Sec. 31-118. - IECC Amendments - Appendix CB (Commercial).
Only the following portion of APPENDIX CB SOLAR-READY ZONE of the IECC is amended. (a) Section CB103.1, General, is amended to read as follows: CB103.1 General. A solar-ready zone shall be located on the roof of buildings that are oriented between 110 degrees and 270 degrees of true north or have low-slope roofs. Solar-ready zones shall comply with Sections CB103.2 through CB103.9. Exceptions: 1. A building with a permanently installed, on-site renewable energy system. 2. A building with a solar-ready zone that is shaded for more than 70 percent of daylight hours annually. 3. A building where the licensed design professional certifies that the solar zone area required by Section CB103.3 cannot be met because of extensive rooftop equipment, skylights, vegetative roof areas or other obstructions.
(Ord. No. 4575, § 1(Res. No. 12503, § 1(Exh. A)), 12-6-22)