 mm) above the finished floor. Windows shall be equipped with a permanent locking device to prevent an opening such that a sphere of 4 inches (102 mm) in diameter cannot pass through.
4. In structures other than dwellings, the operable parts of the alarm deactivation switches shall be located not greater than 54 inches (1372 mm) and not less than 48 inches (1220 mm) above the finished floor. Windows shall be equipped with a permanent locking device to prevent an opening such that a sphere of 4 inches (102 mm) in diameter cannot pass through.
5. A safety cover that is listed and labeled in accordance with ASTM F1346 is installed for the pools and spas.
6. An approved means of protection, such as self-closing doors with self-latching devices, is provided. Such means of protection shall provide a degree of protection that is not less than the protection afforded by Item 1 or 2.
7. Windows serving as part of a required means of egress that are unable to be equipped with a permanent locking device shall not be included in a public pool or spa barrier.
(Ord. No. 4139, § 2, 12-16-2025; Ord. No. 4091, § 1, 7-15-2025; Ord. No. 3511, § 1, 8-7-2018; Ord. No. 3045, § 1, 8-6-2013)