For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15-1611 — NEIGHBORHOOD REVITALIZATION (NR) OVERLAY DISTRICT

Fresno Municipal Code (Supp. No. 55, Update 1 (online June 23, 2026): codified through Ordinance No. 2026-019) · Fresno Municipal Code § 15-1611

Corpus is an independent public-information project, not the official City of Fresno website. Stable reference: corpuslaw.us/code/5df70fdb-ca4d-4f40-a542-00f3c9e215c2

SEC. 15-1611. - NEIGHBORHOOD REVITALIZATION (NR) OVERLAY DISTRICT.

A. Purpose. The Neighborhood Revitalization (NR) Overlay District is intended to preserve the unique character of neighborhoods near Downtown, enhance their walkability, and promote a diverse population. B. Use Regulations. Those uses permitted and conditionally permitted in the Base District, subject to the limitations and conditions set forth therein, with the following exceptions. 1. Duplex—a neighborhood meeting shall not be required. 2. Multi-Unit Residential at a density of 16 dwelling units per acre or less. A neighborhood meeting shall not be required. 3. Instructional Services which are 3,000 square feet or less and which occupy 30 percent of the building or less. 4. Parks and Recreation Facilities shall not be subject to any size restriction of the Base District. 5. Medical and Dental Offices, which are 3,000 square feet or less and which occupy 30 percent of the building or less shall be permitted. 6. General Retail, which is located within 100 feet of a corner and which is 3,000 square feet in area or less shall be permitted. C. Development Standards. Development Standards shall be as required by the Base District, except as follows: 1. Sidewalks. a. Sidewalks shall be provided on both sides of the street. Notwithstanding Chapter 13, Section 208 of the Municipal Code, all projects shall be required to bring adjacent sidewalk conditions into conformance with Public Works standards, subject to the following exceptions: i. Applications for signs only. ii. Additions, remodels, or tenant improvements of less than 50 percent of the current value of the property. iii. Accessory structures less than 1,000 square feet in size. b. New development that is below the thresholds noted in item 'a', above, shall replace and maintain missing and/or dead street trees and any other missing or dead landscaping in the public frontage (public right-of-way). c. In no case shall an existing sidewalk, or portion thereof, be vacated, even if the minimum width required is less than the existing sidewalk. d. When a sidewalk of the subject property is improved to meet the applicable requirements of this section and the adjacent property does not physically align with the new improvement, the improvement shall be designed to the satisfaction of the Review Authority to result in a safe and smooth transition between properties. 2. Pedestrian Access. Direct entrances shall be provided into all individual ground-floor dwelling units or commercial spaces which are adjacent to a public street. If the building is set back from the sidewalk, a paved path no less than five feet in width shall be provided from the sidewalk to each entrance. 3. Front Setback. The front setback for new structures shall not be greater than 110 percent nor less than 90 percent of the average of the actual front setbacks of all residential structures on the blockface which were constructed prior to 1945. The following exceptions shall apply: a. In no instance shall the front setback be less than 10 feet. b. In no instance shall the setback for a new structure be less than the setback of an adjacent structure which is a designated historic resource. 4. Parking. In no instance shall parking be located in front of the primary building, between the primary building and the street, or within the required front setback. Surface parking may not be covered with a carport within 50 feet of a public street unless it is designed as a porte cochere that is attached to architecturally integrated with the residential structure. 5. Building Size and Massing. Table 15-1611-C.1 prescribes additional development standards for areas governed by the NR Overlay District. Additional regulations are denoted in the right hand column. Section numbers in this column refer to other sections of the Code, while individual letters refer to subsections that directly follow the table. The numbers in each illustration below correspond to the "#" column in the associated table. Drawings are for illustrative purposes and are not drawn to scale. TABLE 15-1611-C.1: BUILDING SIZE AND MASSING STANDARDS [image omitted; see the official code] District | RS-3 | RS-5 | # Maximum Building Length along Primary Street (ft.) | 60 | 60 | ① Maximum Space between buildings along Primary Street (ft.) | 15 | 10 | ② Maximum Building Depth along Street Side (ft.) | 60 | 120 | ③ 6. Building Articulation. a. Street-Facing Façade Articulation. All street-facing building façades over 35 feet in length shall be designed with a minimum of one of the following façade articulation strategies: i. Horizontal Articulation. Setback a portion of the street-facing facade a minimum of two feet for a minimum distance of 25 feet. ii. Vertical Articulation. Step a portion of the façade upward or downward a minimum two feet higher or lower than adjacent portions of the façade for a minimum distance of 25 feet. iii. Architectural Projections. Append or project facade elements such as porches, balconies, bay windows, cantilevered rooms, and/or awnings. iv. Architectural Recessions. Recess architectural elements or spaces—such as recessed porches, covered passages, recessed balconies, and windows—into the plane of the façade. b. Roof Forms. New structures shall have roof forms which are residential in character, such as gabled, hipped, mansard, gambrel, and pyramidal roofs. 7. Building Materials and Finishes. a. General Standards. i. Each side of a building that is visible from a street, park, or passenger railway shall be designed with a complementary level of detailing and quality of materials. ii. Building Entrances and Common Areas. Building entrances and common areas shall include finishes and materials that are durable and high quality and distinguish these spaces from other elements of the building. iii. Parking. Parking structures shall be designed to be compatible with the architectural character, materials, and colors of the overall development. iv. Durability of Materials. Exterior materials shall be durable and promote permanence and longevity. They shall not unintentionally discolor due to weathering or corrosion. Materials that discolor naturally, such as copper, are encouraged. v. Design Consistency. (1) Architectural materials and constructional assemblies shall be designed to be consistent with the building's architectural style in terms of structural expression, scale, and proportion. (2) Finishes, fixtures, and other architectural details shall be designed to be consistent throughout the building's exterior. (3) Attached architectural elements and details such as lighting fixtures, attic vents, custom signage, awnings, hand rails, balconies, and trellises shall be designed to be consistent with other elements throughout the building's exterior. b. Multiple Materials. i. Two or more wall materials may be combined on one façade. ii. If located one above the other, lighter appearing materials shall be placed above more substantial materials (e.g., wood above stucco or masonry, or stucco and glass above masonry). iii. In general, vertical joints between different materials shall occur only at inside corners. c. Exposed Wood. i. Exterior walls that are or were originally clad in exposed wood shall not be covered with a non-wood material. Wood-like materials, such as cementitious siding, may be used. ii. Exposed wood (or wood-like materials) shall be finished in a manner that minimizes maintenance and promotes the material's longevity. d. Reflective Materials. Reflective materials are prohibited. e. Masonry and Stone. i. Brick and cut stone shall be laid in true bonding patterns. Mortar joints shall be struck. ii. River and rubble stone shall be laid from large stones closest to the ground to small stones farthest from the ground, with smooth or beaded mortar joints. iii. Masonry detailing shall transition from stone to other materials through moldings, caps, and other trim elements. f. Veneers. Veneers should turn corners, avoiding exposed edges and continue down the side of a building to a logical break, such as a change in wall plane. g. Trim. Trim materials and finishes shall be differentiated from adjacent wall cladding materials and finishes. Acceptable trim materials shall be wood, precast concrete, stone, tile, or similar materials. Stucco trim shall be permitted at the discretion of the Review Authority, and in such instances it shall feature a smooth finish that contrasts significantly from adjacent stucco wall cladding. h. Synthetic Materials. The use of synthetic materials is allowed when the Review Authority determines that the material: i. Adequately simulates the appearance of the natural material it imitates. ii. Demonstrates an ability to age similar to or better than the natural material it imitates. iii. Has a permanent texture, color, and character that is acceptable for the proposed application. iv. Can be pressure washed and, in general, withstand anti-graffiti measures. i. Prohibited Materials. Prohibited exterior materials include the following: i. T1-11. ii. Rough-sawn wood. iii. Vertical siding, except board and batten. iv. Metal siding. v. Concrete block as an exterior finish material. j. Renovations and Alterations. i. Modifications to existing buildings shall be architecturally compatible with the existing building as determined by the Review Authority. ii. Exterior walls that are or were originally clad in wood, masonry, or stone shall not be covered with a different material such as stucco. iii. Renovations or alterations to "modernized" pre-World War II buildings shall restore the original façade materials, textures, fenestration, and ornamentation to the extent possible as determined by the Review Authority. 8. Window and Door Opening Design. a. Window Hierarchy. Building elevations shall exhibit a hierarchy between window sizes to differentiate between public rooms (larger windows) and private rooms (smaller windows). b. Glazing Ratio. Street-facing facades, shall have an overall wall composition of at least 20 percent glazing, but not more than 60 percent glazing. c. Vertical Proportion. 75 percent or more of window openings shall have a vertical proportion, in which their height exceeds their width by 25 percent or more. Openings divided by muntins of four inches or more in width shall constitute separate openings. d. Window Depth. Trim at least three-quarters inch in depth must be provided around all windows, or windows must be recessed at least two inches from the plane of the surrounding exterior wall. For double-hung and horizontal sliding windows, at least one sash shall achieve the two-inch recess. The recess depth shall be specific to the architectural style being utilized. e. Relationship to Surrounding Buildings. Windows shall be placed on a wall in a manner that maintains existing privacy with neighbors. f. Window and Door Materials and Detailing. i. Allowed window and door materials include wood, fiberglass, steel, or aluminum. ii. Muntins, if used, shall be true and divide one pane from the adjoining pane, be of substantial dimension, and not be flat. iii. Flush "nail-on" aluminum windows, and horizontal aluminum sliding windows are prohibited. iv. The color of vinyl and vinyl clad windows shall be consistent with the overall color scheme of the building. For example, white windows should be used with window trim that is painted a deep color. v. Glazing shall be clear glass, particularly in storefront and primary window applications. Transom and other specialty windows are not required to be clear and may be decorative. vi. Window sills shall be detailed to properly shed water. vii. Head casing shall be equal in width to or wider than jamb casing. viii. Accessories may include operable shutters sized to match their openings, opaque canvas awnings and other shading devices, and planter boxes supported by visible brackets appropriate to each design. Security bars are prohibited on façade windows. 9. Façade Alignment. a. Vertical Alignment. With the exception of roofs, cornices, and other such features, façades shall be oriented vertically and shall have no slope. b. Horizontal Alignment. With the exception of bay windows and similar features, facades that are located within 30 feet of a public street shall run parallel or perpendicular to said street. Civic buildings are exempt from this requirement. 10. Façade Elements. a. Applicability. Street-facing façades shall incorporate a minimum of two of the Façade Elements shown in Table 15-1611-C.6. TABLE 15-1611-C.6: FAÇADE ELEMENTS—NR OVERLAY DISTRICT A. Front Yard 1. Basic Standards | [image omitted; see the official code] ⓐ Clear Depth: 5 ft. min. ⓑ Length: 15 ft. min. ⓒ Height above Sidewalk: 3 ft. max. 2. Supplemental Standards a. Planters, garden walls, fences and hedges are permitted at the sidewalk to a maximum height of 3 ft. per Section 15-2006. Materials and design shall be compatible with the architectural style of the building. b. Water features, shade structures, seating, and gardens are encouraged in this area. c. Vehicular parking, trash collection, and storage are not permitted in this area. d. When Front Yards are raised from the level of the sidewalk, the resulting retaining wall shall be decorative and clad in brick or stone. B. Porch 1. Basic Standards | [image omitted; see the official code] ⓐ Clear Depth: 5 ft. min., 15 ft. max. ⓑ Length: 8 ft. min. ⓒ Height above adjacent grade: 18 in. min., 4 ft. max. ⓓ Height: 8 ft. min. clear from the finish floor 2. Supplemental Standards a. Provide landscaping in front of and around porch. b. Railings should be no higher than required by the building code. c. The porch may extend around to encroach into the street sideyard up to ½ of the required setback. If insufficient distance exists, the minimum porch depth shall be achieved by moving back the façade the necessary distance. d. Awnings may be attached to the face of the porch if the awning is adequately supported and if the awning is compatible with the architectural style of the porch and building. e. Porches shall not be enclosed, including by insect screens. C. Stoop 1. Basic Standards | [image omitted; see the official code] ⓐ Clear Depth: 6 ft. min., 15 ft. max. ⓐ Length: 4 ft. min., 10 ft. max. ⓐ Height: Max. 4 ft. elevation above finish sidewalk grade 2. Supplemental Standards a. Landscaping encouraged in front, around and/or within walls of stoop. b. Minimum 3 ft. to maximum 4 ft. high garden wall and gate may be provided at entry to stoop. c. Entry gates to swing in a direction away from sidewalk. d. Use of other frontage types at entry stoop (e.g., awning, bay window, arcade) allowed. e. Exterior stairs may be located perpendicular or parallel to the adjacent sidewalk. f. The landing may be covered or uncovered, but shall not be enclosed beyond the building façade (e.g., stoop landings may be recessed into the building façade and be enclosed by the walls of the recess. D. Terrace 1. Basic Standards | [image omitted; see the official code] ⓐ Clear Depth: 7 ft. min. ⓑ Length: no min./no max. ⓒ Height: Max. 4 ft. elevation above finish sidewalk grade ⓓ Railing Height: no higher than required by the building code 2. Supplemental Standards a. Use of other frontage types (e.g., awning, bay window) allowed. b. Exterior stairs may be perpendicular or parallel to the adjacent sidewalk but shall not encroach into the right-of-way. The landing may be covered or uncovered. E. Bay Window 1. Basic Standards | [image omitted; see the official code] ⓐ Depth: 2 ft. min., 4 ft. max. ⓑ Length: 15 ft. max. ⓒ Height for 2nd fl.: 10 ft. min. clear from the ground ⓓ Encroachment into Setback.: 3 ft. max. 2. Supplemental Standards a. Bay windows are permitted on the ground floor of buildings with residential ground floors. b. Provide landscape in front and around bay windows on the ground floor. c. Bay windows to have a minimum 25% glazing. F. Balcony 1. Basic Standards | [image omitted; see the official code] ⓐ Depth: 5 ft. min., 10 ft. max. ⓑ Length: 8 ft. min. ⓒ Height: 8 ft. min. clear, 12 ft. max. clear from the finish floor ⓓ Encroachment into Setback: 4 ft. max. 2. Supplemental Standards a. Balcony may be covered but should be a minimum 50% open on three sides.

(Am. Ord. 2016-43, § 5, eff. 12-9-16).

Ask a question about Fresno law

Corpus searches the Fresno sections it holds and shows the ones that match, with their citations. Free, no sign-in.