Corpus Christi Code of Ordinances § 14-291 Residential construction code.
Sec. 14-291. - Residential construction code.
The International Residential Code for One- and Two-Family Dwellings, 2021 Edition, as published by the International Code Council, is incorporated by reference and adopted as the Residential Construction Code for the City of Corpus Christi with the following local amendments (Additions to the International Residential Code are shown as underlined text. Deletions to the International Residential Code are shown as strikethroughs):
R101.1 Title. These provisions shall be known as the Residential Code for One- and Two-Family Dwellings of the City of Corpus Christi and shall be cited as such and will be referred to herein as "this code."
R102.5 Appendices. Provisions in the appendices shall not apply unless specifically referenced in the adopting ordinance. Appendices: AE Manufactured Housing used as Dwellings, AH Patio Covers, and AJ Existing Buildings and Structures are hereby adopted.
103.1 Creation of agency. The City of Corpus Christi Development Services is hereby created named and the official in charge thereof shall be known as the code official. The function of the agency shall be the implementation, administration, and enforcement of the provisions of this code.
R105.10 Homeowner's permit. A permit may be issued to property owners for construction, alteration, installation or repairs within the scope of this code, in a single-family residential building or mobile home owned and occupied by the property owner as their homestead. A permit shall not be issued to a property owner for construction, alteration, installation, or repairs to natural gas service systems unless the property owner is a State of Texas licensed master plumber.
R105.11 Demolition Permits. Demolition permits associated with a code official, building official, fire official, or board ordered demolition are valid for 30 days.
108.2 Schedule of permit fees. On buildings, structures, electrical, gas, mechanical and plumbing systems or alterations requiring a permit, a fee for each permit shall be paid as required, in accordance with the schedule as established by the applicable governing authority. Reference the City of Corpus Christi fee schedule.
P109.1.2 Plumbing, Mechanical, gas, liquefied petroleum gas (LPG) and electrical systems inspection. Rough inspection of plumbing, mechanical, gas, LPG and electrical systems shall be made prior to covering or concealment, before fixtures or appliances are set or installed, prior to framing inspection.
P109.1.2.1 LPG Installations. LPG installations shall be under the 2021 International Fire Code with City revisions and inspected by a state of Texas certified plumbing inspector.
Section R112 of the International Residential Code is deleted in its entirety. Refer to Section 14-206 Technical Construction Boards for details on the establishment, duties and powers, and appeals process of the construction trade advisory & appeals board.
Section R113 of the International Residential Code is deleted in its entirety. Refer to Section 14-207 Violations and Penalties.
TABLE R301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
[image omitted; see the official code]
R313.1 Townhouse automatic fire sprinkler systems. An automatic residential fire sprinkler system shall be installed in townhouses only when three (3) or more attached dwelling units are constructed, and transient uses (occupancies less than thirty (30) days) are allowed.
Exception: An automatic residential fire sprinkler system shall not be required where additions or alterations are made to existing townhouses that do not have an automatic residential fire sprinkler system installed.
R313.1.1 Design and installation. Automatic residential fire sprinkler systems for townhouses shall be designed and installed in accordance with Sections P2904 or NFPA 13D.
R313.2 One- and two-family dwellings automatic fire sprinkler systems. An automatic residential fire sprinkler system shall be installed in one- and two-family dwellings.
Exception: An automatic residential fire sprinkler system shall not be required for additions or alterations to existing buildings that are not already provided with an automatic residential sprinkler system.
Section R322 Flood-Resistant Construction is deleted in its entirety. See Code of Ordinances, Chapter 14 - Development Services: Part III; Article V - Flood Hazard Prevention Code.
Chapter 11 Energy Efficiency is deleted in its entirety. Please refer to City of Corpus Christi adopted Energy Code.
M1401.4 Outdoor installations. Equipment and appliances installed outdoors shall be listed and labeled for outdoor installation. Supports and foundations shall prevent excessive vibration, settlement, or movement of the equipment. Supports and foundations shall be in accordance with Section M1305.1.3.1.Equipment installed outdoors must be anchored to supports or foundations to resist the wind loads specified in section R301.2.1.1.
G2415.5 (404.5) Fittings in concealed locations. Fittings installed in concealed locations shall be limited to the following types:
1. Threaded elbows, tees, couplings, plugs and caps.
2. Brazed fittings.
3. Welded fittings.
4. Fittings listed to ANSI LC1/CSA 6.26 or ANSILC4/CSA 6.32.
5. All threaded bushings shall be prohibited.
G2415.12 (404.12) Minimum burial depth. Underground piping systems shall be installed at a minimum depth of 12 18 inches (457 mm) below grade. Except as provided for in G2415.12.1 If a minimum of eighteen (18) inches (257 mm) of cover cannot be maintained, the pipe must be installed in conduit or bridged (shielded).
P2503.5 Required inspections and testing. The code official, upon notification from the permit holder or the permit holder's agent, shall make the following inspections and such other inspections as necessary, and shall either release that portion of the construction or shall notify the permit holder or an agent of any violations that must be corrected. The holder of the permit shall be responsible for the scheduling of such inspections.
a. Rough-in inspection shall be made after trenches or ditches are excavated and bedded, piping installed, and before any backfill is put in place.
b. Top Out inspection shall be made after the roof, framing, fire blocking, fire stopping, draft stopping, and bracing is in place and all sanitary, storm, and water distribution piping is roughed-in, and prior to the installation of wall or ceiling membranes. A pressure test is required on all piping before the inspection is approved.
c. Final inspection shall be made after the building is complete, all plumbing fixtures are in place and properly connected, and the structure is ready for occupancy.
P2503.5.1(a) Water test for the Top Out installation shall be a minimum of the highest vent fitting in the system or minimum 5ft above finished floor.
P2503.8.1 Testing and certification of backflow devices. Backflow preventer assemblies shall be tested in accordance with Subsection 312.10.1 of the Plumbing Code as modified by Section 14-281 of the Corpus Christi Code.
SECTION P2504
TOILET FACILITIES FOR WORKERS
P2504.1 General. Toilet facilities shall be provided for construction workers and maintained in a sanitary condition. Construction worker toilet facilities of the non-sewer type shall conform to ANSI Z4.3.
P2504.2 Location. Toilet facilities shall be provided for construction workers at each construction site.
a. The construction projects must be within 500 feet of each other to share a toilet facility.
b. Each building permit applicant must have a toilet facility for his/her own project.
P2603.5.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be a minimum of 18 inches below finished grade at the point of septic tank connection. Building sewers shall be a minimum of 12 inches below grade. The minimum depth of building sewers and building sewers connected to private sewage disposal systems shall be determined by the code official.
P2902.6 Location of backflow preventers. Access shall be provided to backflow preventers as specified by the manufacturer's installation instructions. If needed, additional access and clearance must be provided for the required testing, maintenance, and repair. Access and clearance must require a minimum of one (1) foot (305 mm) between the lowest portion of the assembly and grade, floor, or platform. Installations elevated more than five (5) feet (1.53 m) above the floor or grade must be provided with a permanent platform capable of supporting five hundred (500) pounds and provide mechanical support.
P2903.9.1 Service valve. Each dwelling unit shall be provided with an accessible main shutoff valve near the entrance of the water service. The valve shall be a full open-type having nominal restriction to flow with provision for drainage, such as a bleed orifice or separate drain valve. Additionally, the water service shall be valved at the curb or property line in accordance with local requirements.
Exception: Required for water service lines greater than or equal to one and one-half (1½) inches.
P3005.2.2 Spacing. Cleanouts shall be installed not more than eighty (80) feet (24,384 mm) apart in horizontal drainage lines, measured from the upstream entrance of the cleanout.
P3005.2.3 Building drain and building sewer junction. There shall be a two-way double riser cleanout near the junction of the building drain and building sewer. The cleanout shall be either inside or outside the building wall, provided that it is brought up to finish grade or the lowest floor level.
P3005.2.5 Cleanout size. Cleanouts shall be the same nominal size as the pipe they serve up to four (4) inches (102 mm). For pipes larger than four (4) inches (102 mm) nominal size, the minimum size of the cleanout shall be four (4) inches (102 mm).
Exceptions:
1. A removable P-trap with slip- or ground-joint connections can serve as a cleanout for drain piping that is one size larger than the P-trap size.
2. Cleanouts located on stacks can be one size smaller than the stack size.
3. The size of cleanouts for cast-iron piping can be in accordance with the referenced standards for cast iron fittings as indicated in Table P3002.3.
4. A two-inch cleanout may be used in an island vent configuration with a three-inch horizontal branch drain where a vertical vent is not installed pursuant to section P3112.4.
P3005.3.1 Minimum velocity. Where conditions do not permit building drains and sewers to be laid with a fall as great as specified in section P3005.3, a lesser slope may be permitted, provided, however, that the computed velocity will not be less than two (2) feet per second.
Exception: When the drainage system cannot be designed to meet the prescribed code, the system must be designed by a licensed engineer.
P3112.4 A vertical vent must be installed on the drain line downstream of the island vent configuration unless the building drain branch line is at least three (3) inches (76 mm).
Part VIII of the International Residential Code is deleted. Refer to the National Electrical Code for One- and Two-Family Dwellings.
Chapter 42 Swimming Pools of the 2021 International Residential Code will refer to the 2021 International Swimming Pools and Spa Code.
(Ord. No. 030847, 5-17-2016; Ord. No. 031067, § 3, 2-14-2017; Ord. No. 031344, § 2, 1-23-2018; Ord. No. 031456, § 2, 6-19-2018; Ord. No. 031899, § 1, 10-15-2019; Ord. No. 032058, § 14, 3-17-2020; Ord. No. 032968, § 8, 1-31-2023; Ord. No. 033156, § 3, 9-5-2023)