Sec. 25-81. - Riverfront district.
a. Purpose. The riverfront of the Black Warrior River is a unique natural, scenic, and historic resource of the city. The purpose of the riverfront (R) district is to, as appropriate, provide lands that support pedestrian-friendly, high-quality development that takes advantage of the Black Warrior River's history and scenic beauty, protect against flooding, and preserves the natural features of the river and its floodplain. The district should include only nonresidential uses, or residential uses mixed with complimentary nonresidential uses. Streets, buildings, and open space should create synergy with the natural riverfront environment, preserving and/or enhancing environmentally sensitive areas while allowing people within and around the district to maintain a visual or actual connection with the riverfront through the riverwalk.
b. Procedure. Development or redevelopment in the R district shall be subject to approval in one of two (2) ways.
1. Small-scale development.
i. Small-scale development shall be treated as allowed development in the R district and is subject to all the applicable standards, procedures, and requirements of the district, this zoning ordinance, and the subdivision regulations, except for redevelopment identified in subsection 3. below, which is exempt from certain development standards.
ii. For the purpose of the R district, except for certain redevelopment identified in subsection 3. below, small-scale development is proposed development that results in twenty thousand (20,000) square feet or less of nonresidential development, and/or twenty (20) residential units, or development that is located on a lot that is twenty-five thousand (25,000) square feet or less.
2. Large-scale development.
i. Large-scale development shall be classified as a riverfront planned development (RPD) district, in accordance with the procedures and standards of section 25-37, planned development, section 25-91, general provisions, and section 25-93, riverfront planned development.
ii. For the purpose of the R district, large-scale development is all proposed development in the district that is not small-scale development.
3. Exemptions. The expansion or alteration of development existing prior to January 1, 2025 that increases the building's floor area by less than fifty (50) per cent or involves alterations that involve less than fifty (50) per cent of the building's gross floor area, shall also be considered small-scale development, but shall only be required to comply with the following development standards to the extent listed below:
i. Subsection e.1., site design standards.
(a) Subsection e.1.i., view of river preserved (comply);
(b) Subsection e.1.ii., supplemental zone adjacent to riverwalk (comply to the maximum extent practicable);
(c) Subsection e.1.iv., pedestrian circulation system (comply to the maximum extent practicable);
(d) Subsection e.1.v., parking (comply to the maximum extent practicable);
(e) Subsection e.1.vii., exterior lighting (comply);
(f) Subsection e.1.viii., signs (comply to the maximum extent practicable); and
(g) Subsection e.1.ix., utilities (comply to the maximum extent practicable).
ii. Subsection e.2., building design
(a) Subsection e.2.iv., fenestration/transparency (comply to the maximum extent practicable); and
(b) Subsection e.2.vi., loading, service, and equipment areas (comply to the maximum extent practicable).
c. Use standards.
1. Small-scale development. Allowed uses and use-specific standards for principal, accessory, and temporary uses for small-scale development are the allowed uses for the R district that are established in article V, use regulations.
2. Large-scale development. Allowed uses and use-specific standards for principal, accessory, and temporary uses for large-scale development are those uses identified in article V, use regulations, as uses that may be allowed in the RPD district. However, only those uses identified as permitted in the approved PD plan are permitted in an individual RPD district, subject to the conditions and requirements in the approved PD plan and PD agreement, (see c, classification of land to a planned development district).
3. Use-specific standards. The following use specific standards apply to both small-scale development and large-scale development, in addition to any additional applicable standards for specific uses in article V, use regulations.
i. Multifamily.
(a) Multifamily dwellings are allowed only if thirty-five (35) per cent or more of the total floor area of all buildings in the proposed development is used for commercial uses. (Townhomes are not subject to this requirement).
(b) The maximum residential density for multifamily and townhomes is sixty (60) bedrooms per acre. There shall be a maximum of three (3) bedrooms in a dwelling unit.
d. Intensity and dimensional standards. All small-scale development in the R district shall comply with the standards in table IV-43: R intensity and dimensional standards.
Table IV-43: R Intensity and Dimensional Standards
Standard[1] | All uses except townhouses | Townhouses
A | Front setback (min) | 10 ft | 10 ft [2]
B | Side setback (min) | 4 ft | 0 ft [3]
C | Rear setback (min) | 10 ft | 10 ft [2]
Notes:
[1] max = maximum; min = minimum; ft = feet
[2] A street-facing garage shall be set back at least 20 feet from the front lot line, and a garage facing a rear alley shall be set back at least 20 feet from the rear lot line.
[3] There is no minimum side setback for townhouses, except a minimum side setback of seven feet is required at each end of a row of townhouses. No townhouse unit shall be less than one-third as wide as it is deep.
[4] The minimum floor to ceiling height for commercial space shall be 12 feet.
[image omitted; see the official code]
e. Development standards. All development in the R and RPD districts (both small-scale and large-scale development) shall comply with the following standards:
1. Site design standards.
i. View of riverfront preserved. To the maximum extent practicable, streets, open space, and buildings shall be located, designed, and oriented to preserve the view of the Black Warrior River and the riverfront from adjacent streets and buildings in the district, and from development directly contiguous to the district located on public streets.
ii. Supplemental zone adjacent to riverwalk. All sites adjacent to the riverwalk shall establish a supplemental zone twenty-five (25) feet in width adjacent to the riverwalk, which serves as an outdoor transitional space between the riverwalk and the development on the site. The supplemental zone may remain in its natural condition or be landscaped, and may include patios, benches, or gazebos. It shall include a pedestrian way that connects the riverwalk to the primary building entrance facing the riverwalk.
iii. Blocks, streets, and alleys. Where streets are added or modified, they should be designed and laid out in blocks with sidewalks, or if that is impractical, with an alternative design that ensures the development provides sidewalks and a pedestrian-friendly environment that is well connected to adjacent streets and sidewalks, and the street and pedestrian system within the district.
iv. Pedestrian circulation system.
(a) Development shall:
(1) Provide sidewalks on both sides of every street. Each sidewalk shall be a minimum of six (6) feet in width, be separated from the street by a street tree planting area at least five (5) feet in width, and have street trees that are located in the street tree planting area and are spaced between forty (40) and fifty (50) feet on center;
(2) Provide sidewalks from building entrances to other sidewalks on the site;
(3) Clearly mark where sidewalks, trails, or other pedestrian ways cross a street or driveway by using a change in paving material, color, or height, decorative bollards, or similar elements; and
(4) When on a site adjacent to the riverwalk, provide a connection to the riverwalk in the form of a defined pedestrian way that is a minimum of eight (8) feet in width, that connects the riverwalk to the primary building entrance on the river-facing side of the building.
(b) All sidewalks shall be surfaced with pavers or imprinted concrete, except in the interior of parks or other less formal areas, where all-weather surfacing may be used.
v. Parking. All off-street parking, except for buildings on a site adjacent to the riverwalk shall be located, to the maximum extent practicable, to the side or rear of principal building(s) as defined by the abutting street. Parking for a building on a site adjacent to the riverwalk shall be located to the side of the building, to the maximum extent practicable, and if that is not possible because of site or other conditions, between the building and the street. Parking to the side of the building shall be screened from the riverwalk by an opaque screen of shrubs that are at least four (4) feet in height at maturity.
vi. Landscaping and fencing.
(a) Transition landscaping shall be provided in the supplemental zone adjacent to the riverwalk. To the maximum extent practicable, existing tree canopy and native vegetation shall be used.
(b) Landscaping and hardscaping shall be designed so it does not interfere with accessibility for persons with disabilities.
(c) Fences are allowed, where necessary for security or privacy reasons. However, the fences shall be designed to not block public access to the riverwalk. Any wall or fence between a building adjacent to the riverwalk and the riverwalk shall not exceed four (4) feet in height, shall have a minimum opacity of fifty (50) per cent, and shall be decorative (chain link fences are prohibited).
vii. Exterior lighting. Light fixtures shall be of a standard ornamental type installed by Alabama Power Company, or a more ornate type of fixture approved by the director of planning to be owned and maintained by the developer or an owners association.
viii. Signs.
(a) Freestanding signs shall be limited to monument signs only.
(b) The maximum allowable sign copy area for signs erected on a building (including on a canopy or awning) on a street frontage or river-facing shall not exceed one square foot per every linear foot of street or river-facing frontage, up to a maximum of eighty (80) square feet per sign. The director of planning may increase the maximum allowable copy area by ten (10) per cent for any building with a building height that is greater than forty (40) feet, if it is demonstrated that the location of the sign and the increase in sign area is done in a way that is compatible with the character of surrounding development and the general purposes of the district.
(c) Channel letter or logo signs placed on the building may be internally lit or back lit, but shall not be lit with neon lighting. All other signs, if lighted, shall be externally lit, internally lit, or translucent box-type signs. Electronic message boards are prohibited.
(d) Painted window signs and backlit or illuminated awnings are prohibited.
(e) Signs on canopies or awnings shall have at least one square foot and no more than three (3) square feet of copy area.
(f) Projecting signs shall comply with the following standards:
(1) For buildings less than forty (40) feet in height:
i. The projecting sign shall not extend above the second floor.
ii. The projecting sign shall have no more than twelve (12) square feet of copy area.
iii. The projecting sign shall not project more than two (2) feet from the building façade, and may extend into a public right-of-way (other than an alley) only with the appropriate city permit.
(2) For buildings forty (40) feet in height or taller:
i. The projecting sign shall have copy area no larger than fifty (50) square feet in area, or one square foot for each linear foot of building frontage, whichever is greater, up to a maximum one hundred (100) square feet of copy area.
ii. The projecting sign shall not project more than three (3) feet from the building face, and may extend into a public right-of-way (other than an alley) only with the appropriate city permit.
(3) Projecting signs shall not display messages on a digital display.
ix. Utilities. All existing and proposed utilities including communication, cable, electric, and the like, shall be installed underground except where such utilities are not visible from any right-of-way. The zoning officer may provide an exception for poles that support only high voltage wires, switches, and transformers.
x. Design of features in flood hazard areas. In flood hazard areas, all structural, landscape, hardscape, and utility features installed at or below the base flood elevation shall be:
(a) Designed to withstand repeated immersion and other predictable effects of flooding with minimum damage and with least maintenance expense;
(b) Designed in a way that is compatible with the color, scale, and architectural elements of the building; and
(c) Where appropriate, screened from view from all streets and the riverwalk.
2. Building design.
i. Building orientation.
(a) The front façade of all new buildings, as defined by the primary entrance, shall be oriented and front onto a street, a courtyard, or plaza.
(b) For a building on a site contiguous to the riverwalk, there shall also be a primary entrance on the façade of the building facing the riverwalk, unless topographical features make it infeasible.
(c) All single-building developments shall be configured with the long axis of the building parallel to the street it fronts, or be consistent with existing development patterns, rather than being sited at unconventional angles, to the maximum extent practicable.
(d) The primary entrances of buildings in a multi-building development shall:
(1) Be oriented towards a street along the perimeter of a development, or towards streets or driveways interior to the development; and
(2) If appropriate, frame the corner of adjacent street intersections or entry points.
ii. Entrances.
(a) All buildings facing a primary street shall provide a primary pedestrian entrance from the primary street.
(b) All buildings on a site contiguous to the riverwalk shall provide a primary pedestrian entrance from the riverwalk unless topographical features make it infeasible.
(c) All primary pedestrian entrances into principal buildings from both the street and the riverwalk (where applicable) shall be clearly defined and emphasized using changes in the wall plane or façade material, lintels, pediments, pilasters, arches, awnings, canopies, porches, or other architectural elements.
(d) For all sites adjacent to the riverwalk, a street address number shall be located directly above or beside the primary building entrance from the riverwalk, and be visible from the riverwalk.
iii. Façades.
(a) Building façades facing the riverwalk shall provide views of the riverwalk and riverfront through the use of windows, doors, terraces, balconies, or other architectural features.
(b) The street-facing and river-facing side of a building, where visible off-site along a street or the riverwalk, shall be articulated with the same façade details as provided on the building's street-facing or river-facing façade.
(c) Outbuildings located in front or behind other buildings within the same development shall include a consistent level of façade articulation and architectural detail on all sides of the building, as well as exterior materials and colors that are compatible with the primary building in the development.
iv. Fenestration/transparency.
(a) A minimum of thirty-five (35) per cent of the street-facing facade area of the ground-level floor of non-residential or mixed-use buildings (as measured from the grade to the underside of the eave, top of the parapet, or the story line denoting the second floor) shall be occupied by windows or doorways.
(b) A minimum of thirty-five (35) per cent of the river-facing facade area of the ground-level floor of non-residential or mixed-use buildings (as measured from the grade to the underside of the eave, top of the parapet, or the story line denoting the top floor) shall be occupied by windows or doorways.
v. Roofs. Buildings shall use a common, unifying design for roofs in terms of roof type, pitch, color, and materials. The intent of this requirement is not to create a uniform appearance, but rather a distinct sense of place.
vi. Loading, service, dumpster, mechanical and other equipment areas.
(a) Loading, service, dumpster, and mechanical and other equipment areas shall be located in a manner that screens their visibility from adjacent streets and the riverwalk.
(b) Loading, service, dumpster, mechanical and other equipment areas, and other similar facilities shall not be oriented toward the riverwalk.
(c) Outdoor storage areas shall be fully screened from adjacent streets, the riverwalk, and single-family detached dwellings.
3. Building materials.
i. Primary materials.
(a) The following building material shall be used for not less than seventy-five (75) per cent of the building wall surface area on each façade. Primary material changes may occur only at building corners where a maximum of one of the façades faces the street:
(1) Brick masonry.
(2) Natural stone (or synthetic equivalent), such as limestone, granite, and marble;
(3) Wood-clapboard or shingles;
(4) Cementitious siding; or
(5) Glass curtain wall.
(b) The use of EIFS or aluminum siding is prohibited.
ii. Accent materials. The following materials may make up twenty-five (25) per cent of the building wall surface area on each façade:
(a) Pre-cast masonry (only for trim and cornice elements);
(b) Gypsum reinforced fiber concrete—GFRC (for trim elements only);
(c) EIFS only for trim;
(d) Metal (for beams, lintels, trim elements, and ornamentation);
(e) Split-faced block (only for piers, foundation walls, and chimneys);
(f) Glass block;
(g) Vinyl shakes or shingles;
(h) Vinyl clapboard (with a minimum thickness of 0.044 inches); and
(i) Stucco (panels with cementitious finish, not tiles or EIFS—external insulation finishing system).
iii. Alternative materials. Alternative building materials not listed in subsections i. and ii. above may be approved if the director of planning determines that the alternative materials are equivalent or better than the listed materials. The use of regionally-available materials is preferred.
4. Utilities. All existing and proposed utilities including communication, cable, electric, and the like, shall be installed underground except where such utilities are not visible from any right-of-way. The zoning officer may provide an exception for poles that support only high voltage wires, switches, and transformers.
f. References to other standards. Development in the R district shall comply with all applicable standards of this zoning ordinance and the subdivision regulations, including but not limited to the standards referenced in table IV-44: Cross-references to other standards, unless they conflict with the standards of the R district. In case of conflict between the standards of the R district and the other applicable standards of the zoning ordinance or subdivision regulations, the standards of the R district shall control.
Table IV-44: Cross-References to Other Standards
Section | Standard
Article VI, Division 1 | Mobility and Connectivity Standards
Article VI, Division 2 | Off-Street Parking, Bicycle Parking, and Loading Standards
Article VI, Division 3 | Landscape and Buffer Standards
Article VI, Division 5 | Fence and Wall Standards
Article VI, Division 6 | Exterior Lighting Standards
Article VI, Division 7 | Neighborhood Compatibility Standards
Article VI, Division 8 | Form and Design Standards
Article VI, Division 9 | Green Building Incentives
Article VI, Division 10 | Signs and Billboards
Subdivision Regulations