§ 3-88.6. - Fire Prevention Permit types and fees.
A. Permit types. In addition to the registration of life hazard uses, certain activities and uses are required to be regulated by permits. Permits are classified into six types with a permit fee for each type levied on an annual basis. Those seeking to obtain a permit must pay the required fee to the Bureau of Fire Prevention which is empowered to monitor these activities and conduct periodic inspections. Type 1 Permit: The following activities require a Type 1 Permit: Bonfires; The use of a torch or flame-producing device(s) to remove paint from, or seal membrane roof on, any building or structures; Individual portable kiosks or displays when erected in a covered mall for a period of less than 90 days, and when not covered by a type 2 permit; The use of any open flame or flame producing device(s) in connection with any public gathering, for purposes of entertainment, amusement, or recreation in places of public assembly; The possession or use of explosives or blasting agents; The use of any open flames or flame-producing device in connection with the training of non-fire service personnel in fire suppression or extinguishment procedures; The occasional use in any building of a multipurpose room, with a maximum permitted occupancy of 100 or more for amusement, entertainment or mercantile type purposes; The storage or handling of Class I flammable liquids in closed containers of aggregate amounts of more than ten gallons, but not more than 660 gallons inside a building, or more than 60 gallons, but not more than 660 gallons outside a building; The storage or handling of Class II or IIIA combustible: liquids in closed containers of aggregate amounts of more than 25 gallons, but not more than 660 gallons inside a building, or more than 60 gallons, but not more than 660 gallons outside a building; Any permanent cooking operation that requires a suppression system in accordance with N.J.A.C. 5:70-4.7(g) and is not defined as life hazard use in accordance with N.J.A.C. 5:70-2.4; The use as a place of public assembly, for a total of not more than 15 days in a calendar year, of a building classified as a commercial farm building under the Uniform Construction Code. Helicopter landings. Type 1A Permit. The following activities require a type 1A permit: Mobile food vendors utilizing combustible fuels, i.e. propane. Type 2 Permit. The following activities require a type 2 permit: Bowling lane resurfacing and bowling pin refinishing involving the use and application of flammable liquids or materials; Carnivals and circuses employing mobile structure used for human occupancy; The use of a covered mall in any of the following manners: To placing or construct temporary kiosks display booths, concession equipment, or the like in more than 25 percent of the common area of the mall; As a place of assembly; Any use which involves open flames or flaming devices; Any use which involves the use or display of liquid or gas-fueled powered equipment; or Any use which involves using liquefied petroleum gas, liquefied natural gas, and compressed flammable gas in containers exceeding five lbs. capacity. Type 3 Permit. The following activities require a type 3 permit: Industrial processing ovens or furnaces operating at approximately atmospheric pressures and temperatures not exceeding 1,400 degrees Fahrenheit which are heated with oil or gas fuel or which contain flammable vapors from the products being processed; Any wrecking yard or junkyard; or The storage or discharging of fireworks. Type 4 Permit. The following activities require a type 4 permit: Storage or use at normal temperature and pressure of more than 2,000 cubic feet of flammable compressed gas or 6,000 cubic feet of non-flammable compressed gas; The production or sale of cryogenic liquids; the storage or use of more than ten gallons of liquid oxygen, flammable cryogenic liquids or cryogenic oxidizers; or the storage of more than 500 gallons of non-flammable, non-toxic cryogenic liquids; The storage, handling, and processing of flammable, combustible and unstable liquids in containers and portable tanks as in aggregate amounts of more than 660 gallons; The storage, handling, and processing of the following except medicines, beverages, foodstuff, cosmetics, and other common consumer items when packaged according to commonly accepted practices: More than 55 gallons of corrosive liquids; More than 500 pounds of oxidizing materials; More than 10 pounds of organic peroxides; More than 500 pounds of nitromethane; More than 1,000 pounds of ammonium nitrate; More than one microcurie of radium not contained in a sealed source or sources; More than one millicurie of radium or other radiation material in a sealed source or sources: Any amount of radioactive material for, which a specific license from the Nuclear Regulator Commission is required; More than ten pounds of flammable solids; Any installation of liquefied petroleum gas or liquefied natural gas utilizing storage containers of over 2,000 gallons individual water capacity or with an aggregate water capacity exceeding 4,000 gallons; The melting, casting, heat treating, machining, or grinding of more than ten pounds of magnesium per working day; Use of smoke generating device(s); Heliports. Type 5 Permit. The following activity requires a type 5 permit: Storage of hazardous materials in any quantity in any building more than six stories above grade, or more than 75 feet above the lowest level accessible to firefighting apparatus. B. Type 1A permit - $25.00; Type 1 - $125.00; Type 2 - $250.00; Type 3 - $375.00; Type 4 - $500.00; Type 5 - $1,500.00. C. Certificate of Smoke Detector and Carbon Monoxide Alarm Compliance (CSDCMAC) - (N.J.A.C. 5:70-2.3) - Fee: $75.00. D. Property search fee: $40.00. E. Fire incident report: Two pages or less, $5.00; for additional pages over two, $2.00. F. Fire investigation reports: Two pages or less, $5.00; for additional pages over two, $2.00. G. Fire code status inspection: $150.00. H. Apparatus stand-by, per hour per piece of apparatus: $500.00; includes fire apparatus utilized for fireworks, helicopter operations (minimum two apparatus), standpipe flow tests or any other operation deemed necessary by the Fire Official that requires Fire Division monitoring. It shall be the discretion of the Fire Official as to the number of apparatus required. I. Inspector stand-by: Supervisor, $70.00 per hour: Inspector, $55.00 per hour. J. Fire boat stand-by: $500.00 per hour. K. The use of flammable gas cylinders in food vending carts or vehicles in any amount shall require a type 1A permit for a $25.00 fee.
[Added 9-23-2014 by Ord. No. 14-117; amended 12-15-2021 by Ord. No. 21-078]
Ask a question about Jersey City law
Corpus searches the Jersey City sections it holds and shows the ones that match, with their citations. Free, no sign-in.