Section 5.030. - Lot and building regulations.
A. Table of regulations. The lot and building regulations of Table 5-3 apply to all principal uses and structures in R districts, except as otherwise expressly stated in this zoning code. General exceptions to these regulations and rules for measuring compliance can be found in Chapter 90. Regulations governing accessory uses and structures can be found in Chapter 45.
Table 5-3: R District Lot and Building Regulations
Regulations | RE | RS-1 | RS-2 | RS-3 | RS-4 | RS-5 | RD | RT | RM-0 | RM-1 | RM-2 | RM-3 | RMH
Minimum Lot Area (sq. ft.)
Detached house | 22,500 | 13,500 | 9,000 | 6,900 | 5,500 | 3,300 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500
Patio house | - | - | - | 6,900 | 5,500 | 3,300 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | -
Townhouse | - | - | - | 4,500 | 4,500 | 2,200 | 2,750 | 1,600 | 1,600 | 1,600 | 1,600 | 1,600 | -
Cottage house dev't | - | - | - | - | - | 10,000 | 10,000 | 10,000 | 10,000 | 10,000 | 10,000 | 10,000 | -
Duplex | - | - | - | 6,900 | 5,500 | 3,300 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | -
Multi-unit house | - | - | - | - | - | 3,300 | 6,900 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | -
Apartment/condo | - | - | - | - | - | - | - | - | 10,000 | 10,000 | 6,000 | 24,000 | -
Mobile home park | - | - | - | - | - | - | - | - | - | - | - | - | [1]
Other allowed buildings/uses
Permitted by right | 22,500 | 13,500 | 9,000 | 6,900 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500
Special exceptions | 22,500 | 13,500 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000
Min. Lot Area per Unit (sq. ft.)
Detached house | 22,500 | 13,500 | 9,000 | 6,900 | 5,500 | 3,300 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | -
Patio house | - | - | - | 6,900 | 5,500 | 3,300 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | 5,500 | -
Townhouse | - | - | - | 4,500 | 4,500 | 2,200 | 2,750 | 1,600 | 1,600 | 1,600 | 1,600 | 1,600 | -
Cottage house dev't | - | - | - | - | - | 2,500 | 2,500 | 2,500 | 2,500 | 2,500 | 2,500 | 2,500 | -
Duplex | - | - | - | 3,450 | 2,750 | 1,650 | 2,750 | 2,750 | 2,750 | 2,750 | 2,750 | 2,750 | -
Multi-unit house | - | - | - | - | - | 1,100 | 1,800 | 1,800 | 1,800 | 1,375 | 1,100 | 900 | -
Apartment/condo | - | - | - | - | - | - | - | - | 2,900 | 1,750 | 1,100 | 400 | -
Other allowed buildings/uses
Permitted by right | - | - | - | - | - | - | - | - | 5,500 | 5,500 | 5,500 | 5,500 | 5,500
Special exceptions | 22,500 | 13,500 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000 | 12,000
Minimum Lot Width (ft.)
Detached house | 150 | 100 | 75 | 60 | 50 | 30 | 50 | 50 | 50 | 50 | 50 | 50 | -
Patio house | - | - | - | 60 | 50 | 30 | 50 | 50 | 50 | 50 | 50 | 50 | -
Townhouse | - | - | - | 30 | 25 | 20 | 25 | 20 | 20 | 20 | 20 | 20 | -
Cottage house dev't | - | - | - | - | - | 75 | 75 | 75 | 75 | 75 | 75 | 75 | -
Duplex | - | - | - | 60 | 50 | 30 | 50 | 50 | 50 | 50 | 50 | 50 | -
Multi-unit house | - | - | - | - | - | 30 | 50 | 50 | 50 | 50 | 50 | 50 | -
Apartment/condo | - | - | - | - | - | - | - | - | 100 | 100 | 50 | 100 | -
Other allowed buildings/uses
Permitted by right | 150 | 100 | 75 | 60 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50
Special exceptions | 150 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100
Minimum Street Frontage
Residential bdgs./uses [2] | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30
Min. Building Setbacks (ft.)
Street [3]
Arterial or fwy service rd. | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 10 | 10 | 10 | 10 | 35
Other streets | 35 | 35 | 30 | 25 | 20 | 20 | 25 | 10 | 10 | 10 | 10 | 10 | 25
Side (interior) [4] | 15 | 5 | 5 | 5 | 5 | 5 | 5 | 5[5] | 5[6] | 5[6] | 5[6] | 5[7] | 10
Rear [4] | 25 | 25 | 25 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 10 | 20 | 15
Min. Open Sp./Unit (sq. ft.) | 12,000 | 7,000 | 5,000 | 4,000 [8] | 2,500 | 600 | 2,000 | 1,200 | 1,200 | 600 | 200 | - | 2,500
Max. Building Height (feet) | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | - | 35
B. Table notes. The following notes refer to the bracketed numbers (e.g.," [1]") in Table 5-3:
[1] See Section 40.240 for detailed regulations governing mobile home parks.
[2] Minimum street frontage requirements apply to townhouse developments, not to individual townhouse units. Cottage house developments require minimum street frontage of 75 feet. Minimum street frontage requirements do not apply to nonresidential uses.
[3] For detached houses and duplexes on corner lots, the minimum side street setback may be reduced to 15 feet, provided that the minimum setback for street-facing garage doors is 20 feet or 20 feet from the back of the sidewalk, whichever is greater. The street setback specified in Table 5-3 applies along the other street.
Figure 5-1: Street Side Setback on Corner Lots
[image omitted; see the official code]
[4] Non-residential uses requiring special exception approval in R zoning districts, excluding Day Cares, require minimum 25-foot building setback from R-zoned lots that are vacant or occupied by residential uses. Day Cares are not subject to the required 25-foot building setback.
[5] No side setback is required for interior units in townhouse developments. Side setback applies to end units (see Figure 5-2).
Figure 5-2: Side Setbacks for Townhouses
[image omitted; see the official code]
[6] Minimum interior side setback is 10 feet for apartment/condo and permitted nonresidential buildings.
[7] Minimum interior side setback is 25 feet for apartment/condo and permitted nonresidential buildings.
[8] Minimum required open space for duplex in RS-3 is 2,500 square feet per unit.