§ 254-38. - Means of egress.

A. Primary. Every dwelling unit shall have safe and unobstructed means of egress from every floor at ground level and above leading to safe and open space at ground level and accessible to a street. B. Secondary. In addition, there shall be a suitable and separate secondary exit from each dwelling unit by means of a doorway, stairway, protected passageway or openable window. C. Secondary from basement. The second means of egress from any basement dwelling unit may be by a second door located independently from the first means of egress and leading directly to the outside of the premises, or, in the alternative, by an openable window located no more than three (3) feet above floor level. D. From building three (3) or more stories above grade. In buildings three (3) or more stories above grade that are used as boardinghouses or lodging houses, or contain three (3) or more dwelling units or contain one (1) or more nonresidential uses and two (2) dwelling units, the secondary exit from the third story and from every additional story, if any, shall be by a metal fire escape or an enclosed stairway. E. From rooming units. Except in single-family dwellings, rooming units shall have a door opening directly into a common hallway or areaway. Any rooming unit located in the basement or at ground level shall be provided with a second means of egress that meets the same requirements as provided in Subsection C of this section. Where there is a rooming unit located above the first story, the common hallways or areaway into which it opens shall have two (2) means of egress remote from each other and one (1) of these shall open to a street of fireproof passage leading to a street and one (1) shall open to a yard or other safe space of sufficient area to accommodate all persons in the building. F. Access to exit. Access to any exit required by Subsections A through D of this section shall not necessitate passage through any other dwelling unit or part thereof nor shall any exit be subject to locking by any device which impedes or prevents ready egress. G. Door in path of egress. Any door in the path of egress shall be at least thirty (30) inches in width with a minimum height of six (6) feet six (6) inches, shall be free from obstruction and accessible from common hallways or areaways and shall open in the direction of travel if it leads to a fire escape or if it is located in a tenement house erected after 1904 or in any building erected as, or converted into, a dwelling after 1951. H. Openable window in path of egress. Where a window forms a part of egress from a dwelling unit or rooming unit or from a common areaway or hallway to a fire escape, the window opening shall be at least thirty-six (36) inches in width and thirty-four (34) inches in height, whether the window is double hung or single hung. The bottom of the opening or the sill height shall not be more than three (3) feet six (6) inches above the floor. Said window shall be easy to open and shall lead directly to the fire escape or to the immediately adjacent outside ground area with maximum drop of three (3) feet six (6) inches thereto. Screens, storm windows and other barriers to the outside shall be readily opened or removed so as not to form any obstruction to occupants seeking egress in cases of emergency. I. Location and number of exits. Where two (2) or more exits are required, each exit shall be as remote as practicable from the other exit or exits. All the exits shall be of such number and so located that the distance of travel from the door of each rooming unit or dwelling unit on each floor shall not exceed fifty (50) feet except in buildings of fireproof construction or in buildings equipped with automatic sprinkler systems throughout where the maximum distance of travel from the door of any unit to the nearest exit shall not exceed one hundred (100) feet, provided that two (2) of the exits shall be at least fifty (50) feet apart.

Ask a question about Jersey City law

Corpus searches the Jersey City sections it holds and shows the ones that match, with their citations. Free, no sign-in.