IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H105.1, GENERAL REQUIREMENTS, ADD EXCEPTION
Boise City Code § 9-1A-70
in effect9-1A-70: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H105.1, GENERAL REQUIREMENTS, ADD EXCEPTION:
H105.1 General Requirements. Signs shall be designed and constructed to comply with the provisions of this code for use of materials, loads, and stresses.
Exception: Where Chapter 17 Special Inspections and Tests requires periodic special inspections for all post-installed concrete anchors, installation of signs utilizing these types of anchors will be considered minor in nature and not require periodic special inspection when acting primarily in shear and utilizing less than 50% of the allowable loading when tested in accordance with ACI 318.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
Source: Boise City, Idaho, City Code and City Charter (American Legal Publishing, codelibrary.amlegal.com)URL: https://codelibrary.amlegal.com/codes/boise_id/latest/boise/0-0-0-36990Fetched: 11/1/2026