Sec. 74.140. - Installation and maintenance waste monitoring facilities.

(a) All devices, access facilities, and related equipment shall be installed by the person discharging the waste at the person's expense and shall be maintained by the person in a safe and proper operating condition at all times, readily accessible to the Director during all times the industry is operating. (b) The flow measurement device shall be a Parshall flume, or other flow measurement device acceptable to the Director, providing accurate and continuous flow indication, but in no case shall pump timers or other indirect measurement devices be used for flow measurement. (c) The flow meter shall indicate and total the flow in millions of gallons per day with an error not exceeding plus or minus two percent. The meter shall be equipped with a set of electrical contacts arranged to momentarily close a circuit to energize the sampling device which will take a minimum of 50 samples per operating day. Other control variations will be acceptable if it can be demonstrated that the sampling procedure will result in a waste sample which is proportional to the waste flow. In no case shall the daily collected sample be less than two liters in volume. (d) The method of sampling used may be by continuous pumping past a solenoid-operated diversion valve, direct pumping into the sample container, continuous pumping past a sampler dipper calibrated to remove a constant sample, by a proportionate dipper sampler operating directly in the waste flow, or by any other approved means. The sample collection pipe or dipper cup shall be sized according to waste characteristics and approved by the Director and the sample pump shall have a minimum capacity of three gallons per minute. The sample line shall not be interconnected to any other piping system. All samples must be continuously refrigerated at a temperature between one degree centigrade and four degrees centigrade (34 degrees Fahrenheit and 39 degrees Fahrenheit). (e) The area for installation of the measuring and sampling equipment, pH monitoring system, and sample storage shall be fully enclosed, locked and protected from tampering and keys provided to the City. All measuring and sampling equipment shall be serviced and calibrated at least twice annually by a qualified independent technician approved by the Director, with one service calibration to be done not more than two weeks prior to the peak season for seasonal processors. Maintenance, repair, replacement, or additional equipment needed to accurately monitor waste discharge shall be provided at the sole cost of the user. A clean sample container shall be supplied daily to the City sample collector to place in service. (f) All pH monitoring probes shall be cleaned as required by the Director. (g) All sampling hoses, devices including valves and sample splitters, holding vessels and refrigerators used for holding or storing samples shall be cleaned and maintained so as to ensure true and accurate composite samples. (h) The flow measurement, pH monitoring, and sampling stations shall be located and constructed in a manner acceptable to the Director. Complete plans on all phases of the proposed installation, including all equipment proposed for use, shall be submitted to the Director for approval prior to construction. Construction shall be completed within 90 days following notification of approval by the City. (i) There shall be sufficient room in or near the sampling station to allow accurate sampling and preparation of samples for analysis. (j) The user discharging the waste shall keep flow records required by the Director and shall provide qualified personnel to properly maintain and operate the facilities. (k) Calibration of flow meters, pH recorders, and samplers shall be performed at least twice annually by a qualified technician or at such intervals as may be required by the Director. Maintenance and calibration adjustments shall be recorded daily and records shall be readily available to City inspectors. City inspectors may check calibration of flow and pH instruments. An approved electrical outlet shall be provided near the user's sample equipment for City equipment. (l) Maintenance schedules shall be made available to City inspectors, including, but not limited to, schedules for: (1) Cleaning sample collection tubes and containers; (2) Operating the sample refrigeration system; (3) Cleaning screening equipment; and (4) Calibrating pH probes and chemical feed equipment. (m) pH monitoring and control equipment shall be of a type approved by the Director and shall be equipped with a circular or strip chart recorder. The recording for pH monitoring shall show a minimum of 24 hours of data with indication of the presence or absence of flows.

(Prior Code, § 74.140; Ord. No. 13-96; Ord. No. 65-2002)

Ask a question about Salem law

Corpus searches the Salem sections it holds and shows the ones that match, with their citations. Free, no sign-in.