Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).
40 C.F.R. § 420.103
in effectExcept as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
(a) Cold rolling mills—(1) Recirculation—single stand.
Subpart J
Pollutant or pollutant property
BAT effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium
10.00002090.0000084
Lead0.00000940.0000031
Nickel
10.00001880.0000063
Zinc0.00000630.0000021
Naphthalene0.0000021Tetrachloroethylene0.0000031
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.
(2) Recirculation—multiple stands.
Subpart J
Pollutant or pollutant property
BAT effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium
10.0001040.0000418
Lead0.00004690.0000156
Nickel
10.00009390.0000313
Zinc0.00003130.0000104
Naphthalene0.0000104Tetrachloroethylene0.0000156
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.
(3) Combination.
Subpart J
Pollutant or pollutant property
BAT effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium
10.001250.000501
Lead0.0005630.000188
Nickel
10.001130.000376
Zinc0.0003760.000125
Naphthalene0.000125Tetrachloroethylene0.000188
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are cotreated with descaling or combination acid pickling wastewaters.
(4) Direct application—single stand.
Subpart J
Pollutant or pollutant property
BAT effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium
10.0003760.000150
Lead0.0001690.0000563
Nickel
10.0003380.000113
Zinc0.0001130.0000376
Naphthalene0.0000376Tetrachloroethylene0.0000563
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.
(5) Direct application—multiple stands.
Subpart J
Pollutant or pollutant property
BAT effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium
10.001670.000668
Lead0.0007510.000250
Nickel
10.001500.000501
Zinc0.0005010.000167
Naphthalene0.000167Tetrachloroethylene0.000250
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.
(b) Cold worked pipe and tube—(1) Using water.
Subpart J
Pollutant or pollutant property
BAT effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium
10.00002090.0000084
Lead0.00000940.0000031
Nickel
10.00001880.0000063
Zinc0.00000630.0000021
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters.
(2) Using oil solutions.
Subpart J
Pollutant or pollutant property
BAT effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
Chromium
10.00002090.0000084
Lead0.00000940.0000031
Nickel
10.00001880.0000063
Zinc0.00000630.0000021
Naphthalene0.0000021Tetrachloroethylene0.0000031
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters.