Sec. 37-30.180. - Design standards.
(a) Purpose. These design standards are intended to assist the designer in understanding the city's requirements for high quality multifamily and higher density residential development. These standards complement the development regulations contained in this division by providing good examples of potential design solutions and by providing design interpretations of the various regulations. The designer shall also refer to the R-L district design standards, as many of the same architectural and design principles shall be applicable to higher density developments. These standards ensure the highest level of design quality while at the same time providing the flexibility necessary to encourage creativity on the part of project designers. The standards are also intended to promote higher density development that is pedestrian-oriented, safe, and reflects traditional neighborhood design principles.
(b) Site Planning.
(1) Multifamily housing, because of its higher densities, tends to generate large parking areas. If not properly designed, parking facilities can dominate the site and open spaces may be relegated to leftover areas, not related to the structures or the people who live there.
(2) Multifamily developments with dwelling units that face the street are highly encouraged. Developments that are surrounded by parking lots and rows of carports are examples of practices to be avoided. Instead, multifamily developments that have dwelling units that are oriented to the street, with covered architectural entry features or front porches that provide direct access to the street, and parking areas that are located to the rear of the dwelling units are desirable. Such site planning and design promotes neighborhood interaction, provides "eyes on the street," and ensures a more pedestrian-friendly streetscape.
(3) Clustering of multifamily dwelling units should be a consistent site planning element. Structures composed of a series of simple yet varied planes assure compatibility and variety in overall building form. This can be accomplished through the use of design techniques such as:
(A) Varying front setbacks within the same structure;
(B) Staggered and jogged dwelling unit planes;
(C) Using reverse building plans to add variety;
(D) A maximum of two adjacent dwelling units with identical wall and rooflines; and
(E) Using a variety of orientations to avoid the monotony of garage door corridors.
(4) Natural Surveillance. Whenever feasible, design and placement of residential dwellings and other physical features are encouraged to maximize visibility and facilitate natural surveillance from public rights-of-way and other public areas. This includes building orientation, placement of windows, doors, and balconies, building and site entrances and exits, placement and type of landscape materials, types of walls and fences (including the use of picket, wrought-iron, and similar materials to promote visibility when appropriate), and other physical obstructions in a manner that discourages the potential for criminal activity.
(d) Architecture. There is no particular architectural style required for multifamily residential structures. The primary focus shall be on constructing a high quality residential environment. The criteria presented here strives for this "quality" through descriptions and examples of appropriate building materials and architectural expression:
(1) In general, the design of multifamily developments shall consider compatibility with the surrounding neighborhood. The design should ensure that the height and bulk of higher density projects do not adversely impact or overwhelm lower density residential areas.
(2) Multifamily developments shall utilize a unifying theme and a consistent use of architectural elements and forms.
(3) Architectural styles that incorporate three-dimensional features such as porches, balconies, bay windows, dormers, and similar features shall be used to break up large wall and roof surfaces and create visual interest. The "barrack or motel" look shall be avoided.
(4) All elevations of the residential structures visible from streets and common open space areas in the project shall be architecturally treated.
(e) Mass and Scale. Because multifamily projects are usually taller than one story, their bulk can impose on surrounding uses. The scale of such projects shall be considered within the context of their surroundings. Large projects should be broken up into groups of structures. The use of single "mega-structures" shall be avoided in favor of structures that have a "human" scale.
(f) Materials. Materials selected for multifamily projects shall be very durable and require low maintenance. Piecemeal embellishment and frequent changes in materials shall be avoided. A palette of materials that convey an image of quality and durability shall be used. Painted surfaces shall reinforce and be compatible with the architectural style of the buildings.
(g) Facade and Roof Articulation. Long, unbroken facades and box-like forms shall be avoided. Building facades shall be broken up to give the appearance of a collection of smaller structures. To the extent possible, each of the dwelling units shall be individually recognizable. Separations, changes in plane and height, and the inclusion of elements such as balconies, porches, arcades, dormers, and cross gables, and the pattern and rhythm of windows and doors help mitigate the barrack-like appearance of flat walls and roofs of excessive length. Secondary hipped or gabled roofs covering the entire mass of a building are preferable to mansard roofs or segments of pitched roof applied at the structure's edge. Structures should incorporate at least one of the following:
(1) For each dwelling unit, at least one architectural projection not less than two feet from the wall plane and not less than four feet wide shall be provided. Such projections shall extend the full height of single story structures, at least half the height of a two-story building, and two-thirds the height of a three-story building; or
(2) A change in wall plane of at least three feet in depth for each two dwelling units shall be provided.
[image omitted; see the official code]
[image omitted; see the official code]
(h) Colors.
(1) Exterior building and roofing colors shall be appropriate to and enhance the architectural style and materials of the structure. Large areas of intense primary color shall generally be avoided as the dominant overall color for a structure.
(2) Primary or bold colors may only be used to accent architectural elements, such as door and window frames, trim, and similar features.
(3) Minimize the number of colors that appear on the structure's exterior. Smaller residential structures shall generally use no more than three colors unless appropriate to the architectural style.
(4) Roof flashing, rain gutters, and downspouts, vents, and other roof protrusions shall be finished to complement the adjacent materials and/or colors.
(i) Project Entries. Project entry areas provide the resident and visitor with an overview to the project and create a positive identity for the development. They should provide an open window with landscaping, open space areas, and project directories. Special attention should be given to hardscape and landscape treatments to enhance the overall project image.
(j) Parking.
(1) Parking Lots and Drives.
(A) In multifamily projects, large, monotonous, and undivided parking lots shall not be permitted. Parking areas shall be located to the rear of residential structures or within the interior of the development to reduce their visual impact on the streetscape. When environmental considerations or site constraints preclude such parking locations, dispersed parking courts located to the side of the dwelling units are the desired alternative. In such case, the parking courts shall be screened from view of adjacent streets by a landscape planter and shall not be located closer to the street than the street facade building line of the principal residential structure.
(B) Parking driveways, when located along the frontage of a site, isolate the development from its surroundings. Such driveways shall be avoided.
(C) Parking areas shall be conveniently located to the dwelling units that use them.
(D) Parking areas are encouraged to provide facilities for vehicles with alternative fueling systems (such as electric vehicle charging areas, etc.).
(E) The principal vehicular access into a multifamily housing project shall be through an entry drive rather than a parking lot driveway whenever feasible. Colored, textured paving treatment at entry drives is required at a minimum depth of ten feet located immediately behind the street property line. When separate exit drives are provided a matching treatment shall be required. Landscaping and site design should frame and distinguish entry and exit drives.
(2) Parking Courts.
(A) A parking court of any length shall not consist of more than two double-loaded parking aisles (bays) adjacent to each other.
(B) The length of a parking court shall generally not exceed fourteen parking spaces.
(C) Parking courts shall be separated from each other by dwelling units or by a landscaped buffer not less than thirty feet wide.
[image omitted; see the official code]
(3) Garages.
(A) Individual parking garages within residential structures shall be enclosed behind garage doors.
(B) Garages with parking aprons less than twenty-three feet in length shall have automatic garage door openers and sectional roll-up doors.
(C) Rowhouse dwellings that front public streets shall have garages accessible from alleys/driveways located at the rear of the project.
(D) Garages in multifamily developments shall be accessible only from the interior of a development and shall be oriented to not face public streets.
(4) Carports. Where carports are permitted, they must follow the same criteria for spatial arrangement as parking courts. Carports may be incorporated with patio walls or used to define public and private open space, but incorporating carports into exterior project walls adjacent to streets is prohibited. The ends of each cluster of carports shall be landscaped if visible from public or private streets, alleys, or adjacent properties. No more than an average of ten covered spaces of uninterrupted parking shall generally be permitted.
(5) Pedestrian Access from Parking. Landscape bulbs shall, wherever possible, align with major building entrances to provide pedestrian access to the building entrance from a parking court or drive. Bulbs that align with entrances should be at least two car spaces wide and should include a pathway as well as a vertical landscape or architectural element such as a trellis or a tree.
[image omitted; see the official code]
(k) Usable Open Space.
(1) Residents of housing projects shall have safe and efficient access to usable open space, whether public or private, for recreation, and social activities. The design and orientation of these areas should take advantage of available sunlight and be sheltered from the wind, noise, and traffic on adjacent streets, and incompatible uses.
(2) Required common open spaces shall be conveniently and centrally located to the majority of dwelling units in the development to promote a sense of community. Open space areas located within center courtyards is encouraged to provide resident privacy and security.
(3) Common usable open spaces and children's play areas shall be visible from individual dwelling units and be connected to the internal pedestrian system in the development.
(4) Private usable open spaces shall be contiguous to and have direct pedestrian access from the dwelling units they serve.
(5) All usable open space areas shall have appropriate lighting and be regularly maintained to reduce the potential for criminal activities.
(l) Landscaping. All areas not covered by structures, drives, parking, or hardscape shall be appropriately landscaped and maintained. Landscaping is used to frame, soften, and embellish the quality of the environment, to buffer dwelling units from undesirable views, and to break up large expanses of parking. To accomplish these design objectives, landscape elements need vertical dimension. Trees and tall shrubs are needed in addition to grass, small shrubs, and groundcover. Trees can also be used to provide shading and climatic cooling of nearby dwelling units and moderate prevailing winds.
(m) Recycling and Solid Waste Disposal. Recycling and solid waste disposal areas must be fully enclosed by masonry walls and solid gates, and such facilities shall meet the service needs of the city's solid waste operator. These enclosures shall be softened with landscaping on their most visible sides when practical. Recommended locations include inside parking courts or at the end of parking bays. Locations shall be conveniently accessible for trash collection, maintenance, and pedestrians (a separate walk-in access shall be provided), shall minimize solid waste vehicle driveway length into the property, and shall not block access drives during loading operations.
[image omitted; see the official code]
(n) Security. Multifamily projects shall be designed to provide the appropriate amount of security for residents and visitors. Parking and other site amenities shall be appropriately lit and located so as to be visible from dwelling units. Landscaping and dwelling unit design, including window, door, and balcony/porch placement, shall be planned and maintained to provide views into places where people gather, including adjacent open space areas, on-site recreational facilities/tot lots, and streets and alleys.
(o) Dwelling Unit Access. The use of long, monotonous access balconies and corridors that provide access to five or more dwelling units shall be avoided. Instead, access points to dwelling units should be clustered in groups of four or less. To the extent possible, the entrances to individual dwelling units shall be plainly visible from nearby parking areas and/or streets, as applicable. The use of distinctive architectural elements and materials to denote individual entrances is required. Individual dwelling units located adjacent to a public street shall be generally oriented to the street and include an entry feature such as porch that provides direct access to the street.
(p) Exterior Stairs. When provided, simple, clean, bold projections of stairways are encouraged to complement the architectural massing and form of the multifamily structure. Stairways shall be of smooth stucco, plaster, or wood, with accent trim of complementary colors and railings appropriate to the architectural style of the residential structure. Thin-looking, open metal, prefabricated stairs are discouraged.
(q) Accessory Structures.
(1) Carports, detached garages, and other accessory structures shall be designed as an integral part of the architecture of projects. They shall be similar in materials, colors, and detail to the principal structure(s) of a development.
(2) Carports, garages, and other accessory structures shall have a consistent roof design and pitch with the principal residential structure.
(3) A carport's vertical support structure shall have sufficient mass to be visually as well as structurally harmonious with the roof structure. Thin-looking posts or poles shall be avoided.
(4) Where garages are provided, doors shall appear to be set into walls rather than flush with the exterior wall.
(r) Solar Panels. Solar panels shall generally be integrated into the roof design. Frames shall be colored to match roof colors. Natural aluminum finish is strongly discouraged. Any mechanical equipment shall be enclosed and completely screened from view.
(s) Mechanical and Utility Equipment. All mechanical equipment whether mounted on the roof or ground must be screened from view. Utility meters and equipment shall be placed in locations that are not exposed to view from the street or they must be suitably screened. All screening devices shall be compatible with the architecture and color of the adjacent structures.
[image omitted; see the official code]
(t) Infill Multifamily in Existing Neighborhoods. Efforts shall be made to integrate new multifamily projects into existing neighborhoods so that they are compatible with adjacent structures and fit within the context of the existing neighborhood.
(1) Site Design. New multifamily developments shall be designed to continue the on-site relationships of the original structure(s) and surrounding neighborhood.
(2) Front Yard Setbacks. Front yard setbacks for new multifamily developments shall be compatible with the setbacks of adjacent properties.
(3) Architectural Compatibility. New multifamily development in existing neighborhoods shall incorporate architectural characteristics and maintain the scale of existing structures on the property and surrounding development. For example: window and door detaining, facade decoration, materials, color, roof style and pitch, and porches.
(4) Neighborhood Privacy. To provide privacy for adjacent dwelling units, windows on the second and higher floors of buildings which directly face or abut dwelling units in lower density residential zones should be designed either as translucent, louvered, or utilize another solution to achieve privacy for the adjacent dwelling units.
[image omitted; see the official code]
(u) Nonresidential Facilities.
(1) Nonresidential facilities such as water well pumping stations and storage, and the like, shall be designed to be compatible with the character of the surrounding neighborhood. Landscaping, decorative walls, or other buffering techniques, as appropriate, shall be used to ensure such facilities blend with and do not adversely impact adjacent uses.
(2) Any buildings constructed in conjunction with such facilities shall be compatible with the materials, exterior colors, and any distinctive architectural characteristics found in the surrounding neighborhood.
(3) The operators/property owners of such facilities shall be required (as a condition of approval) to provide regular maintenance for the life of such facilities (e.g., regular watering and care of vegetation (including replacement of any dead plant material or broken irrigation apparatus), trash and graffiti removal, and the repair and replacement of any damaged or worn-out facilities).
(Ord. No. 2463 (NCS).) (Ord. No. 2507 (NCS), § 26, 5-18-2010)