§ 94.35 — Multi-dwelling units alarm system specifications

Code of Ordinances, City of Springfield, Illinois (Supp. No. 82: codified through Ordinance No. 146-04-26, enacted April 7, 2026) · Springfield, Ill., City Code § 94.35

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/569c7feb-c47a-4806-b049-7cca946843ef

§ 94.35. - Multi-dwelling units alarm system specifications.

(a) All newly constructed multi-dwelling units or any existing multi-dwelling units which meet any of the following criteria, shall require a fire alarm system following the specifications of section (b) below: (1) Thirteen dwelling units or more. (2) Four stories or more (a story equals any level with more than 50% of its height above any perimeter grade, measured interior ceiling to floor). (3) Three stories or less where direct exterior exiting is not available from each dwelling unit. (b) The owner or his agent of any newly constructed multi-dwelling unit or any existing multi-dwelling unit that is being altered, repaired, or remodeled under a building permit showing the cost of such to exceed $1,000, and which meets the criteria set forth in subsection (a) shall install a fire alarm detection system consisting of: (1) Fixed temperature detectors in the attic, storage, equipment, and furnace room. (2) Rate of rise fixed temperature detectors in the basement or cellar; or a fixed temperature detector that meets the requirements of NFPA Standard 72, 2019 edition. Spacing shall meet the requirements of NFPA 72 section 17.6.3. (3) Photoelectric smoke detectors in each corridor according to the manufacturers listed coverage. (4) A photoelectric smoke detector on the ceiling at the top of any stairway that is enclosed at the top landing. (5) Audible and/or visual fire alarm devices as required to notify all building occupants. (6) An outside weatherproof audible and visual fire alarm device with a sign placed by the horn reading: Fire Alarm—Call 911. (7) Pull stations at points of egress and other areas where circumstances dictate as determined by the fire safety division. (8) An annunciator panel designed to indicate location of alarm by floor or other area identified by the fire safety division during the plan review. (9) A fire alarm control panel with approved emergency power. (10) A single station smoke detector in each room designated by the fire safety division during the plan review. Smoke detection for newly constructed or altered multi-dwelling units shall meet the provisions set forth in the International Fire and Building Code 2018 editions. (c) Multi-dwelling units that are fully sprinklered shall be required to have a fire alarm detection system consisting of the components listed in the International Fire Code, 2018 edition, chapter 903. (d) All fire alarm systems that meet any of the following criteria shall be connected to an approved central or remote station: (1) Located in the fire district. (2) Four stories or more (a story equals any level with more than 50% of its height above any perimeter grade, measured interior ceiling to floor). (3) Thirteen units or more. (e) Carbon monoxide detectors are required per the provision of the Carbon Monoxide Alarm Detector Act, Illinois Compiled Statutes (430 ILCS 135) enacted January 1, 2007, as well as the provisions set forth in the International Fire and Building Code, 2018 edition.

(Ord. No. 190-04-06, § 1(Exh. A), 4-4-06; Ord. No. 489-07-07, § 1(Exh. A), 7-17-07; Ord. No. 056-02-23, § 1(Exh. A), 2-21-23)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.