Sec. 18-176. - Adoption of the American Society of Mechanical Engineers Safety Code for Existing Elevators and Escalators; amendments.

The American Society of Mechanical Engineers Safety Code for Existing Elevators and Escalators, ASME A17.3-2015, is adopted and incorporated in this article by reference as if fully set forth, except as it is amended by the following provisions of this section. Provisions of this article are in addition to the provisions of ASME A17.3-2015. The following provisions coinciding with provisions of ASME A17.3-2015 supersede, add or delete, when indicated, the corresponding provisions of ASME A17.3-2015. The following subsection is added to the referenced model code: 1.1.2(hh) Electric freight elevators installed before 1960, and meeting the following criteria, shall be eligible to utilize the specific amendments referencing section 1.1.2 (hh) as specified in this article: (1) Speed no greater than 100 feet per minute. (2) Travel distance not greater than ten levels. (3) Inspected quarterly by a registered elevator service company. (4) Operated and ridden by employees only. (5) Constant pressure operation. 1.3.1(c) is deleted. (ASME A17.7 compliance option). 1.3.1(e) is deleted. (ASME A17.7 compliance option). The following exception is added to the referenced model code: 2.1.3 Projections in Hoistway, Exception: Freight elevators identified in section 1.1.2 (hh) are exempt from Projections in Hoistway requirements. The following exception is added to the referenced model code: 2.6.1 Doors or Gates Required, (b) Freight Elevators, Exception: Freight elevators identified in section 1.1.2 (hh) shall be permitted to have the hoistway landing guarded to a minimum height of 66 in. (1.56 m) above the landing sill. The following exception is added to the referenced model code: 3.3.5 Protection of Platforms Against Fire, Exception: Freight elevators identified in section 1.1.2 (hh) are exempted from protection of platforms against fire. The following exception is added to the referenced model code: 3.4.1 Car Enclosures, (b) Freight Elevators, Exception: Freight elevators identified in section 1.1.2 (hh) may be enclosed to a height of 66 inches, without perforations, except the portion of the enclosure in front and extending six inches on each side of the counterweights shall be without perforations and extend to the full height of the car crosshead or not less than eight feet if there is no crosshead. The following exception is added to the referenced model code: 3.4.1 Car Enclosures, (c) Car Tops, Exception: Freight elevators identified in section 1.1.2 (hh) are exempt from the structural design requirements for car tops. The following exception is added to the referenced model code: 3.5.1 Car Safeties, Exception: Freight elevators identified in section 1.1.2 (hh) employing corner suspension or having multiple guides shall be permitted to be exempt from the above requirements, provided that the elevator equipment was not originally equipped with safety devices. Existing car safety devices shall be maintained on all cars for which safeties are provided. 3.5.6 Rail Lubricants and Lubrication Plate is deleted. The following exception is added to the referenced model code: 3.6.2 Governor Ropes, Exception: Freight elevator identified in section 1.1.2 (hh) shall be permitted to have governor ropes of vegetable fiber, providing they meet the strength and size of the original vegetable fiber rope. The following exception is added to the referenced model code: 3.10.3 Top-of-Car Operating Devices, Exception: Freight elevators identified in section 1.1.2 (hh) are exempt from Top-of-Car Operating Device requirements. 3.10.10 Absorption of Regenerated Power is deleted. The following exception is added to the referenced model code: 3.11.1 Car Emergency Signaling Devices, Exception: Freight elevators identified in section 1.1.2 (hh) are exempt from Car Emergency Signaling Devices requirements. The following exception is added to the referenced model code: 3.11.1(a), Exception: Existing elevator installed prior to the adoption of this code that have maintained the following device: A weatherproof audible signaling device with a minimum sound rating of 80 dBA operated from the alarm switch and emergency stop switch inside the car and identified "ELEVATOR EMERGENCY-CALL POLICE", in letters not less than two inches (51 mm) high. The device shall be mounted on the outside of the building near the main entrance and located so that the sign can be read from the entrance sidewalk. Only one outside signal is required if operable from all cars of all elevators of the type specified in the building. The following subsection found in the referenced model code is amended as follows: 3.11.3 Firefighters service Elevators with firefighters' service that are part of a group shall conform to identical firefighters' service operation requirements regardless of which edition of A17.1 they complied with at the time of installation or alteration. The Phase I and Phase II switches for all elevators in a building or site shall be operable by the same key. 4.5.1 (b) Minimal Liquid Level Indicator is deleted. 4.5.2 (d) Inspector's Gage Connection is deleted. 4.5.2 (f) Handholes and Manholes is deleted. PART VI DUMBWAITERS is deleted. PART VII HAND ELEVATORS is deleted. PART VIII SIDEWALK ELEVATORS is deleted.

(Ord. No. 200418, § 1, 6-18-20)