§ 210.045 — Planned unit development standards
Salem Revised Code, City of Salem, Oregon (Supp. No. 26: codified through Ordinance No. 10-26, adopted August 10, 2026) · Salem Revised Code § 210.045
Corpus is an independent public-information project, not the official City of Salem website. Stable reference: corpuslaw.us/code/660a6150-dd2d-4ccf-b97d-528b53abe6bb
Sec. 210.045. - Planned unit development standards.
Planned unit developments must comply with the development standards set forth in this section. (a) General development standards. Planned unit developments shall conform to the general development standards set forth in Table 210-2. TABLE 210-2. GENERAL DEVELOPMENT STANDARDS Requirement | Standard | Limitations & Qualifications Minimum Number of Dwelling Units within PUD RA, RS, RM-I, RM-II and RM-III zones | Minimum number of dwelling units required in zone where PUD is located Maximum Number of Dwelling Units within PUD RA and RS zones | Max. 20 d.u./acre RM-I, RM-II, and RM-III zones | Maximum number of dwelling units allowed in zone where PUD is located Maximum Number of Dwellings Units within a Building RA, RS, RM-I, RM-II, and RM-III zones | No maximum | The number of dwelling units within an individual building shall not exceed the overall maximum number of dwelling units allowed for the entire PUD. (b) Setbacks. Unless otherwise provide in this chapter, setbacks within a PUD shall be provided as set forth in Table 210-3. TABLE 210-3. SETBACKS Requirement | Standard | Limitations & Qualifications PUD Perimeter Setbacks—Abutting Street Buildings All uses | Min. 12 ft. | Applicable along local streets. Min. 20 ft. | Applicable on collector or arterial streets. None | Applicable along private streets. When a driveway approach is present, buildings shall be setback to maintain adequate vision clearance as required under SRC chapter 805. Accessory Structures Accessory to all uses | Min. 12 ft. | Applicable along local streets. Min. 20 ft. | Applicable on collector or arterial streets. None | Applicable along private streets. When a driveway approach is present, accessory structures shall be setback to maintain adequate vision clearance as required under SRC chapter 805. PUD Perimeter Setbacks—Not Abutting Street Interior Side Buildings All uses | Min. 5 ft., plus 1 ft. for each 1 ft. of height over 35 ft., but need not exceed 20 ft. in depth. Accessory Structures Accessory to all uses | None | Applicable to accessory structures having at least 1 wall which is an integral part of a fence. Min. 5 ft. | Applicable to all other accessory structures. Interior Rear Buildings All uses | Min. 14 ft. | Applicable to any portion of a building not more than 1 story in height, when the interior rear yard abuts the interior rear yard of an RA or RS zoned lot located outside the PUD. Min. 20 ft. | Applicable to any portion of a building greater than 1 story in height, when the interior rear yard abuts the interior rear yard of an RA or RS zoned lot located outside the PUD. Min. 5 ft., plus 1 ft. for each 1 ft. of height over 35 ft., but need not exceed 20 ft. in depth. | Applicable when the interior rear yard does not abut the interior rear yard of an RA or RS zoned lot located outside the PUD. Accessory Structures All uses | None | Applicable to accessory structures not more than 9 ft. in height. Min. 1 ft. for each 1 ft. of height over 9 ft. | Applicable to accessory structures greater than 9 ft. in height. Min. 1 ft. | Applicable to accessory structures adjacent to an alley, unless a greater setback is required based on the height of the accessory structure. PUD Interior Setbacks—Abutting Street Buildings All uses | Min. 12 ft. | Applicable along local streets. Min. 20 ft. | Applicable along collector or arterial streets. None | Applicable along private streets. When a driveway approach is present, buildings shall be setback to maintain adequate vision clearance as required under SRC chapter 805. Accessory Structures Accessory to all uses | Min. 12 ft. | Applicable along local streets. Min. 20 ft. | Applicable along collector or arterial streets. None | Applicable along private streets. When a driveway approach is present, buildings shall be setback to maintain adequate vision clearance as required under SRC chapter 805. PUD Interior Setbacks—Not Abutting Street Interior Front Buildings All uses | None Accessory Structures Accessory to all uses | None Interior Side Buildings All uses | None Accessory Structures Accessory to all uses | None Interior Rear Buildings All uses | None Accessory Structures Accessory to all uses | None Abutting Waterway(1) Buildings Single family | Min. 100 ft. | Applicable to townhouses constructed after March 16, 2022 None | Applicable to all other single family. All other setbacks required abutting streets and interior front, side, and rear property lines still apply. Two family, three family, four family, and multiple family | Min. 100 ft. All other uses | None | All other setbacks required abutting streets and interior front, side, and rear property lines still apply. Accessory Structures None | All other setbacks required abutting streets and interior front, side, and rear property lines still apply. (1) Waterway setback does not apply to Planned Unit Developments approved prior to March 16, 2022. (c) Height. Buildings and accessory structures within a PUD shall conform to the height standards set forth in Table 210-4. TABLE 210-4. HEIGHT Requirement | Standard | Limitations & Qualifications Height Buildings All uses | Max. 35 ft. | Applicable within the RA, RS, RM-I, and RM-II zones No Maximum | Applicable within the RM-III zone Accessory Structures Accessory to all uses | Max. 15 ft. (d) Parking.Except as provided in this subsection, parking within a PUD shall be developed in conformance with the standards set forth in SRC chapter 806. (1) Off-street parking development standards. Parking within a PUD shall conform to the following standards: (A) Location. Parking spaces provided within the planned unit development, may be located either on-street, off-street, or a combination thereof. (B) Garage or carport vehicle entrance setback abutting street or flag lot accessway. The vehicle entrance of a garage or carport facing a street or flag lot accessway shall be set back a minimum of 20 feet from one of the following lines, whichever is closest to the proposed vehicle entrance of the garage or carport: (i) The street right-of-way line, most interior access easement line, or property line abutting a flag lot accessway; (ii) The outside curbline; or (iii) The edge of the sidewalk furthest from the street. (C) Dimensions. On-street parallel parking spaces shall be at least seven feet in width and 22 feet in length. (D) Landscaping and screening. All off-street parking areas, other than those within a garage or carport, or on a driveway leading to a garage or carport, shall be effectively landscaped, designed to minimize the effect of a large number of cars in one area, and screened with ornamental evergreens or architectural features such as fences and walls. (e) Side lot lines. As far as is practicable, side lot lines shall run at right angles to the street upon which the lot faces, except that on curved streets they shall be radial to the curve. (f) Limits on common open space. Streets, parking areas, traffic circles, and other similar transportation related improvements shall not be considered, or considered to be a part of, common open space. (g) Utilities. Except for stormwater management facilities, all utility services shall be undergrounded.
(Prior Code, § 210.045; Ord. No. 31-13; Ord. No. 13-21, § 1(Exh. A), 2-14-2022; Ord. No. 11-22, § 1(Exh. A), 7-25-2022, eff. 8-24-2022; Ord. No. 4-23, § 1(Exh. A), 4-24-2023)
Ask a question about Salem law
Corpus searches the Salem sections it holds and shows the ones that match, with their citations. Free, no sign-in.
