For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 33.218.110 — Standards for Primary and Attached Accessory Structures in RM1, RM2, and RMP Zones

Portland City Code (non-zoning titles; Title 33 separately); partial · Portland Zoning Code § 33.218.110

Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/481f8cde-4f77-4532-8741-c6fc7441d277

33.218.110 Standards for Primary and Attached Accessory Structures in RM1, RM2, and RMP Zones

The standards of this section apply to development of new primary and attached accessory structures in the RM1, RM2, and RMP zones. The addition of an attached accessory structure to a primary structure on a site where all the uses are residential, is subject to Section 33.218.130, Standards for Exterior Alteration of Residential Structures in Single-Dwelling, RM1, RM2, and RMP Zones. The standards of this section can also apply to development of new structures in the RM3, RM4, RX, C and E zones on sites where all the uses are residential. In this case, the applicant can choose to meet all the standards in this section or all the standards in Section 33.218.140, Standards for all Structures in the RM3, RM4, RX, C and E Zones. A. Landscaping. Landscaping must be provided between structures and the street, as follows: 1. Foundation landscaping. All street-facing elevations must have landscaping along their foundation. The landscaped area may be along the outer edge of a porch instead of the foundation. This landscaping requirement does not apply to portions of the building facade that provide access for pedestrians or vehicles to the building. The foundation landscaping must meet the following standards: a. The landscaped area must be at least 3 feet wide; b. There must be at least one three-gallon shrub for every 3 lineal feet of foundation; and c. Ground cover plants must fully cover the remainder of the landscaped area. 2. Front yard trees. There must be at least one tree in front of each residential structure. On corner lots, there must be one tree for each 30 feet of frontage on the side street. B. Building setback. Primary buildings must not be set back from the front lot line more than 25 feet. C. Residential buffer. Where a site zoned RM2, RM3, RM4, RX, or E abuts or is across a street from an RF through RM1 or RMP zone, the following is required. Proposals in the Hollywood, Kenton, and Sandy plan districts are exempt from this standard: 1. On sites that abut an RF through RM1 or RMP zone the following must be met: a. In the portion of the site within 25 feet of the lower density residential zone, the building height limits are those of the adjacent residential zone; and b. A 10 foot deep area landscaped to at least the L3 standard must be provided along any lot line that abuts the lower density residential zone. 2. On sites across the street from an RF through RM1 or RMP zone the following must be met: a. On the portion of the site within 15 feet of the intervening street, the height limits are those of the lower density residential zone across the street; and b. If the site is across a local service street from an RF through RM1 or RMP zone, a 5-foot deep area landscaped to at least the L2 standard must be provided along the property line across the local service street from the lower density residential zone. Vehicle access is not allowed through the landscaped area unless the site has frontage only on that local service street. Pedestrian and bicycle access is allowed, but may not be more than 6 feet wide. D. Building height. Except as provided in Subsection C, above, structures in the RM3, RM4, RX, and E zones may be up to 55 feet in height. E. Large building elevations divided into smaller areas. The front elevation of large structures must be divided into smaller areas or planes. When the front elevation of a structure is more than 750 square feet in area, the elevation must be divided into distinct planes of 500 square feet or less. For the purpose of this standard, areas of wall that are entirely separated from other wall areas by a projection, such as the porch or a roof over a porch, are also individual building wall planes. This division can by done by: 1. A porch, a dormer that is at least 4 feet wide, or a balcony that is at least 2 feet deep and is accessible from an interior room; 2. A bay window that extends at least 2 feet; or 3. Recessing a section of the facade by at least 2 feet; the recessed section must be at least 6 feet long. F. Roofs. Primary structures must have either: 1. A sloped roof with a pitch that is no flatter than 6/12 and no steeper than 12/12; or 2. A roof with a pitch of less than 6/12 if either: a. The space on top of the roof is used as a deck or balcony that is no more than 150 square feet in area and is accessible from an interior room; or b. A cornice that meets the following: (1) There must be two parts to the cornice. The top part of the cornice must project at least 6 inches from the face of the building and be at least 2 inches further from the face of the building than the bottom part of the cornice. See Figure 218-3; and (2) The height of the cornice is based on the height of the building as follows: • Buildings 10 feet or less in height must have a cornice at least 12 inches high. • Buildings greater than 10 feet and less than 30 feet in height must have a cornice at least 18 inches high. • Buildings 30 feet or greater in height must have a cornice at least 24 inches high. Figure 218-3 Two-Part Cornice

![](https://figures.74-208-44-221.nip.io/portland/20261114/8902d6817e2b81048d8c95da1610a2095b87c72e035081f811f9b8480e9fe1b9.png)

![Figure 218-3 Two-Part Cornice](https://figures.74-208-44-221.nip.io/portland/20261114/846b957f4cfc77794603ef465cb27ce74bb2e2a846ad85362b6bf1076c8b72ef.png)

G. Main entrance. 1. Location of main entrance. The main entrance of each primary structure must face the street lot line. The following are exceptions to this standard: a. On corner lots the main entrance may face either of the streets or be oriented to the corner. b. For buildings that have more than one main entrance, only one entrance must meet this requirement. c. Entrances that face a shared landscaped courtyard, landscaped to at least the L1 General Landscaping standard, are exempt from this requirement. 2. Front porch at main entrance. There must be a front porch at all main entrances that face the street. If the porch projects out from the building it must have a roof. If the roof of a required porch is developed as a deck or balcony it may be flat. If the main entrance is to a single dwelling, the covered area provided by the porch must be at least 6 feet wide and 4 feet deep. If the main entrance is to more than one dwelling unit, the covered area provided by the porch must be at least 9 feet wide and 7 feet deep. 3. Covered balcony. Attached houses have the option of providing a covered balcony on the same facade as the main entrance instead of a front porch. The covered area provided by the balcony must be at least 48 square feet, a minimum of 8 feet wide and no more than 15 feet above grade. The covered balcony must be accessible from the interior living space of the house. 4. Ornamental columns. If the front porch or covered balcony at a main entrance provides columns as corner supports, the columns must be ornamental columns that meet one of the following standards. Wrought iron style porch supports do not meet this standard: a. Large columns that are divided visually into clear areas of top, center, and bottom. Large rectilinear columns are at least 8" x 8", large rounded columns have a diameter of at least 8 inches; or b. Groupings of 2, 3, or 4 small columns that are divided visually into clear areas of top, center, and bottom. Small rectilinear columns are at least 4" x 4", small rounded columns have a diameter of at least 4 inches. 5. Openings between porch floor and ground. Opening of more than 1 foot between the porch floor and the ground must be covered with a solid material or lattice. H. Vehicle areas 1. Alleys. If the site is served by an alley, access for motor vehicles must be from the alley, not from a street frontage. 2. Vehicle areas between the building and the street. There are no vehicle areas allowed between the building and the street. If a site has two street lot lines, this standard must be met on both frontages. If a site has more than two street lot lines, this standard must be met on two frontages. An exception is allowed for single dwelling developments. Each dwelling unit in a single dwelling development is allowed one 9 foot wide driveway. 3. Parking areas in the front setback. Parking areas may not be located in the front setback. 4. Attached garages. When parking is provided in a garage attached to the primary structure and garage doors face a street the following standards must be met: a. The garage must not be more than 40 percent of the length of the building frontage or 12 feet long, whichever is greater; b. The front of the garage can be no closer to front lot line than the front facade of the house; c. Garage doors that are part of the street-facing elevations of a primary structure may be no more than 75 square feet in area; and d. There may be no more than one garage door per 16 feet of building frontage. 5. Driveways. Driveways for attached houses must meet the following. See Figures 218-1 and 218-2 for examples of driveways that meet the standard. a. Driveways may be paired so that there is a single curb-cut providing access to two attached houses. The maximum width allowed for the paired driveway is 18 feet; and b. There must be at least 18 feet between single or paired driveways. Distance between driveways is measured along the front property line. I. Foundation material. Plain concrete block or plain concrete may be used as foundation material if the foundation material is not revealed more than 3 feet above the finished grade level adjacent to the foundation wall. J. Exterior finish materials. The standards of this subsection must be met on all building facades. 1. Plain concrete block, plain concrete, corrugated metal, plywood, composite materials manufactured from wood or other products, and sheet pressboard may not be used as exterior finish material except as secondary finishes if they cover no more than 10 percent of each facade. 2. Composite boards manufactured from wood or other products, such as hardboard or hard plank, may be used when the board product is less than 6 inches wide. 3. Where wood products are used for siding, the siding must be shingles, or horizontal siding, not shakes. 4. Where horizontal siding is used, it must be shiplap or clapboard siding composed of boards with a reveal of 6 inches or less, or vinyl or aluminum siding which is in a clapboard or shiplap pattern where the boards in the pattern are 6 inches or less in width. 5. Siding material may not cover required window and door trim. K. Windows. Street-facing windows must meet the following. Windows in rooms with a finished floor height 4 feet or more below grade are exempt from this standard: 1. Each window must be square or vertical; 2. A horizontal window opening may be created when: a. Two or more vertical windows are grouped together to provide a horizontal opening, and they are either all the same size, or no more than two sizes are used. Where two sizes of windows are used in a group, the smaller window size must be on the outer edges of the grouping. The windows on the outer edges of the grouping must be vertical; the center window or windows may be vertical, square, or horizontal; or b. There is a band of individual lites across the top of the horizontal window. These small lites must be vertical and cover at least 20 percent of the total height of the window. 3. St. Johns plan district. In the St. Johns plan district, at least 15 percent of the street facing facade must be windows. Windows used to meet this standard must allow views from the building to the street. Glass block does not meet this standard. Windows in garage doors do not count toward meeting this standard, but windows in garage walls do count toward meeting this standard. Development on flag lots or on lots that slope up or down from the street with an average slope of 20 percent or more is exempt from this standard. L. Trim. Trim must mark all building roof lines, porches, windows and doors on all elevations. The trim must be at least 3-1/2 inches wide. Buildings with an exterior material of stucco or masonry are exempt from this standard. M. Roof-mounted equipment. All roof-mounted equipment, including satellite dishes and other communication equipment, must be screened in one of the following ways. Solar energy systems are subject to Subsection N below, and exempt from this standard: 1. A parapet as tall as the tallest part of the equipment; 2. A screen around the equipment that is as tall as the tallest part of the equipment; 3. The equipment is set back from the street-facing perimeters of the building 4 feet for each foot of height of the equipment; or 4. If the equipment is a satellite dish or other communication equipment, it is added to the facade of a penthouse that contains mechanical equipment, is no higher than the top of the penthouse, is flush mounted, and is painted to match the facade of the penthouse. N. Rooftop solar energy systems. 1. Rooftop solar energy systems must meet the following requirements: a. On a flat roof. The solar energy system must be mounted flush or on racks, with the system or rack extending no more than 5 feet above the top of the highest point of the roof, not including the parapet. Solar energy systems must also be screened from the street by: (1) An existing parapet along the street-facing facade that is as tall as the tallest part of the solar energy system; or (2) Setting the solar energy system back from the street-facing roof edges. For each foot of height that the portion of the system projects above the parapet, or roofline when there is no parapet, the system must be set back 4 feet. b. On a pitched roof. The plane of the system must be parallel with the roof surface, with the system no more than 12 inches from the surface of the roof at any point, and set back 3 feet from the roof edge and ridgeline. 2. Photovoltaic roofing shingles or tiles may be directly applied to the roof surface. 3. Photovoltaic glazing may be integrated into windows or skylights. O. Exterior stairs and fire escapes. Exterior stairs, other than those leading to a main entrance, must be at least 40 feet from all streets. Fire escapes must be at least 40 feet from all streets. P. Roof eaves. Roof eaves must project from the building wall at least 12 inches on all elevations. Buildings that take advantage of the cornice option are exempt from this standard. Q. Water cisterns. Above-ground cisterns for rainwater or greywater collection must meet the following: 1. Cisterns with a capacity of more than 80 gallons, or racks of cisterns with a total capacity of more than 80 gallons, may not be attached to the front facade of the primary structure; and 2. Cisterns must either: a. Match the color of the adjacent building wall, the color of the trim, or the color of the rain gutter; or b. Be screened by development, plantings, or fences so they are not visible from the street. R. Additional standards for historic resources. The following standards are additional requirements for conservation districts and conservation landmarks. 1. Skylights. Skylights may not be on street-facing elevations. On all other elevations, the glass, plastic, or other transparent material must be parallel to the slope of the roof. 2. Ornamental columns. Corners of the porch roof on street-facing elevations must be supported with ornamental columns that meet one of the following standards. Wrought iron style porch supports do not meet this standard: a. Large columns that are divided visually into clear areas of top, center, and bottom. Large rectilinear columns are at least 8" x 8", large rounded columns have a diameter of at least 8 inches; or b. Groupings of 2, 3, or 4 small columns that are divided visually into clear areas of top, center, and bottom. Small rectilinear columns are at least 4" x 4", small rounded columns have a diameter of at least 4 inches. 3. Roof dormers and gable areas in the Albina and Outer Southeast Community Plan areas. In the Albina and Outer Southeast Community Plan areas, shown on Maps 825- 1 and 825-2, each residential structure must have one of the following for every 40 feet of length along the street-facing elevations. Buildings with flat roofs are exempt from this standard: a. A street-facing roof dormer placed at least 3 feet from all side building walls; or b. A gable end facing the front lot line with either of the following in the gable area above the eave line: (1) A window; or (2) A trimmed vent. The trim must match the trim on the windows and the vent must be at least 4 square feet in area. 4. Albina Community Plan area. The standards of this paragraph apply in the Albina Community Plan area, shown on Map 825-1: a. Floor level delineation. Each primary residential structure must reflect, on its street-facing elevations, all floor levels in the building, including the attic. The different floor levels must be delineated through the use of porch roofs, changes in materials or texture of materials, location of pediment and roof lines, overhangs and setbacks. b. Ground floor. The ground floor of a primary structure that is entirely above grade must be at least 2 feet above grade. Developments must meet the standards of Chapter 11, Accessibility, of the Oregon Structural Specialty Code. 5. Stone or cast stone foundations in Kenton and Mississippi. In the Kenton and Mississippi Avenue Conservation Districts, stone or cast stone must be used as a foundation material on street-facing elevations. The stone, cast stone, or cast in place stone must be the material used between the finished building grade and the ground floor. 6. Vertical building proportions in Eliot. In the Eliot Conservation District, the front facade of each primary structure must have vertical proportions. New development must meet one of the following standards: a. It must be higher than it is wide; or b. Where the size of the building requires horizontal proportions, the street-facing elevations must be divided into visually distinct areas with vertical proportions. This is accomplished through setbacks, use of vertical elements such as columns or multi-story bay windows, changes in materials or other architectural devices. 7. Woodlawn street pattern. Buildings may not be in the vacated portions of the angled street pattern in the Woodlawn Conservation District. 8. Rooftop solar energy systems. a. Rooftop solar energy systems must not increase the footprint of the structure, must not increase the peak height of the roof, and the system must be parallel to the slope of the roof; b. Solar energy systems may not be installed on a conservation landmark. 9. Cisterns. Cisterns for rainwater or greywater collection may not be located closer to the street than the primary street facing building facade and they must be screened by development, fences, or plantings so they are not visible from the street. 10. Photovoltaic glazing, roofing shingles, or tiles may not be installed on a conservation landmark.

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.