§ 6-151 — Amendments to residential code
Code of Ordinances of the City of Tyler, Texas (September 2026: including amendments through September 9, 2026) · Tyler City Code § 6-151
Corpus is an independent public-information project, not the official City of Tyler website. Stable reference: corpuslaw.us/code/4ea582a7-67da-4384-9e76-4dac7e0c4581
Section 6-151. Amendments to residential code.
The 2021 International Residential Code, as adopted in Section 6-150, is hereby amended as follows: a. Section R102.7 is amended to read as follows: R102.7. Existing structures. The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change, except as is specifically covered in this code, the International Fire Code, or any other code, or as is deemed necessary by the building official for the general safety and welfare of the occupants and the public. (Ord. No. O-2013-27; 3/27/13) (Ord. No. O-2018-14; 1/24/18) b. Section R103.1 is amended to read as follows: R103.1. Enforcement agency. The Building Services Department is the enforcement agency. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code. c. Section R103.2 is amended to read as follows: R103.2. Appointment. The Chief Building Official or designee is hereby appointed as the building official for purposes of this code. d. Section R104.8.1 is amended by adding a sentence at the end to read as follows: Indemnification of City officials, City employees, and members of City Council appointed boards is governed by City Code Section 2-62. (Ord. No. 0-2013-27; 3/27/13) (Ord. No. O-2018-14; 1/24/18) (Ord. No. O-2023-104; 10/25/23) e. Section R112 is deleted in its entirety and a new Section R112 is adopted as follows: R112. Construction Board of Adjustment and Appeals R112.1. Appointment. There is hereby established a board to be called the Construction Board of Adjustment and Appeals, which shall consist of seven members. The Board shall be appointed by the applicable governing body. R112.2. Membership and Terms. R112.2.1. Membership. Such board members should be composed of individuals with knowledge and experience in the technical codes, such as design professionals, contractors or building industry representatives. At least one member shall have either a Master Electrician's license or be a licensed electrical engineer, but if this requirement cannot be met, the membership requirement may also be met by Board members in other businesses or professions. A majority of the Board shall be City of Tyler residents, while a minority may reside in the City's extraterritorial jurisdiction. A board member shall not act in a case in which the member has a personal or financial interest. Terms shall be as set forth in City Code Section 1-20. R112.2.2. Quorum and Voting. A simple majority of the board shall constitute a quorum. In varying any provision of this code, the affirmative votes of the majority present, but not less than three affirmative votes, shall be required. In modifying a decision of the building official, not less than four affirmative votes, but not less than a majority of the board, shall be required. R112.2.3. Secretary of Board. The Building official shall act as secretary of the board and shall make a detailed record of all of its proceedings, which shall set forth the reasons for its decision, the vote of each member, and the absence of a member and any failure of a member to vote. R112.3. Powers. The Construction Board of Adjustment and Appeals shall have the power, as further defined in 112.4, to hear appeals of decisions and interpretations of the Building official and consider variances of the technical codes. R112.4. Appeals R112.4.1. Decision of the Building Official. The owner of a building, structure or service system, or duly authorized agent, may appeal a decision of the Building official to the Construction Board of Adjustment and Appeals whenever any one of the following conditions is claimed to exist: 1. The Building official rejected or refused to approve the mode or manner of construction proposed to be followed or materials to be used in the installation or alteration of a building, structure or service system. 2. The provisions of this code do not apply to this specific case. 3. That an equally good or more desirable form of installation can be employed in any specific case. 4. The true intent and meaning of this code or any of the regulations there under have been misconstrued or incorrectly interpreted. R112.4.2.Variances. The Construction Board of Adjustment and Appeals, when so appealed to and after a hearing, may vary the application of any provision of this code to any particular case when, in its opinion, the enforcement thereof would do manifest injustice and would be contrary to the spirit and purpose of this or the technical codes or public interest, and also finds all of the following: 1. That special conditions and circumstances exist which are peculiar to the building, structure or service system involved and which are not applicable to others. 2. That the special conditions and circumstances do not result from the action or inaction of the applicant. 3. That granting the variance requested will not confer on the applicant any special privilege that is denied by this code to other buildings, structures or service system. 4. That the variance granted is the minimum variance that will make possible the reasonable use of the building, structure or service system. 5. That the grant of the variance will be in harmony with the general intent and purpose of this code and will not be detrimental to the public health, safety and welfare. R112.4.2.1. Conditions of the Variance. In granting the variance, the board may prescribe a reasonable time limit within which the action for which the variance is required shall be commenced or completed or both. In addition, the board may prescribe appropriate conditions and safeguards in conformity with this code. Violation of the conditions of a variance shall be deemed a violation of this code. R112.4.3. Notice of Appeal. Notice of appeal shall be in writing and filed within 30 calendar days after the decision is rendered by the Building official. Appeals shall be in a form acceptable to the Building official. R112.4.4. Unsafe or Dangerous Buildings or Service Systems. In the case of a building, structure or service system which, in the opinion of the Building official, is unsafe, unsanitary or dangerous, the Building official may, in the order, limit the time for such appeals to a shorter period. R112.5. Procedures of the Board. R112.5.1. Rules and Regulations. The board shall establish rules and regulations for its own procedure not inconsistent with City rules and ordinances, and the provisions of this code. The board shall meet on call of the chairperson. The board shall meet within 30 calendar days after notice of appeal has been received. R112.5.2. Decisions. The Construction Board of Adjustment and Appeals shall, in every case, reach a decision without unreasonable or unnecessary delay. Each decision of the board shall also include the reasons for the decision. If a decision of the board reverses or modifies a refusal, order, or disallowance of the building official or varies the application of any provision of this code, the building official shall immediately take action in accordance with such decision. Every decision shall be promptly filed in writing in the office of the building official and shall be open to public inspection. A copy of the decision shall be sent by mail or otherwise to the appellant. Every decision of the board shall be final, subject however to such remedy as any aggrieved party might have at law or in equity. (Ord. No. O-2013-27; 3/27/13) (Ord. No. O-2018-14; 1/24/18) (Ord. No. O-2023-104; 10/25/23) f. Section R113.4 is amended by adding a sentence at the end to read as follows: Penalties for violations of this code are set forth in City Code Section 1-4. g. Section 302.5.1 is amended by adding an exception, to read as follows: Doors shall not be self-latching and equipped with a self-closing or automatic-closing device. Exception. A combination smoke/CO-detector may be installed within 3' of the door opening, per the manufacturer's specifications, in lieu of the above requirement that doors shall self-latching and equipped with a self-closing or automatic-closing device. (Ord. No. 0-2013-27; 3/27/13) (Ord. No. O-2018-14; 1/24/18) (Ord. No. O-2023-104; 10/25/23) h. Section 315.2.1 is amended to read as follows: R315.2.1. Carbon monoxide alarms. For new construction, an approved carbon monoxide alarm shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages; or in dwelling units within which fuel-fired appliances are installed that do not have attached garages; or in dwelling units that have attached garages. (Ord. No. O-2013-27; 3/27/13) (Ord. No. O-2018-14; 1/24/18) (Ord. No. O-2023-104; 10/25/23) j. Section 320 is deleted in its entirety. k. Figure R403.3 (1) is deleted in its entirety. l. Section R506.2.3 is amended by amending the first sentence to read as follows, and keeping the existing Exceptions: R506.2.3. A minimum 6-mil vapor retarder conforming to ASTM E1745 Class A requirements shall be placed between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist. m. Section M1305.1.3 is amended by amending the first sentence to read as follows: Attics containing appliances requiring access shall be provided with an opening and a clear and unobstructed passageway large enough to allow removal of the largest appliance, but not less than thirty-six inches high and 22 inches wide and not more than twenty feet (20') in length when measured along the centerline of the passageway from the opening to the appliance. n. Add a new Section M1305.1.3.2 as follows: M1305.1.3.2. HVAC systems accessed with a pull-down stairway. When a HVAC system covered by this Code is accessed with a pull-down stairway, such pull-down stairway shall be rated for 250-pound capacity. o. Add a new Section M1305.1.3.3. as follows: M1305.1.3.3.Access panels in ceiling. Where the access panel is installed in a ceiling, flooring shall extend thirty inches (30") on three (3) sides of the opening. The flooring shall be sized per Table R503.1 of the 2006 International Residential Code. p. Delete current Section M1404, "Compliance" in its entirety, and replace with Section M1404 of the 2024 International Residential Code as promulgated by the International Code Council (ICC). (Ord. No. O-2025-25;5/28/25) q. Delete current Section M1411, "Heating and Cooling Requirements", in its entirety, and replace with Section M1411, "Heating and Cooling Requirements" of the 2024 International Residential Code as promulgated by the International Code Council (ICC). (Ord. No. O-2025-25;5/28/25) r. Delete current Section M1412., "Approval of Equipment", in its entirety, and replace with Section M1412, "Listed Equipment", of the 2024 International Residential Code as promulgated by the International Code Council (ICC). (Ord. No. O-2025-25;5/28/25) s. Delete current Section M2006.1, "General" with Exception, in their entireties, and replace with Section M2006.1, "General" with Exception, of the 2024 International Residential Code as promulgated by the International Code Council (ICC). (Ord. No. O-2025-25;5/28/25) Re-number current Subsection p. as New Subsection t., with no other changes. u. Delete current Section ASHRAE-34-2019, "Designation and Safety Classification of Refrigerants" in its entirety, and replace with ASHRAE 34-2022 (M14111) (2024 IRC) of the 2024 International Residential Code as promulgated by the International Code Council (ICC). (Ord. No. O-2025-25;5/28/25) v. Delete current Section UL/CSA/ANCE 60335-2040-2012: "Standard for Household and Similar Electrical Appliances, Part 2: Particular Requirements for Motor-compressors" in its entirety, and replace with UL/CSA 60335-2-40-20022 2024) IRC, "Household and similar electrical appliances-Part 2-20,: Particular requirements for electric heat pumps, air conditioners and dehumidifiers" (M1402, M1403.1, M1412.1, M1413.1, M2006.1), as promulgated by the 2024 International Residential Code Council (ICC). (Ord. No. O-2025-25;5/28/25) Current Subsections q. through r. are hereby re-numbered as New Subsections w. through x., with no other changes. (Ord. No. O-2007-11; 1/24/07) (Ord. No. O-2013-27; 3/27/13) (Ord. No. O-2016-17; 2/24/16) (Ord. No. O-2018-14; 1/24/18) (Ord. No. O-2019-72; 8/28/19) (Ord. No. 0-2021-24; 3/24/21) (Ord. No. O-2023-104; 10/25/23) (Ord. No. O-2025-25;5/28/25)
Ask a question about Tyler law
Corpus searches the Tyler sections it holds and shows the ones that match, with their citations. Free, no sign-in.
