Sec. 68.164. - Standards for conditional uses in the FW Floodway District.
(a) No structure (temporary or permanent), fill deposit (including fill for roads and levees), obstruction, storage of materials or equipment, or other use may be allowed that will cause an increase in the height of the regional flood or cause an increase in flood damages in the reach or reaches affected. The use shall not adversely affect the hydraulic capacity of the channel or floodway or any tributary to the main stream or of any ditch or other drainage facility or system. For Lake Phalen and Beaver Lake, compensating flood water storage volume shall be provided below the one hundred 100-year flood elevation for any obstruction placed in the floodplain.
(b) Fill shall be protected from erosion by vegetative cover, mulching, riprap or other acceptable method.
(c) Accessory structures shall not be designed for human habitation.
(d) Accessory structures shall be constructed and placed on the building site so as to offer the minimum obstruction to the flow of floodwaters:
(1) Whenever possible, structures shall be constructed with the longitudinal axis parallel to the direction of flood flow; and
(2) So far as practicable, structures shall be placed approximately on the same flood flow lines as those of adjoining structures.
(e) Accessory structures shall be elevated on fill or structurally dry floodproofed in accordance with the FP-1 or FP-2 floodproofing classification in the Minnesota State Building Code. As an alternative, an accessory structure may be floodproofed to the FP-3 or FP-4 floodproofing classification in the Minnesota State Building Code, provided the accessory structure constitutes a minimal investment, does not exceed five hundred (500) square feet in size, and for a detached garage, the detached garage must be used solely for parking of vehicles and limited storage. All floodproofed accessory structures must meet the following additional standards:
(1) The structure must be adequately anchored to prevent flotation, collapse or lateral movement of the structure and shall be designed to equalize hydrostatic flood forces on exterior walls;
(2) Any mechanical and utility equipment in a structure must be elevated to or above the regulatory flood protection elevation or properly floodproofed; and
(3) To allow for the equalization of hydrostatic pressure, there must be a minimum of two (2) "automatic" openings in the outside walls of the structure having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding. There must be openings on at least two (2) sides of the structure and the bottom of all openings must be no higher than one (1) foot above the lowest adjacent grade to the structure. Using human intervention to open a garage door prior to flooding will not satisfy this requirement for automatic openings.
(f) The storage or processing of materials that are, in time of flooding, flammable, explosive, or potentially injurious to human, animal, or plant life is prohibited. Storage of materials or equipment may be allowed if readily removable from the area within the time available after a flood warning and in accordance with a plan approved by the planning commission.
(g) Structural works for flood control that will change the course, current or cross-section of protected wetlands, or public waters shall be subject to the provisions of Minn. Stat., ch. 103.G. Structural works for flood control intended to remove areas from the regulatory floodplain shall not be allowed in the floodway.
(h) A levee, dike or floodwall constructed in the floodway shall not cause an increase to the regional flood and the technical analysis must assume equal conveyance or storage loss on both sides of a stream.
(i) No use shall be permitted which is likely to cause pollution of waters, as defined in Minnesota Statutes, § 115.01, unless adequate safeguards, approved by the state pollution-control agency, are provided.
(Ord. No. 25-72, § 1, 12-10-25)