Pretreatment standards for existing sources.
40 C.F.R. § 466.34
in effect(a) Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources.
Subpart C—PSES
Pollutant or pollutant property
Maximum for any 1 day
Maximum for monthly average
Milligrams per liter (mg/l)
Chromium0.420.17
Lead0.150.13
Nickel1.411.00
Zinc1.330.56
(b) In cases where POTW find it necessary to impose mass pretreatment standards the following equivalent mass standards are provided:
Subpart C—PSES
Pollutant or pollutant property
Maximum for any 1 day
Maximum for monthly average
Metal preparation
Coating operation
Metal preparation
Coating operation
Metric units—mg/m
2 of area processed or coated
Chromium16.340.536.620.22
Lead5.840.195.060.16
Nickel54.851.7838.91.26
Zinc51.741.6821.791.71
English units—pounds per 1 million ft
2 of area processed or coated
Chromium3.350.111.360.05
Lead1.200.041.040.03
Nickel11.240.377.970.25
Zinc10.60.354.460.35