Sec. 10-502. - Minimum requirements for applying rat stoppage.
(a) For the purpose of obtaining maximum rat stoppage at a minimum cost to the owner or occupant of business buildings or structures, the regulations prescribed in this section are set forth as minimum requirements for applying rat stoppage to all buildings or structures.
(b) The neighborhood protection official shall approve all materials used, the methods of installation, and standards of work.
(c) Solid sheet metal, expanded metal, and wire cloth specified in this section shall have a rust-resistant coating, preferably galvanized.
(d) All foundation wall ventilator openings shall be covered for their entire height and width with perforated sheet metal plates of a thickness not less than fourteen-gauge, or with expanded sheet metal of a thickness not less than eighteen-gauge, or with cast-iron grills or grates, or with any other material of sufficient strength and equal rat-resisting properties. The openings therein shall be small enough to prevent the ingress of rats, and in no instance shall be larger than one-half inch.
(e) All foundation and exterior wall openings, excluding those used for the purpose of ventilation, light, doors, and windows, such as those openings around pipes, electric cables, conduits, openings due to deteriorated walls, broken masonry, or concrete, shall be protected against the ingress of rats by closing such openings with cement mortar, concrete, or masonry, or close-fitting sheet metal or suitable size pipe flanges or other material with equal rat-resisting properties, which shall be securely fastened in place.
(f) All exposed edges of the lower eight inches of wooden doors and door jambs, serving as front, rear, or side entrances into business buildings, from the ground, basement, or cellar floors, and other doors accessible to rats, shall be protected against the gnawing of rats by covering such doors and jambs with solid sheet metal of not less than 24-gauge thickness. The same material shall be used on door sills or thresholds, or such door sills or thresholds may be constructed of cement, stone, steel, or case iron.
Doors, door jambs, and sills of coal chutes and hatchways that are constructed of wood shall be covered with solid sheet metal of 24-gauge or heavier, or they may be replaced with metal chutes of 24-gauge or heavier, installed in such manner as will prevent the ingress of rats.
All doors on which metal flashing has been applied shall be properly hinged to provide for free swinging. When closed, doors shall fit snugly so that the maximum clearance between any door, door jambs, and sill shall not be greater than three-eighths of an inch.
Door jambs and sills constructed of metal, concrete, masonry, stone, or cement mortar, or cast iron and steel, when fitting closely to exclude rats, are not required to comply with this subsection.
(g) All screen doors, regardless of where located in or on a building or structure, which are exposed to the gnawing of rats and through which a rat may gain entrance to such building or structure, shall be protected by affixing hardware cloth over the entire length and width of the screen panels of such doors and shall, in addition, be flashed with flat sheet metal strips for the entire length and width of top and bottom rails and side stiles. All door openings not having screen doors, through which rats may gain entrance to a building or structure, shall have screen doors installed, and such screen doors shall be protected from the gnawing of rats as provided for in this division and shall be equipped with adequate closing devices so that the door will at all times be properly closed.
(h) All windows and other openings for the purpose of light or ventilation located in the exterior walls, foundation, roof, or eaves accessible to rats, or which may be subject to gnawing for the purpose of gaining ingress to a building, from the ground, climbing, or by burrowing into or under buildings from the exterior or from one building or structure to another, via wires, pipes, etc., shall be protected by placing over such opening for the entire width and length of the frame, a screen made of hardware cloth 19-gauge or heavier, such screen to be inserted in a frame made of galvanized flat sheet iron of not less than 24-gauge in thickness. All such screens shall be securely riveted together and affixed as herein provided with metal screws. All such screens installed shall be portable in application. All openings accessible to rats by way of exposed pipes, wires, conduits, or structural appurtenances shall be closed and protected with guards of galvanized twenty-four-gauge flat sheet metal so as to completely block rat usage in, through or around such pipes, wires, conduits, or structural appurtenances. All guards shall be affixed in such manner as to be portable in application so as to permit necessary repairs to and not interfere with the continuity of such service, for which such pipes, wires, conduits, or structural appurtenances shall have been installed.
(i) Unless otherwise specified, all hardware cloth to be used for the purpose of rat stoppage, as referred to in this division, shall be of not less than 19-gauge wire and shall have a mesh of not greater than one-half inch. All solid flat sheet metal used for rat stoppage purposes, as referred to in this division, shall be of not less than 24-gauge in thickness and shall have a rust-resistant coating, preferably galvanized.
(j) Light wells with windows in exterior walls that are located below the outside ground level shall be protected from the ingress of rats by one of the following methods:
(1) Installing over light wells cast-iron or steel grills or steel gratings, or other material of equal strength and rat-resisting properties, with opening in grills or gratings not to exceed one-half inch in shortest dimension.
(2) Installing securely to and completely covering existing metal grills that are broken or have openings larger than one-half inch in shortest dimension, or otherwise defective, with expanded metal of 18-gauge or heavier, having openings not greater than one-half inch in shortest dimension, or with 16-gauge or heavier wire cloth with one-half inch mesh.
(3) At the option of the owner, the opening in the wall of the building below the grate may be entirely closed with brick or concrete or partially closed and the remaining open space covered with 19-gauge or heavier wire cloth with mesh not to exceed one-half inch.
(k) Business buildings constructed on piers having wooden floor sills less than 12 inches above the surface of the ground shall have the intervening space between the floor sill and the ground protected against the ingress of rats by installing a curtain wall of solid masonry or reinforced concrete of not less than four inches in thickness and 18 inches in depth below the ground surface, with a shelf or beam four inches thick extending outward from the outside of the curtain wall eight inches.
All curtain walls installed under the provisions of this division shall provide ventilator openings of not less than two square feet for each 20 lineal feet of wall, where permissible.
All curtain walls and foundation wall ventilator openings shall be covered for their entire height and width with perforated sheet metal plates of a thickness of not less than 14-gauge or with expanded sheet metal of not less than 18-gauge or with hardware cloth of not less than 18-gauge wire, such hardware cloth to be inserted in frames of 24-gauge galvanized iron, cast-iron grills or grates or with concrete with any of the aforementioned materials set firmly therein. All openings in such wire cloth, expanded metal grills, grates, or perforated sheet metal shall have openings or mesh not to exceed one-half inch in greatest width. All ventilators in curtain walls shall be portable in application. Curtain walls as installed under the provisions of this division shall extend upward from the ground level to the first floor level of the building or structure, and shall meet with outside wood siding, and there shall be installed a protective sheathing between concrete and such outside wood siding. The top of the curtain wall shall be beveled outward from the building wall to prevent water from standing and shall be affixed so as to prevent water from seeping between the curtain wall and building wall.
(Ord. No. 91-1102, § 12, 7-31-91; Ord. No. 93-514, § 26, 5-5-93; Ord. No. 93-1570, § 2(d), 12-8-93; Ord. No. 94-674, § 39, 7-6-94; Ord. No. 98-613, § 45, 8-5-98)