Sec. 49-1521. - Meters.

The following provisions shall apply to water meters: (a) All water meters installed within buildings shall be at least a three-fourths inch meter, positioned horizontally at a height where they may be easily read, and located as near as possible to the point where the water service enters the building. (b) One inch and smaller meters shall be sized in accordance with Table 49-1521(b): Table 49-1521(b) Meter Size (inches) | Maximum GPM ⅝ | 10 ¾ | 15 1 | 26 * Exception: individual apartments (R1 and R2 occupancy with 20 fixture units or less) shall be served by at least a five-eighths inch meter. Apartments with 21 to 40 fixture units shall be served by at least a three-fourths inch meter. All individual apartments units with more than 40 fixture units shall be sized using Table 49-1521b. (c) Meter sizes on services larger than one inch (and connected to Metropolitan Utilities District mains) shall be determined by district regulations. All other sizes shall follow Table 49-1521(c): Table 49-1521(c) Meter Flow Gallons Per Minute Meter Size | Continuous 1 ½" disc | 50 2" disc | 80 3" comp | 160 4" comp | 250 2" turbo | 160 3" turbo | 350 4" turbo | 1,000 6" turbo | 2,000 (d) Meter sizes 1½-inches and larger shall be positioned as follows: (1) Installed level in a horizontal position not more than 24 inches above the floor. (2) Allow at least 18-inch clearance above and 18-inch clearance from any wall. (3) Provide a clear space (to allow for servicing and testing) in front of the meter at least 30 inches by 30 inches by six feet high. (4) Shall not be suspended nor supported by piping. (5) Installed so the test tee (provided for meter testing) is no more than 50 feet from an adequate floor drain, sump pump or access to the outside. Table 49-1521(d) shall be used to determine the floor drain or sump pump size required to receive the volume from a test tee when testing a meter: Table 49-1521(d) Volume of Water Used in Testing Water Meters Meter Size | Drain or Sump Pump Capacity 1½-inch | 50 gallons per minute 2-inch | 80 gallons per minute 3-inch | 150 gallons per minute 4-inch and 6-inch | 200 gallons per minute 8-inch and larger | 400 gallons per minute (e) The maximum pressure (head) loss for a meter shall be 15 pounds.

(Ord. No. 40524, § 1, 10-20-15)

Ask a question about Omaha law

Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.