INSPECTION, SAMPLING AND ANALYSIS
Colorado Springs City Code § 12.5.903
in effect12.5.903: INSPECTION, SAMPLING AND ANALYSIS:
A. Utilities Sampling: Sampling of industrial wastewater for the pollutants determined to be present in the user's process for the purpose of determining compliance with respect to the prohibitions and limitations of part 7 of this article will be performed by Utilities at intervals as the Chief Executive Officer may designate. However, it is the requirement of this section that the Chief Executive Officer conduct sampling or cause the sampling to be conducted for all significant industrial users in accord with methods contained in 40 CFR section 136, or approved alternative methods, at least once per year.
B. Industrial User Sampling:
1. For Reports Required By Subsections 12.5.901C, D And E Of This Part: The reports required by subsections 12.5.901C, D and E of this part must be based upon data obtained through appropriate sampling and analysis performed during the period covered by the report, which data are representative of conditions occurring during the reporting period. The Chief Executive Officer shall require that frequency of monitoring necessary to assess and assure compliance by industrial users with applicable pretreatment standards and requirements. Grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide, and volatile organic compounds. For all other pollutants, twenty four (24) hour composite samples must be obtained through flow proportional composite sampling techniques, unless time proportional composite sampling or grab sampling is authorized by the Chief Executive Officer. Where time proportional composite sampling or grab sampling is authorized by the Chief Executive Officer, the samples must be representative of the discharge and the decision to allow the alternative sampling must be documented in the industrial user file for that facility or facilities. Using protocols (including appropriate preservation) specified in 40 CFR section 136 and appropriate EPA guidance, multiple grab samples collected during a twenty four (24) hour period may be composited prior to the analysis as follows: for cyanide, total phenols, and sulfides the samples may be composited in the laboratory or in the field; for volatile organics and oil and grease the samples may be composited in the laboratory. Composite samples for other parameters unaffected by the compositing procedures as documented in approved EPA methodologies may be authorized by the Chief Executive Officer, as appropriate.
2. For Reports Required By Subsections 12.5.901C And D Of This Part: For sampling required in support of baseline monitoring and ninety (90) day compliance reports required in subsections 12.5.901C and D of this part, a minimum of four (4) grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide and volatile organic compounds for facilities for which historical sampling data do not exist. For facilities for which historical sampling data are available, the Chief Executive Officer may authorize a lower minimum.
3. For Reports Required By Subsections 12.5.901E And F Of This Part: For the reports required by subsections 12.5.901E and F of this part, the Chief Executive Officer shall require the number of grab samples necessary to assess and assure compliance by industrial users with applicable pretreatment standards and requirements. If an industrial user subject to the reporting requirement in subsections 12.5.901E and F of this part, monitors any regulated pollutant at the appropriate sampling location more frequently than required by the Chief Executive Officer, using the procedures prescribed in subsection C of this section, the results of this monitoring shall be included in the report.
4. Recordkeeping Requirements: Any industrial user subject to the reporting requirements established herein shall maintain records of all information resulting from any monitoring activities required by this section, including documentation associated with Best Management Practices. Such records shall include for all samples:
a. The date, exact place, method, and time of sampling and the names of the person or persons taking the samples;
b. The dates analyses were performed;
c. Who performed the analyses;
d. The analytical techniques/methods used; and
e. The results of such analyses.
C. Laboratory Analysis: Laboratory analysis of industrial wastewater samples shall be performed in accord with 40 CFR section 136, or other methods approved by the Chief Executive Officer. Analysis of those pollutants not covered by these publications shall be performed in accord with procedures approved by the Chief Executive Officer. The test results of laboratory analysis performed by Utilities in accord with this section shall be presumed to be correct unless shown otherwise by competent evidence. Test methods selected shall be those most representative and precise for the concentrations in the effluent limitations.
D. Compliance Determinations: Compliance determinations with respect to the prohibitions and limitations of part 7 of this article shall be made on the basis of either instantaneous compliance samples or composite samples of wastewater as determined by the Chief Executive Officer. The samples shall be taken at a point or points which the Chief Executive Officer determines to be suitable for obtaining a representative sample of the discharge. Composite samples may be taken over a twenty four (24) hour period, or over a longer or shorter time span, as determined by the Chief Executive Officer to meet specific circumstances.
E. Industrial User Extra Monitoring: If effluent self-monitoring performed by an industrial user indicates a violation of limitations contained in the user's permit or contained in applicable categorical pretreatment standards, the users shall repeat the sampling and analysis for the pollutant(s) that was in violation within seven (7) days of becoming aware of the violation. The industrial user is not required to perform this extra monitoring if the user is adhering to an approved compliance schedule. Where the Chief Executive Officer has performed the sampling in lieu of the industrial user, the Chief Executive Officer must perform the repeat sampling and analysis unless it notifies the user of the violation and requires the user to perform the repeat analysis. Resampling is not required if:
1. The Chief Executive Officer performs sampling at the industrial user at a frequency of at least once per month; or
2. The Chief Executive Officer performs sampling at the industrial user between the time when the initial sampling was conducted and the time when the user or the Chief Executive Officer receives the results of this sampling.
F. Rules, Regulations And Procedures For Samples: The Chief Executive Officer shall promulgate rules, regulations and procedures as necessary to ensure that any and all samples obtained by Utilities' employees can be accounted for from the time the samples are obtained to the time the samples are disposed.
G. Tampering Unlawful: Tampering with or purposely rendering inaccurate any monitoring device method, or record required to be maintained by this article is unlawful. (Ord. 98-173; Ord. 99-162; Ord. 01-42; Ord. 10-82; Ord. 14-66; Ord. 18-42)
Source: City of Colorado Springs, Colorado, City Code and City Charter (American Legal Publishing, codelibrary.amlegal.com)URL: https://codelibrary.amlegal.com/codes/coloradospringsco/latest/coloradosprings_co/0-0-0-20812Fetched: 11/1/2026