Sec. 30-80. - General requirements for storm sewers.

The capacity of all storm sewers shall be determined by using a rational approach, giving due consideration to rainfall intensity, soil characteristics, proper runoff coefficients, slope, and the hydraulic properties of the pipes used. Interceptors should be placed at intervals not to exceed six hundred (600) liner-feet, except under special conditions as approved by the department of planning and development and in matters of construction of public projects contracted with or performed by public works, the public works department. The designed rainfall intensity shall be based on four (4) inches per hour except in new subdivisions, where the rainfall intensity shall be based on a time of concentration of at least a once in ten-year expectancy as determined from local rainfall records. The minimum design velocity shall not be less than two and one-half (2½) feet per second. The maximum design velocity shall not exceed ten (10) feet per second.

(Code 1961, § 36-12(d); Ord. No. 21,867, § 1, 5-19-20)