Orlando City Code § 61.240 Standards for Construction of Driveway Approaches, Curbcuts, Driveways and Similar Alterations.
Sec. 61.240. - Standards for Construction of Driveway Approaches, Curbcuts, Driveways and Similar Alterations.
Applicability. The following section of Code applies citywide. Parcels within the Southeast Sector may be subject to alternative Standards found in Sec. 68.312 entitled Additional Standards by Residential Building Type.
Except where specific approval is granted by the Public Works Director due to unique and peculiar circumstances or needs resulting from the size or location of property requiring a modification of standards as set forth below, the minimum standards for the construction of driveway approaches, curbcuts, driveways and other similar alterations shall be as follows:
Width (Residential Except Multifamily). In properties developed for residential use (except multifamily), curbcuts and driveway approaches shall conform to the following, as illustrated in Figure 6-A for residential driveways:
Use Type | Minimum Curbcut (a) | Minimum Driveway Width (b) | Maximum Driveway Width (b)
Standard driveway for single-family, duplex and tandem | 13 ft. | 7 ft. | 18 ft.
Ribbon Driveways for single-family, duplex and tandem | 13 ft. | 2 ft. Per Ribbon & 7 ft. overall (c) | 10 ft. (c)
Townhome (d)(e) | See Sec. 58.511.A.10 | 24 ft.
Multiplex (d)(e) | See Sec. 58.562.K | 24 ft.
Multifamily (d)(e) | 24 ft.; Min. Radius: 15—25 ft. | 20 ft. | 30 ft.
Non-residential (d)(e) | 24—36 ft.; Min. Radius: 25 ft. One-way: 16 ft. | 20 ft. | 30 ft.
(A) The width of all curbcuts shall include two, three-foot wide (minimum) flares, or transitions, on each side of the driveway as shown on Figure 6-A.
(B) This width shall be as measured at the property line. If the driveway is wider within the parcel than at the property line, the transition must be accomplished with a straight or curved taper nominally designed at a 45 degree or greater angle. The space adjacent to the taper must be landscaped and may not contain gravel, mulch, wood chips, or other materials subject to decay.
(C) Measured from the outside edges of the two ribbons. The area between the ribbons must be grass or vegetated material and is considered pervious.
Other requirements (Residential except multifamily). For duplex and tandem building sites, driveways cannot create a "Y" or "tuning fork" shape as shown in Figure 6-C.
(D) Unless an AutoTurn analysis provided at the time of permitting demonstrates the need for a greater return radius. In dense urban areas of the City, appropriate flares may be substituted for the return radius if approved by the City Transportation Engineer or their designee.
(E) Except that where separate driveways are provided for one way traffic, then such driveway approaches may be permitted with a width of not less than 16 feet based on a straight-line transition in accordance with Figure 6-B.
Figure 6-A. Single-Family, Duplex and Tandem Driveways
[image omitted; see the official code]
Figure 6-B. Non-Residential and Multifamily Driveways
[image omitted; see the official code]
FIGURE 6-C—TUNING FORK DRIVEWAY
[image omitted; see the official code]
Measurement Rules. In measuring the width of curbcuts, the distance shall include the transitional slope, radius or straight line, as applicable, from the high curb line to the lowest point of such curbcut.
Distance from Drainage Inlet. No curbcut shall be made within three feet of a drainage inlet.
Distance from Side Property Lines. The flare or return radius for any driveway may not extend in front of neighboring parcels unless approved prior to permitting by the City Transportation Engineer or their designee. The flare must be set back 1 ft. from the extended side property line. See Exhibit 6-A.
Separation between Curbcuts. Curbcuts on all streets listed in the Major Thoroughfare Plan (Table 3) must be separated from adjacent curbcuts or intersections according to the standards set forth in Chapter 61, Sec. 212-214 and the Engineering Standards Manual.
Number of Curbcuts on One Building Site. Each building site is allocated one curbcut in a location determined by the City Transportation Engineer. Single-family residential properties may have a second curbcut on a street frontage if all requirements in Sect. 61.300—61.302 are met. Non-residential and multifamily developments may have a second curbcut on a street frontage if all requirements in Ch 61 Part 1 and Part 2 are met.
Vehicle Standing in Right-of-Way Prohibited. Driveways shall be so arranged, constructed and maintained that automobiles, trucks, trailers and other vehicles will not stand upon any part of the sidewalk and/or parkway at any time when the same are being loaded, unloaded, serviced or parked.
Sidewalk Section. All driveway approaches constructed in the City shall contain a sidewalk section of the width and grade and minimum construction standards established in the Engineering Standards Manual for sidewalks in such area except where the distance between the street and the right-of-way line is ten feet or less, in which case the driveway will be sloped from the right-of-way line to the street. The width of the re-enforced portion of the sidewalk must equal or exceed the width of the driveway as measured at the property line.
(Ord. of 9-16-1991, Doc. #25098; Ord. of 7-26-1993, Doc. #26770; Ord. of 3-17-1997, Doc. #30125; Ord. No. 2017-17, §8, 4-10-2017, Doc. #1704101203; Ord. No. 2022-45, § 2, 8-15-2022, Doc. #2208151209)