Sec. 74.89. - Restoration and rehabilitation.
(a) Exterior surfaces—Walls and foundations: Masonry. In the 1860s and 1870s, a number of Saint Paul businessmen built elaborate limestone houses along the bluff. These houses are long gone, but several brick houses remain, and brick and stone are evident throughout the historic district in foundations and chimneys. Stone, brick and concrete were also used for lintels, sills and decorative trim. Improperly maintained or repair masonry can result in extensive water damage and eventual structural failure.
(1) Repair. Deteriorated brick, stone, mortar and other materials should be replaced with material used in the original construction or with materials that resemble the appearance of the original as closely as possible. The advice of a skilled mason should be sought for major repair projects.
(2) Cleaning. Masonry cleaning should be conducted only to halt deterioration and by means such as low-pressure water, soft brushes, and/or appropriate chemical treatment. Sandblasting or abrasive cleaning should not be used under any circumstances.
(3) Repointing. Original mortar joint size and profile should be retained and/or reduplicated in repointing. Mortar mixtures should duplicate the original in lime, sand and cement proportion and should duplicate the original mortar in color and texture.
(4) Stucco resurfacing. Repairs to stucco surfaces should duplicate the original in color and texture, if evidence exists. Smooth or heavy dashed surfaces should be avoided unless they were used on the original surface.
(5) Painting. The original color and texture of masonry surfaces should be retained and unpainted stone and brick surfaces should not be painted. The removal of paint from painted masonry surfaces should only be attempted if unpainted surfaces are historically appropriate and if removal can be accomplished without damage to the masonry.
(6) Resurfacing. Stucco, artificial stone, brick veneer, or vinyl or aluminum products should not be applied over masonry surfaces.
(See also Chimney Guidelines; Retaining Wall Guidelines)
(b) Exterior surfaces—Walls: Wood sided. Wood building products, including siding, shingles and a great variety of decorative trim were used extensively by the nineteenth- and early twentieth-century builders of Dayton's Bluff. Wood contributes texture and detail to the historic district and is a durable, high-quality material with a long product life if properly maintained.
(1) Repair. Wooden siding should be maintained with paint or stain. Deteriorated wooden siding should be replaced with new material resembling the original in width, thickness and profile, and texture. New siding should be installed with the weather (exposed surface) identical to the original. Siding should be installed horizontally except in those instances where vertical or diagonal siding was used on the original exterior. Appropriate corner boards, frieze boards, drip caps and other features should be included with replacement siding.
(2) Vinyl and aluminum siding; other manufacture products. Buildings originally clad in wooden siding should not be resurfaced with brick, stucco, artificial stone or brick veneer, hardboard, or vinyl or aluminum siding. The commission may consider the following exceptions to the installation of vinyl, metal or hardboard siding on a case-by-case basis:
a. In cases where existing asphalt, asbestos, aluminum or vinyl siding is to be removed and where the underlying original siding and decorative features are found to be significantly deteriorated. Commission staff must conduct a site visit during the removal process and advise on appropriate treatment.
b. In the resurfacing of noncontributing building constructed after 1930.
c. In the resurfacing or existing or construction of new garages, particularly when the garage is inconspicuously sited.
If vinyl, metal or hardboard siding is used as described in A-C, it must be of a width appropriate to the style of the building, and all architectural details including window trim, wood cornices and ornament must remain uncovered. Replacement siding may cover only one layer of existing siding. Trim must be built up so that it projects from the new siding to the same extent as the original.
(3) Shingles. Buildings originally clad in horizontal wooden siding should not be resurfaced with shingles of wood or other material. Wooden shingles used for cladding material or decoration, such as in the gable ends, should be conserved and retained. If replacement is necessary, shingles should replicate the original in width, pattern, thickness, profile, texture and weather (lap).
(4) Decorative siding treatments. Decorative siding treatments, such as paneled herringbone patterns used in the gable ends, should be retained in repair or resurfacing.
(5) Painting. Exterior wooden surfaces should be maintained with appropriate paint or stain. Color choice is not subject to heritage preservation commission approval. However, exterior paint colors should be appropriate to the period and style of the historic building. Stained shingles in most cases should not be painted.
(c) Roofs and chimneys. The shape, texture and color of the roof are important design features of any building. Gable and hipped roofs are most common in the historic district. Many of the early building of Dayton's Bluff were roofed in cedar shingles and reroofed with asphalt shingles. Properly selected, modern asphalt roofing materials are compatible with the appearance of historic buildings.
(1) Roofing materials. Original roofing materials which contribute to the character of the district such as tile and slate should be maintained and retained unless badly deteriorated. If partial reroofing in tile, slate or asphalt is necessary, replacement roofing should match the old in composition, size, shape and texture. New roofing material should be appropriate to the character of the building in composition, size, shape and texture. Dark brown, dark gray and "weathered wood" are among usually acceptable colors. Rolled roofing may be used only on flat or slightly sloped roofs which are not visible from the public way.
(2) Alterations to roof shape—Front. The original roof type, slope and overhangs should not be preserved. The roof shape at the front should not be altered except to restore it to the original documented appearance or to add architecturally compatible dormers. Documentation includes evidence of the former appearance of the building, or, in the case of pattern book houses, those of similar period and style. The shape of existing dormers should not be altered unless compatible with the original design.
(3) Alterations to roof shape—Rear. Alterations to the roof shape at the sides or rear should be compatible with the architectural character of the building.
(4) Skylights. Skylights should not be installed on the front roof plane. They should be flat and as close to the roof plane as possible. "Bubble"-type skylights should not be installed.
(5) Rebuilt chimneys. If rebuilding is necessary, original brick details such as decorative panels and coffers should be replicated. In the absence of evidence of the original appearance of the chimney, repair or rebuilding should be compatible with the building style or type.
(6) Chimneys and stovepipes. New chimneys and stovepipes should not be installed on the front roof plane.
(See also: New Addition Guidelines)
(d) Windows and entries:
(1) Windows: Many of the historic windows of Dayton's Bluff have double-hung sash and vertical orientation. Windows are important design elements and establish the visual rhythm, balance and general character of the façade. Any alteration, including removal of moldings or changes in window size or type, can have a significant and often detrimental effect on the appearance of the building as well as on the surrounding streetscape.
a. Size and shape. Existing window openings should be retained. Window openings should not be enlarged or reduced to fit new units. New window openings should not be introduced into principal elevations.
b. Sash. The size and number of panes of glass in each sash should not be altered. New sash, if installed, should duplicate the existing or other appropriate historic models. Crank-out or sliding units are not appropriate replacement for double-hung sash.
c. Trim. Historic window casings should be retained wherever possible; if replacement is necessary, the original profile should be replicated.
d. Storm windows. If combination metal storms are installed, they should have a baked-enamel finish. Storm windows should not have vertical or horizontal divisions which conflict with the divisions of the sash.
e. Shutters and blinds. Shutters and blinds should not be installed on buildings not originally designed for them. Where appropriate, shutters should appear to be operative and should be mounted to the window casing. Shutters should be constructed of wood.
f. Security measures. Historic trim or other architectural features should not be removed for the installation of security bars or grills.
(2) Entries: The entry—including the door, door surround and sometimes sidelights and a transom—is usually the focal point of the façade. The size of the entry is directly related to the mass and scale of the building. As with windows, any alteration to size, shape or trim details can have a detrimental effect on exterior appearance.
a. Size and shape. All historic entry components should be retained. Entry opening should not be enlarged or reduced to fit a new door. New entry openings should not be introduced into principal elevations.
b. Trim. Original or historic features of the entry, including hoods, columns, sidelights and transoms, should be retained. If replacement is necessary, historic trim details should be replicated.
c. Doors. Wherever possible, historic paneled doors (and hardware) should be repaired and weatherstripped rather than replaced. If replacement of original or historic doors is necessary, the replacement should duplicate or be compatible with the material, design and hardware of the older door. Steel-covered hollow core doors should not be installed unless compatible with the appearance of the house. Historic trim should not be removed from the entry for the installation of steel doors.
d. Storm and screen doors. Storm doors should be compatible with the inner door in shape and style. Simple designs are preferable to "ranch style" designs.
e. Sliding glass doors. Sliding glass doors should be confined to the rear of the building where not visible from the public way.
f. Security measures. Historic trim or other architectural features should not be removed for the installation of security bars or grills.
(e) Porches and steps. Most of the houses and rowhouses built in the Dayton's Bluff Historic District before 1920 had unenclosed front porches. The porch usually stretched across the full width of the front façade, but in some cases only covered the entry. Since porches and steps are exposed to the weather and receive hard use, some buildings have had a succession of replacements which reflect different styles of architecture.
(1) Conservation. Porches, steps and handrails which are appropriate to the building and its development should be conserved and retained.
(2) Repair and replacement. Historic porches, steps or handrails which require complete rebuilding or partial replacement should be reconstructed using historical research to determine an appropriate design. Reconstructions should be compatible with the period and style of the building in material, design and detail. Concrete should not be used to replace wooden porch floors or steps.
(3) Railings. The original spacing, section and profile of balusters should be maintained in replacement or repair. Unless historical evidence indicates, reconstruction should include a bottom rail and balusters should not be nailed directly to the step or deck. Wooden posts and railings should not be replaced with those of metal.
(4) Posts and columns. If replacement is necessary, porch posts and columns should be replaced with units which replicate the original material, size and scale. Elaborate details such as turning, gouging or stamping may be simplified if necessary. Wooden posts or railings should not be replaced with metal posts or railings.
(5) Enclosure. Unenclosed front porches should not be permanently enclosed.
(6) Decks. Decks should be constructed only at the rear of the building or where most inconspicuous. Railings, steps and other deck details should be compatible with the architectural character of the building.
(7) Firestairs. The detailing of firestairs should be compatible with the period and style of the building. Firestairs should be located as inconspicuously as possible.
(f) Exterior trim and architectural features. Exterior trim includes the decorative and sometimes functional elements of the exterior which contribute to the proportion, texture and detail of the building. A great variety of machine-made trim was added to even the simplest wooden houses of Dayton's Bluff, while iron, cast iron, terra cotta, tile and brick can be seen on masonry examples.
(1) Conservation. Exterior architectural features including finials, cornices, brackets, columns, balustrades and railing, and window and door moldings should be retained.
(2) Documentation. Original trim details and other architectural features should be photographed or otherwise recorded before they are removed for repair or replacement. Deteriorated trim which is removed should be saved for use in making duplicates.
(3) Repair and replacement. New material used to repair or replace deteriorated trim or other features should match the original as closely as possible. Deteriorated trim which is unsalvageable should be replaced with trim identical or similar to the original design. Simplified trim should approximate the old in design and placement.
(4) New trim. Details should not be added in an effort to make the building look older. However, in the case of some "pattern book" houses, the addition of certain trim details such as those typical at the gable and porch may be permitted if supported by historic photos or pattern book sources.
(g) Storefronts; rehabilitation and restoration. The commercial buildings within the district are of masonry construction and date from the 1880s through 1920s. Each building has a special style or character that belongs to its period of construction. Although each building is unique, most share a two-part horizontal division with glazed (or once-glazed) storefronts at the first story. The storefronts—the façades of individual shops—usually support a band of uniformly sized windows and decorative cornice above.
(1) Conservation. The original appearance of commercial buildings and storefronts should be conserved. Decorative features such as columns or brackets should be retained in repair and renovation projects. Storefronts should not obscure the basic architectural framework of the buildings which they occupy. Storefront design should not reproduce styles of a period earlier than the building they occupy.
(2) Masonry surfaces. Masonry and other original surfaces should be conserved. Brick should not be covered with stucco, shakes, or other veneer. Unpainted masonry surfaces should not be painted.
(3) Windows. Windows should not be filled in with wood, brick or any other material. Window sizes and shapes should be maintained if removal of original units is necessary.
(4) Roofs and parapets. The original roofline—including cornice, parapet and other elements—should be maintained.
(5) Signs. Signs should be compatible with the character of the building and surrounding area. Signs should be appropriately sized and complement the building exterior; roof-top signs are inappropriate. They should not conceal architectural details or features. Sign materials should be compatible with the materials of the building to which they are attached. No part of the historic façade should be damaged in the installation of the sign.
(6) Awnings. Awnings should be sized to fit the windows and storefront(s) behind them. Awning materials and details should be compatible with the architectural character of the building. No part of the historic façade should be irreversibly damaged or altered during the installation of the awning.
(C.F. 92-900, § 2(I)(A), 7-23-92)