For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 23-4-3(B) — Residential Uses

Code of Ordinances, City of Biloxi, Mississippi (Supp. No. 63, Update 1: codified through Ordinance No. 2607, enacted July 28, 2026) · Biloxi Land Development Ordinance § 23-4-3(B)

Corpus is an independent public-information project, not the official City of Biloxi website. Stable reference: corpuslaw.us/code/4c21b153-ccdc-465e-af34-345de570cc1d

(B) - Residential Uses

(1) Household Living a. Dwelling, Live/Work Live/work dwellings shall comply with the following standards: 1. The residential portion of the building shall occupy over 50 percent of the gross or first floor area; 2. The nonresidential portion of the building shall be located on the ground floor; 3. The nonresidential portion of the building shall comply with all applicable nonresidential building code requirements; 4. Employees shall be limited to occupants of the residential portion of the building plus up to two persons not residing in the residential portion; 5. Drive-through facilities are prohibited; 6. The use shall comply with the parking, landscaping, and open space standards for mixed uses in Article 23-6: Development Standards; and 7. Any nonresidential off-street parking shall be located as far as practicable from existing adjacent single-family dwellings. No more than three commercial vehicles associated with the nonresidential use of the dwelling shall be parked on the site or on the street in the vicinity of the site at any one time during business hours and no more than one commercial vehicle associated with the nonresidential use shall be parked overnight on the site or on the street in the vicinity of the site. 8. Signage for the nonresidential use of the building shall be limited to a single, non-illuminated sign identifying the business and not exceeding two square feet in area. b. Dwelling, Single-Family Attached or Townhouse Single-family attached or townhouse dwellings shall comply with the following standards: 1. Not more than eight dwelling units shall be included in any one single-family attached or townhouse dwelling structure. 2. For every four abutting units, single-family attached or townhouse dwelling façades and front yards shall be varied according to the following standards: A. The depth of front yards will change by a minimum of three feet. B. A variation of building materials, architectural treatment of façades, and rooflines will be applied. 3. Maintenance of common areas not individually owned by occupants shall be by a homeowners' association or similar entity. c. Dwelling, Single-Family Detached - Mississippi Cottages Mississippi cottage single-family detached dwellings shall comply with the following standards: 1. The cottage may only be utilized as owner-occupied housing units, and not authorized for use as rental properties, except that within a permitted manufactured or mobile home park, a Mississippi cottage may be utilized as a tenant-occupied housing unit upon an approved manufactured/mobile home site of record. 2. The cottage shall meet modular and International Residential Code standards. d. Dwelling, Single-Family Detached - Zero Lot Line Single-family detached dwellings in a zero lot line development shall comply with the following standards: 1. The site area is not less than one acre. 2. The minimum lot width and lot depth standards contained in 23-5: Intensity and Dimensional Standards, shall not apply. 3. A minimum ten-foot setback shall be provided between all dwelling units. 4. A five-foot maintenance easement shall be provided on and along the lot adjacent to any dwelling unit constructed on a side property line. 5. A zero-lot line unit shall be located along the designated zero-lot line, unless the dwelling unit includes an overhang which extends beyond the wall line. In that case, the dwelling unit must be set back an appropriate distance to accommodate the overhang and drainage from the roof. 6. No dwelling unit shall extend beyond the property line. (See Figure 23-4-3(B)(1)d, Zero Lot Line Example.) [image omitted; see the official code] Figure 23-4-3(B)(1)d, Zero Lot Line Example e. Dwelling, Two- to Four-Family Two-family dwellings and three- to four-family dwellings shall comply with the following standards: 1. Section 23-6-9, Multifamily Residential Design Standards. 2. Except for circular driveways, no more than one driveway shall be located on the same block face. 3. Ground based, roof-based, and wall-mounted electrical equipment, HVAC equipment and other utility connection devices shall be ganged and shall be screened or located outside the view from any adjacent public street. f. Dwelling, Upper Story Residential living above the first floor is allowed in zoning districts in which the city intends to preserve nonresidential activity at street level. Lobbies, security, and uses incidental to the residential living units may be allowed on the street level, but all principal living spaces in multi-story or multi-tenant buildings shall be above the first floor. g. Manufactured Home, Class A All class A manufactured homes shall comply with the following standards: 1. The home shall not be located on a platted lot or parcel containing another manufactured home or other principal structure except in the RMH District, where a manufactured home shall be permitted on a site in an approved manufactured or mobile home park. 2. The home shall be skirted and tied down. 3. The home shall meet wind loading capacity standards of the Building code. 4. The length of the home shall not exceed four times its width. 5. The home shall have no less than 1,200 square feet of enclosed floor area. 6. The home shall be oriented with its longer side parallel to the adjacent street, to the maximum extent practicable. 7. All wheels, axles, transporting lights, tongue, and moving hitch shall be removed before occupancy of the home. 8. The pitch of the roof of the home shall be not less than 2.2 feet of rise for each 12 feet of horizontal run. 9. The roof of the home shall be finished with a type of roofing material commonly used in site-built residential construction. 10. The exterior siding of the home shall consist predominately of wood, hardboard, vinyl, or aluminum horizontal lap siding not exceeding the reflectivity of gloss white paint, and shall be comparable in composition, appearance, and durability to the exterior siding commonly used in site-built residential construction. 11. The home shall be located on a poured foundation or on a continuously-dug and poured concrete footing around the perimeter of the home. The home shall include a continuous and permanent brick, stone, or masonry foundation or curtain wall from the frame to the ground, unpierced except for required ventilation and access. 12. All porches, decks, ramps, or entry steps shall be wood or masonry with guardrails, handrails, and pickets required by state regulations for manufactured homes. 13. All manufactured homes shall bear a valid seal indicating conformance with the 1976 National Manufactured Housing Construction and Safety Standards Act. h. Manufactured Home, Class B All class B manufactured homes shall comply with the following standards: 1. The home shall not be located on a platted lot or parcel containing another manufactured home or other principal structure except in the RMH District, where a manufactured home shall be permitted on a site in an approved manufactured or mobile home park. 2. The home shall be skirted and tied down. 3. The home shall meet wind loading capacity standards of the Building Code. i. Manufactured Home Park All manufactured home parks shall comply with the following standards: 1. Dimensional and Density Requirements A. Minimum park area: Ten acres. B. Minimum park width: 100 feet at entrance and exits and 200 feet at the portion used for manufactured home spaces. C. Minimum manufactured home space width: 40 feet. D. Minimum manufactured home space area: 3,600 square feet for each space. E. Maximum density: Ten manufactured home units for each gross acre of park. F. Maximum impervious surface coverage: 40 percent. G. Minimum setback area requirements: 1. No manufactured home, carport, or other structure shall be placed or erected closer than 15 feet to the pavement line at any internal roadway/driveway. 2. No manufactured home shall be placed or erected closer than five feet to any side or rear manufactured home space plot line; provided, however, roof projections, overhangs, rain gutters and air conditioners may project up to 18 inches into any required setback area. H. Maximum height of all structures is 25 feet. 2. Roadways A. The minimum right-of-way for internal roadways/driveways shall be 36 feet. B. The minimum pavement width for internal roadways/driveways shall be 20 feet. C. The minimum pavement width for each divided roadway shall be 16 feet, and the minimum median width shall be eight feet. D. All roadways/driveways shall be paved with a minimum of four inches of lime rock base and compacted to 100 percent of maximum density, and one inch of asphalt topping—DOT Type I, 1,800 lbs. H.F. E. All streets in a manufactured home park shall be private. 3. Drainage Each manufactured home park shall be located on a well-drained site and shall comply with the city's Administrative Manual and other applicable engineering standards for drainage. 4. Parking and Carports A. Each manufactured home site shall contain a concrete slab not less than ten by 20 feet in dimension for carport or patio. B. Each manufactured home space shall be provided with one paved off-street parking space for each manufactured home space. One additional off-street parking space shall be provided for each 200 square feet of non-storage floor area of office and laundry facilities in close proximity to it. 5. Foundation and Tie-Down Each manufactured home shall be placed on a foundation or tied down as required by the Building Code and other applicable regulatory agency requirements. 6. Utilities and Services A. Each manufactured home space shall be connected to a central water and sewer system. No individual water supply or sewage disposal system shall be permitted in any Manufactured Home Park. B. All utilities distribution and collection systems, including those for water, sewer, electricity, telephone, gas, and television cable, shall be underground. Electric power shall be serviced by individual meters. C. Each manufactured home park shall be provided with an active recreational area having a minimum area of 200 square feet for each manufactured home space. These areas shall be consolidated into usable areas with a minimum dimension of not less than 40 feet. No manufactured home space, required buffer area, street right-of-way, storage area, utility site, or utility easement shall be counted as recreational area in meeting this requirement. Recreational areas and facilities shall be owned and operated by the managers of the manufactured home park. D. Each manufactured home park shall be provided with a management office and those service buildings as are necessary to provide facilities for mail distribution; storage space for supplies, maintenance, and materials and equipment; and laundry facilities equipped with washing machines and dryers for park residents. Adequate lighting shall be provided for safe internal circulation in accordance with the same standards for Recreational Vehicle Parks (Section 23-4-3(D)(10)c., Recreational Vehicle Parks). E. Managers of a manufactured home park shall be strictly responsible for internal trash and solid waste collection. Central park collection points shall be screened from public view from without or within the park. 7. Perimeter Walls and Buffers A. Each manufactured home park shall be entirely enclosed, exclusive of driveways, at its external boundaries by a fence, evergreen hedge, or other approved landscape feature to the maximum height permitted in this Section. B. A buffer at least 25 feet wide and meeting minimum screening requirements for a Type A perimeter buffer in accordance with Section 23-6-3(E) shall be provided and maintained along streets and all property lines, and shall include suitable ground cover. (See Figure 23-4-3(B)(1)i.7.B., Example of Perimeter Buffers.) [image omitted; see the official code] Figure 23-4-3(B)(1)i.7.B: Example of Perimeter Buffers C. The DRC may require open space be set aside for manufactured home parks with 20 or more lots to be maintained for use by manufactured home park residents. 8. Street and Space Identification Manufactured home park spaces shall be numbered or otherwise adequately described and the number or other description shall be posted at the entrance and the proper space so that it can be clearly read from each street on which the space fronts or abuts. 9. Occupancy Date No space in a manufactured home park shall be occupied until at least 40 spaces are completed and ready for occupancy. j. Mobile Homes A mobile home shall be permitted only in an approved manufactured home park, existing as a lawful permitted use on the effective date of July 29, 2003. (2) Group Living a. Dormitory All dormitories shall be accessory to an educational facility located on the same site or campus, and house only persons who are students at, or employed by, the educational facility. b. Rooming or Boarding House A rooming or boarding house shall comply with the following standards: 1. No more than ten sleeping rooms shall be allowed; 2. The owner shall maintain the house as a primary residence; 3. Sleeping rooms in a rooming house shall: A. Not include individual kitchen facilities; and B. Be accessed by a common room or hallway, and shall not have individual access to the outside (except for emergency exits required by the Building Code).

Ask a question about Biloxi law

Corpus searches the Biloxi sections it holds and shows the ones that match, with their citations. Free, no sign-in.