IBC BUILDING CODE AMENDMENT, SECTION 1605.2, LOAD COMBINATIONS USING STRENGTH DESIGN OR LOAD AND RESISTANCE FACTOR DESIGN, ADD EXCEPTION 3
Boise City Code § 9-1A-53
in effect9-1A-53: IBC BUILDING CODE AMENDMENT, SECTION 1605.2, LOAD COMBINATIONS USING STRENGTH DESIGN OR LOAD AND RESISTANCE FACTOR DESIGN, ADD EXCEPTION 3:
Add exception 3 to section 1605.2 as follows:
3. In Equation 16-3, the snow load S shall be calculated using pm as defined in Section 1608.1. For other load combinations involving snow loads, S shall be calculated using flat roof snow load (pf) or sloped roof snow load (ps) as defined in ASCE 7.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
Source: Boise City, Idaho, City Code and City Charter (American Legal Publishing, codelibrary.amlegal.com)URL: https://codelibrary.amlegal.com/codes/boise_id/latest/boise/0-0-0-36918Fetched: 11/1/2026