For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.2.06 — Building Height Measurements and Exceptions

Code of the City of Grand Rapids, Michigan (Supp. No. 70: codified through Ordinance No. 2026-08, enacted April 14, 2026) · Grand Rapids City Code § 5.2.06

Corpus is an independent public-information project, not the official City of Grand Rapids website. Stable reference: corpuslaw.us/code/59bb4a3c-b4ec-4cb4-9d99-b085a24f2760

Sec. 5.2.06. - Building Height Measurements and Exceptions.

A. Measurement. 1. Stories. Where specified in stories, building height shall be measured in the number of stories entirely above the finished grade for any elevation fronting on a public street, including habitable attics, half-stories, and at-grade structured parking. a. Unless otherwise specified, story height is measured in feet between the floors of a story to the floor of the story above it. b. For the uppermost story, story height shall be measured from the floor of the story to the eave line on pitched roofs and to the tallest point of the roof deck on parapet and flat roofs. c. A mezzanine level counts as a story. d. For the purposes of this Chapter, the usable floor area of a half story is only that area having at least four (4) feet clear height between floor and ceiling. e. Unless otherwise specified, one (1) story shall be measured as not less than nine (9) feet nor more than fifteen (15) feet. The following shall be excluded: i. Spaces completely below the finished grade, such as basements, cellars, crawl spaces, sub-basements, and underground parking structures; and ii. A story shall not be counted as a story when more than fifty (50) percent of its cubic content is below the finished grade of the adjoining ground. [image omitted; see the official code] 5.2.07. Building Height (Measurement). 2. Height. When measured in feet, building height shall be measured as the vertical distance from the finished grade adjacent to the structure to the highest point of a flat roof; to the deck line of a mansard roof; and to the average height between the eave and ridge of the highest roof section for a gable, hip or gambrel roof. 3. Average Grade. See Section 5.16.02.G. for definitions of grade. When the terrain is sloping, the finished grade shall be the average of the elevation of the ground for each side of the structure, as measured six (6) feet from the exterior walls of the structure. B. Exceptions. The height requirements of all Zone Districts shall be subject to the following exceptions: parapet walls not exceeding four (4) feet in height, chimneys, cooling towers, elevator bulkheads, fire towers, gas tanks, utility penthouses, stacks, stage towers or scenery lofts, monuments, cupolas, domes and spires and necessary mechanical appurtenances. C. Airport Zoning Act. Proposed buildings or structures or modification to existing buildings or structures with a height greater than one hundred (100) feet require a permit from the Kent County Department of Aeronautics, pursuant to the Airport Zoning Act, Public Act No. 23 of 1950.

Ask a question about Grand Rapids law

Corpus searches the Grand Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.