Sec. 49-1524. - Water service.
A water service line is the pipe and related appurtenances installed from the water purveyor's water main to the outlet connection of the first shut-off device downstream of the meter or meters or the first shut-off device inside of the building, whichever is farther downstream. On services where a bypass around the meter is required, the bypass is considered part of the service. When the service is used for fire protection, the service is from the main to the outlet of the backflow preventers. (a) All residential service lines shall be properly sized for the required demand, but shall be at least one inch inside diameter. Exception: Repair of an existing three-fourth inch service will be allowed. (b) Commercial, industrial and fire service lines shall be properly sized for the required demand, but shall be no smaller than as specified for a residential service in Table 49-1521(b). (c) All water services three-quarters inch through 1¼ inches shall be type K copper (except that portion of the service from the first valve inside the building to the first valve downstream of the meter which shall be Type K, L, or M copper tubing). (d) All water services 1½-inches and larger shall be Class 52 or heavier ductile iron water main, red brass or Type K copper. (e) All joints on copper water services larger than one inch shall be hard solder (brazed) or flared. (f) Water services for new or remodeled buildings shall be sized to meet the water fixture unit requirements. (g) All water services shall meet any other requirements of the Metropolitan Utilities District (MUD). (h) A private fire service main, or a combination domestic water service line and fire service line (along with their appurtenances), shall be installed according to water purveyor's water rules and regulations, ANSI/AWWA Standard C600-87, NFPA 24, and as required elsewhere in this chapter. When more than 50 percent of a fire service main is replaced, the service shall meet current code. (i) In addition to the valve required at the main, additional valves must be installed on each of the service branches, including the private fire service and hydrants so that each line may be controlled independently.
(Ord. No. 40524, § 1, 10-20-15)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.