For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 27-211.2.5 — General District Development Standards for Seminole Heights - Commercial Neighborhood (SH-CN) district

Code of Ordinances, City of Tampa (Supp. No. 148: codified through Ordinance No. 2025-152, enacted December 18, 2025) · Tampa City Code § 27-211.2.5

Corpus is an independent public-information project, not the official City of Tampa website. Stable reference: corpuslaw.us/code/51743784-fe9a-464b-8d74-659ca9fbbddc

Sec. 27-211.2.5. - General District Development Standards for Seminole Heights - Commercial Neighborhood (SH-CN) district.

(a) Building placement, form, and layout standards: all development shall comply with development standards set forth below. Single-family detached residential shall adhere to the development standards of SH-RS. Semi-detached, attached, and two-family residential shall adhere to the development standards of SH-RS-A. Multi-family residential shall adhere to the development standards of SH-RM: Graphic 211.2.5a [image omitted; see the official code] KEY (SH-CN): Table 211.2.5a See also Sec. 27-43 Definitions | PB: Principal building AB: Accessory building BTL: Build-to-line | F: Front SS: Side (street) SI: Side (Interior) R: Rear | FB: Front Building Form SSB: Side (street) Building Form | SF: Square Feet min: minimum Building Placement (PB) | Building Placement (AB) BTL [1, 3] | Setback [4] F | 10' | F | 10' SS | 10' | SS | 10' Setback [2, 4] | Setback [4] SI | 0' | SI | 0' R | 15' | R | 15' Building Form | Building Form FB | 35% min [5] | FB | N/A SSB | 15% min [5] | SSB | N/A Lot Configuration [6] Lot Width | 60' min | Lot Area | 6000 SF min [7] Notes: [1] Build-to-line: required line/location at which the building wall shall be placed. [2] Canopies, awnings, fireplaces, arcades, trellises, pergolas, and other architecturally integrated façade features may be placed at three (3) feet setback. See Map SH-25.2 for additional encroachment allowances, when applicable. [3] Building façades along front BTL must have functioning ground floor entrance. Rear-only facing buildings are prohibited. [4] Setback: the line/location that sets the minimum distance at which the building wall may be placed. [5] Minimum % of building façade (ground floor) shall be built at required BTL. [6] A lot of record established prior to July 1, 2010, shall be allowed to develop, subject to the regulations set forth in this article. [7] For those properties within designated nodes per the Greater Seminole Heights Vision Plan & the Tampa Comprehensive Plan, refer to 27-211.15. (b) Use and general building standards: all development shall comply with development standards set forth below: Graphic 211.2.5b Depicts an example of a 1-story, 2-story, and 3-story office cross-section. [image omitted; see the official code] KEY (SH-CN): Table 211.2.5b See also Sec. 27-43 Definitions | GF: Ground Floor UF: Upper Floor PBH: Principal building height ABH: Accessory building height | SF: Square feet PW: Parapet wall UFA: Usable floor area min: minimum Use Placement GF | Office/private institutional, governmental/public institutional UF | Office/private institutional, governmental/public institutional, residential Maximum Height [1] PBH | 3 stories (45 feet) ABH | 2-stories (25 feet) [2] PW | 7' above PBH and ABH [4] Elevator/mechanical housing, steeples, flag poles, widow's walk, cupolas, other architecturally integrated design features. | Exempt, except shall occupy no more than 20 percent of roof area. Miscellaneous Standards Minimum transparency, such as architectural features or elements as defined in Sec. 27-43, window boxes, doors and windows, for nonresidential façades along FB and SSB, measured within first 15' (from grade) of the façade. | 30 percent for all non-residential uses Maximum allowable aluminum, other metal siding, or plastic/PVC that can be used on any Front or Side Street façade [3] | 25 percent Notes: [1] Height is measured from finished grade to highest point of structure (see Sec. 27-43 Definitions). [2] ABH shall be reduced to 2-story (22.5 feet maximum) when located within 20 feet of a 1-story residential principal building (not located on subject parcel). [3] Aluminum, other metal siding, or plastic/PVC materials shall only be used as accent or ancillary materials. [4] PW maximum of 7' above maximum height for PBH and ABH for decorative and screening purposes. (c) Parking placement, layout, and general ratio standards: all development shall comply with development standards set forth below: Graphic 211.2.5c [image omitted; see the official code] KEY (SH-CN): Table 211.2.5c See also Sec. 27-43 Definitions | F: Front SS: Side (street) SI: Side (Interior) R: Rear | SF: Square Feet UFA: Usable Floor Area Parking Placement (location of parking space(s)) [2, 3] Setback F | 15′ SS | 15′ SI | 3′ [1] R - Adjacent to/separated by alley from detached or attached residential use - Adjacent to any other use (no alley) - Adjacent to any other use (separated by alley) | 8′ 3′ [1] 5′ Required Spaces (see Table SH-25.1 for other permitted uses) | Minimum Ratio (spaces per unit) (see Table 211.12 for other ratios by use) Office, business-professional | 3 / 1000 SF (UFA) Office, medical | 5 / 1000 SF (UFA)) Notes: [1] Parking (pavement) setback may be reduced to 0′ for shared access and parking areas. [2] 80% of onsite parking shall be located to the side or rear of the principal building. [3] Structured parking (when applicable): Façades of garages must be architecturally embellished and integrated with the overall design of the development on all sides visible to right-of-way.

(Ord. No. 2011-45, § 1(Exh. B), 3-24-2011; Ord. No. 2025-141, § 8, 12-4-2025)

Ask a question about Tampa law

Corpus searches the Tampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.