236-21. Flammable and Combustible Liquids.

In addition to the regulations set forth in ch. ACTP 93, Wis. Adm. Code, above ground flammable liquid storage facilities shall comply with the following: 1. FOAM EXTINGUISHING MATERIAL. a. All new and existing above ground tanks for the storage of Class I, II or III liquids in excess of 8,000 gallons shall be provided with a supply of aqueous film, foam-producing material suitable for use in the fire department's equipment, listed in Underwriters' Laboratories or Factory Mutual, in the quantity as follows: QUANTITY OF 3% AQUEOUS ABOVE GROUND FOAM STORAGE CAPACITY SOLUTION 8,001 to 50,000 gallons 55 gallons 50,001 to 150,000 gallons 110 gallons 150,000 to 500,000 gallons 215 gallons Over 500,000 gallons 430 gallons b. The place and manner of storage of such material shall be as directed by the commissioner after obtaining approval from the fire chief, with particular consideration being given to accessibility for fire fighting purposes and susceptibility of the solution to freezing conditions. The commissioner may prorate the amount of foam-producing liquid based upon the total storage capacity in an area which has been set aside or designated for the sole purpose of the erection of storage tanks. c. Any and all material supplied for purposes of this subsection shall be compatible to the current equipment in use by the fire department. 2. RELINING OF UNDERGROUND STORAGE TANKS. The relining of steel, underground tanks used for the storage of flammable and combustible liquids shall be permitted, provided s. SPS 310.530, Wis. Adm. Code, are complied with and flex connectors are placed at the top of the tank and between the tank and the vent pipe. 3. ABOVEGROUND FLAMMABLE AND COMBUSTIBLE LIQUID STORAGE TANKS OF LESS THAN 5,000 GALLONS CAPACITY. The city of Milwaukee adopts and applies ch. ATCP 93, Wis. Adm. Code, to storage tanks otherwise excluded by s. 168.22(3), Wis. Stats. Pages 308-312 are blank.

Ask a question about Milwaukee law

Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.