Sec. 118-243. - Grease trap size.
(a) The size of the grease trap shall be determine[d] from the following formula for facilities that serve meals: GT = M × G GT = grease trap size in gallons. M = meals served during the mealtime period in which the greatest number of patrons are served. G = gallon multiplier. If one mealtime is served per day, the multiplier is 205; if two mealtimes are served per day, the multiplier is three; if three mealtimes are served per day, or the facility is open to the public for meals more than 12 hours in a 24-hour period, the multiplier is five. (b) Facilities that do not serve meals shall install a grease trap with a volume at least 300 percent greater than the monthly total volume of FOG produced by the facility. (c) In the event that the size of the grease trap cannot be determined from subsection (a) [or] (b) [o]f this section, the facility shall establish the size of the grease trap based on the best evidence available. Upon approval of the size of the grease trap by the sanitary board, the existing facility shall obtain a grease trap permit then install a grease trap of the approved size. In no case shall the grease trap have a flow rate less than 30 gallons per minute, or have capacity less than 60-pound of grease. (d) The sanitary board may exempt a facilities from the requirements of this article if the owner/operator of the facility demonstrates to the satisfaction of the sanitary board that its wastewater will not contain FOG in excess of 200 milligrams per liter. A written request for an exemption shall be made to the sanitary board. A detailed description of the activity performed by the facility, a copy of the menus, and a list of kitchen equipment (number of sinks, dishwater, fryer, etc.) shall be attached to the written exemption request. The owner and/or operator of the facility is required to notify the sanitary board in writing of changes to the business operation or menus after receiving an exemption. The sanitary board reserves the right to require installation of a grease trap at any time. (e) The sanitary board may modify the requirements for the size of the grease trap, as calculated is subsection (a), (b), or (c) of this section, for good cause, including, but not limited to, restrictions in the space for installation of a grease trap.
(Bill No. 6876, § 25-57, 2-19-2002)
Ask a question about Charleston law
Corpus searches the Charleston sections it holds and shows the ones that match, with their citations. Free, no sign-in.