§149.0902 Local Additions and Modifications to Section R902.1 “Roof Classification” of the California Residential Code
(a) Section R902.1 is adopted by reference and modified by adding Section R902.1.4 as follows: (1) R902.1.4 Roof Assemblies. All newly constructed roofs shall be covered with a fire-retardant roof covering that is at least Class “A” and the roof classification shall be demonstrated based on the requirements in the California Residential Code. (2) R902.1.4.1 The entire roof shall be covered with a fire-retardant roof covering that is at least Class “A” where a building addition is more than twenty-five percent of the original floor area of the building. (b) Section R902.2 is adopted by reference and modified by adding Sections R902.2.1 and R902.2.2 as follows: (1) R902.2.1 Wood Shingles. Wood shingles are not permitted, except as provided in the California Historical Building Code Section 8-408 and San Diego Municipal Code Section 149.0908. (2) R902.2.2 Wood Shakes. Wood shakes are not permitted, except as provided in the California Historical Building Code Section 8-408 and San Diego Municipal Code Section 149.0908. (c) Section R902.3 is adopted by reference and modified as follows: R902.3 Building integrated solar photovoltaic (BVIP) systems. Integrated solar photovoltaic (BVIP) systems that serve as the roof covering shall be listed and labeled for fire classification in accordance with UL 7103 for the fire classification determined in accordance with Section 149.0902(a) of the Land Development Code. (d) Section R902.4 is adopted by reference and modified as follows: R902.4 Rooftop mounted solar photovoltaic panel systems. Rooftop mounted photovoltaic panel systems installed on or above the roof covering shall be tested, listed and identified with a fire classification in accordance with UL 2703. When located in the Very High Fire Hazard Severity Zone Map – Local Responsibility Areas adopted pursuant to Section 511.0301(a) of the San Diego Municipal Code, roof-top mounted photovoltaic panel systems shall have a minimum fire classification rating of Class A.
(“Local Additions and Modifications to Section R902.1 “Roof Classification” of the California Residential Code” added 7-31-2012 by O-20187 N.S.; effective 8-30-2012.) (Amended 4-6-2016 by O-20624 N.S.; effective 5-6-2016.) (Amended 1-18-2018 by O-20897 N.S.; effective 2-17-2018.) (Amended 4-9-2020 by O-21181 N.S.; effective 5-9-2020.) (Amended 5-8-2023 by O-21642 N.S.; effective 6-7-2023.) (Amended 3-23-2026 by O-22080 N.S.; effective 4-22-2026.)
Ask a question about San Diego law
Corpus searches the San Diego sections it holds and shows the ones that match, with their citations. Free, no sign-in.