Sec. 17-72. - Discharging firearms.
(a) It shall be unlawful for any person to shoot or fire a gun or other firearm within the city except as follows:
(1) In the execution of the law.
(2) At a military parade by order of a proper officer.
(3) If the person holds a license, which license may be issued by the chief of police upon the application of an individual or organized gun or skeet club to discharge shotguns only upon specifically described premises within the city. Each application for such authority shall be submitted to the chief of police at least five days in advance of any requested shooting date and must be accompanied by a map or plat showing all roads and development within 300 yards of the property upon which the shooting is to be allowed. Any license issued by the chief of police to any individual or club under this subsection shall be limited as to the premises and shall be limited to such times as the chief of police may determine, not exceeding one year. The chief of police shall take into consideration, in granting or refusing such permits, the proximity of such premises to inhabited dwellings, businesses, streets or highways, and also the likelihood that persons or domestic animals will be endangered by such shooting.
(4) At a range, shooting gallery, or test site, for the discharge of specific types of firearms and ammunition, approved by the inspection division as meeting the design, operational and other requirements set forth as follows:
a. Location. Location shall be as set forth in the zoning ordinances for the city.
b. Codes. Building and construction shall comply with the following codes as adopted and amended by the city:
1. Standard Building Code.
2. National Electrical Code.
3. Standard Plumbing Code.
4. Standard Gas and Mechanical Codes.
5. Other ordinances as they may apply.
c. Miscellaneous building requirements. Notwithstanding all other provisions of this section:
1. Other uses within an indoor firing range building shall be separated from the firing range as required by the Standard Building Code.
2. Buildings classified as type V or VI construction by the Standard Building Code shall not be considered for use as an indoor firing range.
3. Walls, floors and ceilings of the firing range itself must be bulletproof for the type of firearms, bullet weight, velocity and bullet construction to be permitted. Bulletproof means the ability of the wall, floor and ceiling material to contain three maximum power projectiles fired into any point from behind the firing line, and as certified by an architect or engineer registered under the laws of the state.
4. Ricochet control within the firing range shall be by absorption and/or deflection and shall be explained by plans and specifications.
d. Plans and specifications. The permittee shall submit to the inspection division the following:
1. A complete set of building plans and specifications and other engineering reports as may be required as sealed by an architect or engineer legally registered under the laws of the state, the plan to include plat, building specifications, parking availability, landscaping, outdoor advertisement signs, and types of firearms, bullet weight, velocity and bullet construction to be allowed.
2. A standard operating procedures manual, for file purposes only, which shall include, but not be limited to, the following:
i. Posting of warning or precautionary signs.
ii. Availability of hearing and eye protection.
iii. Firing range cleaning procedures and methods of disposing of waste.
iv. Procedures for removing lead from bullet trap.
v. Disposal of lead recovered from bullet trap.
vi. Disposal procedures for spent bullet trap material.
vii. Ventilation system testing procedures and schedules.
viii. Specifications of and maintenance schedules for air cleaning system (recirculation type only).
3. Proof of a public liability insurance policy with a minimum limit amount of $500,000.00 for the purpose of payment of all damages to persons or property which may arise from or be caused by the conduct of any act on the property, authorized by the city, upon which any legal judgment results.
e. Environmental.
1. Noise. All noises emanating from the property shall comply with chapter 12, article V, except that the sound of firearm discharge and the sound of bullet impact shall not exceed 65 percent of the levels established in those sections; and where a firing range property adjoins residentially zoned property, the sound of firearm discharge and the sound of bullet impact shall not be audible at or beyond the property line. Compliance with noise requirements shall be determined by personnel of the natural resources and environmental management divisions and reported to the manager of the inspection division for appropriate action. These noise restrictions apply only to adjoining property lines exterior to any building which houses a firing range.
2. Ventilation system.
i. Fresh air system. The exhaust system shall be so designed that the air entering the range is from above and behind the firing line, is evenly distributed across all firing stations, and will result in an air velocity of between 65 and 85 feet per minute (fpm) past the firing line. At least 75 percent of the air volume shall be exhausted at the target/backstop area. The velocity shall be tested and certified every six months and results reported to the inspection division. Prior approval of the methodology for testing and certification must be given by the inspection division.
ii. Recirculation system. If a recirculation type ventilation system is utilized, the requirements stated in subsection (a)(4)e.2.i. of this section shall apply, and in addition, an air cleaning system (with pressure drop indicator) which will remove 99.97 percent of all particles greater than or equal to 0.3 micron in diameter must be installed and operated.
3. Wastewater. If the range area is to be cleaned by flushing with water, the floor drain shall be equipped with a grit trap and other control devices as required and approved by the natural resources and environmental management division.
4. Inspection. The range shall be subject to periodic inspection by the natural resources and environmental management division to determine compliance with noise and ventilation requirements. Results of such inspections shall be reported to the inspection division for appropriate action.
5. Testing. Before a certificate of occupancy is issued, the range shall be tested for the requirements contained within this section. This testing shall be accomplished by an agency approved by the inspection division. All costs associated with such testing shall be paid by the owner. Results of a test completed within the previous six months to validate compliance of the bulletproof and ventilation requirements shall accompany the application for an annual business license.
(b) Nothing contained in this section shall exempt compliance with all other applicable laws, ordinances or regulations.
(Code 1982, § 18-49; Ord. No. 84-835, 12-13-1984; Ord. No. 88-208, 5-26-1988; Ord. No. 89-109, 3-9-1989)