17.50.250 - Residential Uses - Accessory Uses and Structures
A. Limitation on use. Accessory structures shall be limited to uses which are accessory to the main use, including but not limited to, cabana, garage or carport, gazebo, greenhouse, pergola, pool, or hot tub and related equipment, or workshop. An accessory structure shall not be used for sleeping quarters. B. Restricted items and facilities. 1. Prohibited facilities. Bathtubs, fireplaces, and kitchens (full or partial) are prohibited within accessory structures. 2. Allowed, but restricted facilities. Air conditioning, heating, shower, toilet, washtub, and/or washer and dryer facilities are allowed within accessory structures; however: a. When an accessory structure contains air conditioning, heating, shower, and/or toilet facilities, a covenant shall be required. b. The covenant shall state that the structure is an accessory structure and shall be maintained as an accessory structure and not be used for sleeping quarters or be converted to a residential use. c. The purpose of this covenant is to ensure that subsequent owners of the property are aware of the restrictions on the property. 3. Attic area and stairs. The area above the ceiling joists may only be used as a storage area. This storage area shall be accessed only by a pull down stairs. 4. Rooftop decks. Rooftop decks are prohibited. 5. Other related items. Other related items not listed above may only be allowed if first approved by the Zoning Administrator. C. Timing of construction. An accessory structure shall not be constructed before the main structure. D. Limitation on location. 1. An accessory structure shall not occupy a required front or corner side setback. 2. An accessory structure may be located in a required side or rear setback; provided it is more than 100 feet from the front property line or in the rear 25 feet of the site. 3. A lot abutting on the front 100 feet of a key lot shall maintain a minimum four-foot rear setback. E. Size, height, and setback requirements. 1. Height limits. a. Nine-foot limit with two-foot setback. An accessory structure shall not exceed a height of nine feet, but only if located two feet from a property line. b. Nine-foot top plate. The height of the top plate of an accessory structure shall not exceed nine feet. c. Encroachment plane and setback. The overall height of an accessory structure (excluding the top plate height) may rise above the nine-foot height limit as it steps or slopes away from the two-foot initial setback, but shall not intercept an encroachment plane sloping inward from a point nine feet in height (beginning at the two-foot setback) and rising a maximum of one and one-half feet for each one foot of distance starting at the two-foot setback. See Figure 5-1. [image omitted; see the official code] Figure 5-1 Encroachment Plane and Setbacks for Accessory Structures d. 15-foot limit. An accessory structure may raise to, but shall not exceed, an overall height of 15 feet, but only in compliance with Subparagraph c., immediately above. e. Roof Pitch. Proposed accessory structures shall maintain a roof pitch equal to or within 1/12 of the predominant roof pitch of the existing primary dwelling. This requirement is not applicable to properties within an historic district, LD, HD, HD-1, or ND overlay zone. f. Materials. When visible from a public right-of-way, the exterior finish, trim, and roof materials shall be demonstrably similar to the finish, trim, and roof materials found on the primary structure or to materials found within properties along the blockface. This requirement is not applicable to properties within an historic district, LD, HD, HD-1, or ND overlay zone. g. Modification by Minor Conditional Use Permit. In order to achieve a design that is architecturally compatible with the main structure, the maximum height (including the top plate height) may be modified by a Minor Conditional Use Permit, granted in compliance with Section 17.61.050. h. Modification by Historic Preservation Commission. Modification for historic resources. For designated landmarks or structures in a designated landmark or historic district, the maximum height (including the top plate height) of an accessory structure may be exceeded without a Minor Conditional Use Permit, but only if approved by the Director, and only upon finding that the greater height is necessary in order to achieve a design that is architecturally compatible with the main structure. 2. Length of structure walls. a. In order to prevent an excessive amount of structure located along a property line, the maximum horizontal length of an accessory structure that can be located less than five feet from the property line shall be limited to 22 feet. b. Any portion of the structure that exceeds 22 feet in length and is less than five feet from the property line, shall be required to be set back a minimum of five feet from the property line. F. Separations between structures. 1. Utility pole. When a utility pole is located on the same site as a proposed accessory structure, a minimum separation of at least four feet shall be maintained between the pole and the accessory structure. 2. Other structures. An accessory structure, other than mechanical equipment, a hot tub, or a swimming pool, shall maintain a minimum separation of six feet from any other structure (excluding walls and fences) on the site. The separation shall be clear and unobstructed by any encroachments. 3. Pools and hot tubs. Pools, hot tubs, and related equipment, and all mechanical equipment shall not be closer than five feet from a property line. The Zoning Administrator may modify this requirement for pool equipment when adjacent to an alley. G. Maximum floor area of accessory structures. 1. Maximum Size. a. Projects using the RS standards. The maximum size of all accessory structures on a site shall no exceed an aggregate of 600 square feet or six percent of the lot size, whichever is greater. b. Projects using the RM-12 standards. The maximum size of all accessory structures on a site shall not exceed an aggregate of 600 square feet or six percent of the lot size, whichever is greater. However, an additional 200 square feet is permitted if used for covered parking. c. Projects using other multi-family standards. The maximum size of all accessory structures on a site shall not exceed an aggregate of 600 square feet or six percent of the lot size, whichever is greater. 2. An accessory structure (or portion of an accessory structure) with a roof that is at least 50 percent open shall not be included in the calculation of the maximum allowable size. All other accessory structures shall be counted in the calculation of the maximum allowable size including carports, gazebos, or covered patio or porches. A basement below an accessory structure or a stand alone subterranean structure shall be included in the calculation of the maximum allowable size. H. Garages and carports. 1. Attached garages. On a lot 50 feet in width or wider, an attached garage that is visible from the street shall not occupy more than 50 percent of the structure frontage of the main structure. 2. Carports. A carport shall only be located behind the main structure and not visible from a public right-of-way, and shall not be allowed on a corner lot.
(Ord. No. 7435, § 18, 10-28-2024; Ord. 7372, § 10, 2021; Ord. 7371 § 5, 2021; Ord. 7160, § 48, 2009; Ord. 7099, § 34 (Exh. 23), 2007; Ord. 7057, § 18 (a, b), 2006; Ord. 7009, § 22, 2005)
Ask a question about Pasadena law
Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.