9-14-25. - Cap Types.

The major components of any roof shall meet the requirements of one or a combination of the cap types permitted for the building type pursuant to the building types requirements of Sections 9-14-16 through 9-14-21, B.R.C. 1981. (a) Minor Roofs. Roofs for bay or bow windows, porches, canopies, and dormers are not required to meet the standards of a cap type. (b) Terraces, Green Roofs, Rooftop Gardens, and Other Outdoor Rooftop Facilities. Terraces, green roofs, rooftop gardens, and other outdoor facilities are allowed on any roof; however, the roof and any vertical elements of the outdoor facilities shall be consistent with the standards of a cap type. (c) Encroachments. Roofs, including all eaves or overhangs, shall be fully located within the property lines of the lot, but may encroach into yards consistent with the standards in Section 9-7-3, "Setback Encroachments," B.R.C. 1981. (d) Pitched Cap Type. The pitched cap type has a sloped or pitched roof. Slope is measured with the vertical rise divided by the horizontal span or run, as shown in Figure 14-46. Examples of Pitched Cap Type. (1) Pitch Measure. The roof shall not be sloped less than 4:12 (rise:run) or more than 14:12. Slopes less than 4:12 are permitted to occur on second story or higher roofs. (2) Configurations. (A) Gambrel, hipped, gabled, or a combination of hips and gables with or without dormers are permitted. (B) Butterfly (inverted gable roof) and shed roofs are permitted. (C) Mansard roofs are permitted, provided dormers meeting the transparency requirement of a story are incorporated into the roof design. (3) Parallel Ridge Line. A gabled end or perpendicular ridge line shall occur at least every 100 feet of the roof when the ridge line runs parallel to the front lot line. See Figure 14-46. Examples of Pitched Cap Type. (4) Roof Height. Roofs without occupied building space or dormers shall have a maximum height on Type A and Type B frontage facades equal to no more than 1.5 times the upper story floor-to-floor height used on the building. (5) Occupied Building Space. Occupied building space may be incorporated within the pitched cap type. If occupied, the space counts as a half story. (6) Rooftop Appurtenances. Any rooftop appurtenances shall be recessed within the pitched roof with no visibility when viewed from the sidewalk across the street and from any adjacent outdoor space. See Figure 14-47. Recessed Mechanicals in Pitched Cap Type. See Section 9-14-33, "Mechanical and Utility Elements," B.R.C. 1981, for additional requirements.

![Figure 14-46. Examples of Pitched Cap Type](https://figures.74-208-44-221.nip.io/boulder/496676/761a8e905bac6bfb9ae7073473bf373d76ead0d363abde76559c024fdbae3206.png)

Figure 14-46. Examples of Pitched Cap Type

![Figure 14-47. Recessed Mechanicals in Pitched Cap Type](https://figures.74-208-44-221.nip.io/boulder/496676/1bec288f3792caf68950925587517eb99736b6571d7ccc8593c0978edfe1f78a.png)

Figure 14-47. Recessed Mechanicals in Pitched Cap Type (e) Parapet Cap Type. A parapet is a low wall projecting above a building's roof along the perimeter of the building as shown in Figure 14-48. Example of a Parapet Cap Type. (1) Parapet Height. Parapet height is measured from the top of the upper story to the top of the parapet. (A) General Parapet Heights. Minimum parapet height is two feet with a maximum height of six feet. (B) Parapets Exceeding Maximum Height. The approving authority may approve a parapet causing the building height to exceed the maximum permitted height if the approving authority finds the standards for parapet walls of Section 9-7-7, B.R.C. 1981, are met. (2) Horizontal Expression Lines. An expression line that is at least two inches deep and extends along at least eighty percent of the facade shall define the parapet from the upper stories of the building and shall define the top of the cap. (3) Occupied Building Space. No building shall have occupied space behind a parapet cap. (4) Roof Terraces and Roof Decks. Roof terraces and roof decks are permitted on the parapet cap type. (5) Rooftop Appurtenances. Any rooftop appurtenances shall be located towards the rear or interior of the parapet roof. The parapet shall screen the mechanicals when viewed from the sidewalk across the street and from any adjacent outdoor space. See Section 9-14-33, "Mechanical Equipment & Appurtenances," B.R.C. 1981, for additional requirements.

![Figure 14-48. Example of a Parapet Cap Type](https://figures.74-208-44-221.nip.io/boulder/496676/d4e4c2e43f543142505e5b8ea5a713df3cbd2c41f820f7407162898b7d120978.png)

Figure 14-48. Example of a Parapet Cap Type (f) Flat Cap Type. The flat cap type has a visually flat roof with overhanging eaves as shown in Figure 14-49. Example of a Flat Cap Type. (1) Configuration. The roof shall have no visible slope from the street, and eaves are required on all Type A and Type B frontage facades. (2) Eave Depth. Eave depth is measured from the building facade to the outside edge of the eave. Eaves shall have a depth of at least fourteen inches. (3) Eave Thickness. Eaves shall be a minimum of six inches thick. Eave thickness is measured at the midpoint of the eave depth, from the bottom of the eave to the top of the eave. The measurement may be taken from a structural support element of the eave to the top of the eave, provided the structural support element occurs at least every four feet along the entire length of the eave. (4) Interrupting Vertical Walls. Vertical walls may interrupt the eave and extend above the top of the eave with no discernible cap if the following requirements are met: (A) No more than one-third of the front facade shall consist of an interrupting vertical wall. (B) Vertical walls shall extend no more than six feet above the top of the eave. See Figure 14-49. Example of a Flat Cap Type. (5) Occupied Building Space. No building shall have occupied space behind a flat cap. (6) Roof Terraces and Roof Decks. Roof terraces and roof decks are permitted on the flat cap type. (7) Rooftop Appurtenances. If the interrupting vertical wall is utilized, any rooftop appurtenances shall be located behind the vertical wall with no visibility when viewed from the sidewalk across the street and from any adjacent outdoor space. If no interrupting vertical wall is utilized, rooftop appurtenances shall be located such that the mechanicals are not visible when viewed from the sidewalk across the street or from any adjacent outdoor space. See Section 9-14-33, "Mechanical Equipment & Appurtenances," B.R.C. 1981, for additional requirements.

![Figure 14-49. Example of a Flat Cap Type](https://figures.74-208-44-221.nip.io/boulder/496676/e9cd50fc01b05c88ae0c418ae47b39270d1a9e51b45ffb572441bf51125ed82c.png)

Figure 14-49. Example of a Flat Cap Type (g) Towers. A tower is a vertical element, polygonal (simple), rectilinear, or cylindrical in plan that shall only be used with other cap types. See Figure 14-50. Example of a Tower. (1) Additional Height. Towers may add a single story of additional height beyond the maximum height allowed per building type, however, a tower may not exceed a maximum height of fifty-five feet. (2) Tower Width. The maximum tower width along all facades shall be one-third the width of the front facade or fifteen feet, whichever is less, and may not occupy more than 25% of the roof area. See Figure 14-50. Example of a Tower. (3) Transparency. Towers that meet the minimum floor-to-floor height of the building type shall meet the minimum transparency requirements of the building. (4) Horizontal Expression Lines. A minimum two inches deep expression line is required at the cap of the tower. (5) Occupied Building Space. Towers with minimum floor-to-floor heights required by the building type shall be occupied space and may contain any of the uses allowed in upper stories of the building type to which it is attached. (6) Rooftop Appurtenances. No rooftop appurtenances are permitted on tower roofs. (7) Tower Cap. The tower shall be capped by a cap permitted on the building per the building type.

![Figure 14-50. Example of a Tower](https://figures.74-208-44-221.nip.io/boulder/496676/95e84dd9be05e0ce43ccd2cf735a6262ac6a5a9d0eea3f7615af54f420263646.png)

Figure 14-50. Example of a Tower Ordinance No. 8669 (2025)