§ 94.36 — Alarm system specifications for newly constructed or altered commercial buildings

Code of Ordinances, City of Springfield, Illinois (Supp. No. 82: codified through Ordinance No. 146-04-26, enacted April 7, 2026) · Springfield, Ill., City Code § 94.36

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/61ef15d7-78ac-45df-9973-6e798d4ce390

§ 94.36 - Alarm system specifications for newly constructed or altered commercial buildings.

(a) Except as provided in subsection (b) below, the owner or his agent of any newly constructed commercial building that exceeds 10,000 square feet gross building area or exceeds two stories in height, or any existing commercial building that meets those requirements and is being altered or remodeled under a building permit or permits showing the cost of such to exceed $10,000.00, shall install a fire alarm detection system consisting of: (1) Fixed temperature detectors in any attic, mechanical, equipment, furnace room, and other areas where the circumstances dictate, as determined by the fire code official. (2) A rate of rise fixed temperature detectors in each room, basement and service area; or a fixed temperature detector that meets the requirements of NFPA Standard 72, 2019 edition, and other areas where the circumstances dictate, as determined by the fire code official. (3) Photoelectric smoke detectors in each corridor according to the manufacturers listed coverage. (4) A photoelectric smoke detector on the ceiling at the top of any stairway that is enclosed at the top landing. (5) Audible and/or visual fire alarm devices as required to notify all building occupants. (6) An outside weatherproof audible and visual fire alarm device. (7) Pull stations at points of egress and other areas where the circumstances dictate, as determined by the fire safety division. (8) An annunciator panel designed to indicate location of alarm by floor and/or other area identified by the fire safety division during the plan review. (9) A fire alarm control panel with approved emergency power. Rooms containing fire alarm control and communications equipment shall be identified in an approved manner in accordance with NFPA Standard 72, [2019] edition. (b) The owner or his agent of any newly constructed, or altered commercial building or assembly occupancy that is fully sprinklered shall install a fire alarm detection system consisting of: (1) Photoelectric smoke detectors in each corridor according to the manufacturers listed coverage. (2) A photoelectric smoke detector on the ceiling at the top of any stairway that is enclosed at the top landing. (3) Audible and/or visual fire alarm devices as required to notify all building occupants. (4) An outside weatherproof audible and visual fire alarm device. (5) Pull stations at points of egress and other areas where the circumstances dictate, as determined by the fire safety division. (6) A sprinkler flow alarm connected to a fire alarm control panel. (7) Tamper switches on all control valves of the sprinkler system connected to the fire alarm control panel. (8) An annunciator panel designed to indicate location of alarm by floor or other area identified by the fire safety division during the plan review. (9) A fire alarm control panel with approved emergency power. Rooms containing fire alarm control and communications equipment shall be identified in an approved manner in accordance with NFPA Standard 72, 2019 edition. (c) The fire alarm detection system set forth in subsections (a) and (b) shall be connected to an approved central station or remote station for 24-hour monitoring.

(Ord. No. 190-04-06, § 1(Exh. A), 4-4-06; Ord. No. 489-07-07, § 1(Exh. A), 7-17-07; Ord. No. 056-02-23, § 1(Exh. A), 2-21-23)