For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.34.040 — SP-1 General Development Standards

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 17.34.040

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/586284e1-06b0-42c8-bdfd-48c0d5bfdc5f

17.34.040 - SP-1 General Development Standards

Subdivisions, new land uses and structures, and alterations to existing land uses and structures shall be designed, constructed, and established in compliance with the requirements in Table 3-15.1 in addition those in Section 17.34.050 (SP-1 Additional Development Standards), and the applicable standards (e.g., landscaping, parking and loading, etc.) in Article 3 (Site Planning and General Development Standards). For residential projects, see 17.34.060 (SP-1 Residential Development Standards). The development standards of the base zoning districts shall not apply. TABLE 3-15.1 - NORTH LAKE SPECIFIC PLAN DEVELOPMENT STANDARDS Development feature | Requirement by Zoning District SP-1a | SP-1b | SP-1c | SP-1d | SP-1e Minimum lot size | Minimum area and width for new parcels. Minimum area | 7,200 sf | As determined through the subdivision process consistent with the General Plan | 7,200 sf | As determined through the subdivision process consistent with the General Plan Width | 55 ft | 55 ft Maximum density (1) | Minimum lot area in square feet required for each dwelling unit. See Section 17.34.060 for the applicable residential development standards. 2,750 sf | 1,360 sf | N.A. | 910 sf Setbacks | See Section 17.40.160 for setback measurement, allowed projections and encroachments into setbacks, and exceptions to setbacks. Front | 20 ft minimum (2) | 5 ft - fixed (3) (4) | 5 ft - fixed (3) (4) | 5 ft - fixed (3) (4) | 5 ft - fixed (3) (4) Sides | 7 ft | N.A. | N.A. | N.A. | N.A. Corner side | 15 ft | 5 ft (4) | 5 ft (4) | 5 ft (4) | 5 ft (4) Rear | (5)(6) | (7) | (7) | (7) | (7) Encroachment plane | Structures shall not be located within an encroachment plane. See Section 17.40.160 for allowed projections into encroachment planes. Adjoining a residential property line | 30-degree angle eight feet above the existing grade at the property line of abutting residential use. | 45-degree angle eight feet above the existing grade at the property line of the abutting residential use Height limit | Maximum height of main structures at points noted. See 17.40.060 for height measurement, and exceptions to height limits. 30 ft non- residential including mixed- use | 30 ft non- residential/ 42 ft. mixed use (8) (9) | 25 ft non- residential/ 37 ft mixed- use (9) | 30 ft (8)(9) | 36 ft non- residential/ 48 ft mixed- mixed-use (9) Accessory structures | See Section 17.50.250 (Residential Accessory Uses and Structures) Landscaping | Chapter 17.44 (Landscaping) Parking | Chapter 17.46 (Parking and Loading) Signs | Chapter 17.48 (Signs) Other applicable standards | Chapter 17.40 (General Property Development and Use Standards) Notes: (1) See Chapter 17.43 regarding density bonus provisions. (2) Not more than 35 percent of the area between a street property line and a front building line may be paved. Unpaved areas must be planted and maintained with landscaping. Asphalt shall not be uses as a paving material. (3) Recessed pedestrian entries may be provided for a distance of 30 percent of the street frontage provided that the minimum length of the building frontage that is five feet from the street property line is not reduced to less than 25 feet. (4) Except as provided under the driveway provision of this section and the parking provisions of Chapter 17.46, paving shall be provided throughout the corner and front yards. Asphalt shall not be used as a paving material. (5) For properties having a rear property line abutting the side yard of a residential use, a minimum rear yard of seven feet shall be provided. For properties having a rear property line abutting an alley, a minimum rear yard of four feet shall be provided. (6) A 20-foot setback is required when abutting the rear yard of a residential use. (7) A 15-foot setback is required when adjacent to an R district. (8) Along the north side of Washington Boulevard west of Prime Court, and along the south side of Washington Boulevard west of Hudson Avenue, the maximum building height is 25 feet for non-residential and 37 feet for mixed-use projects. (9) Minimum building height is 15 feet.

(Ord. 7160 § 22, 2009; Ord. 7129 § 3 (Exh. B) (part), 2008)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.