Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
40 C.F.R. § 411.12
in effectExcept as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic
Effluent limitations (maximum for any 1 day)
Metric units (kg/kkg of product)
TSS0.005.
Temperature (heat)Not to exceed 3 °C rise above inlet temperature.
pHWithin the range 6.0 to 9.0.
English units (lb/1,000 lb of product)
TSS0.005.
Temperature (heat)Not to exceed 3 °C rise above inlet temperature.
pHWithin the range 6.0 to 9.0.