§ 32D.05 — Regulation of Towers in Excess of One Hundred Twenty-Five Feet in Height

Cedar Rapids, Iowa, Municipal Code (Supp. No. 25, Update 1: codified through Ordinance No. 025-26, passed July 28, 2026) · Cedar Rapids Municipal Code § 32D.05

Corpus is an independent public-information project, not the official City of Cedar Rapids website. Stable reference: corpuslaw.us/code/66b3b3b2-8331-4223-83fd-d20b509da899

32D.05 - Regulation of Towers in Excess of One Hundred Twenty-Five Feet in Height.

Application. A building permit and/or conditional use permit shall be obtained prior to construction of communications towers in excess of 125 feet in height. Towers shall be registered at the time the permit is obtained. Each application for a permit shall include the following information, supplied by the tower owner, operator or contractor installing the tower: Site plan drawn to scale specifying the location of tower(s), guy anchors (if any), transmission building and other accessory uses, parking, access, landscape areas (specifying size, spacing and plant materials proposed), fences and adjoining property uses; Plans and specifications from a registered professional engineer, licensed in the State of Iowa and experienced in the design and/or analysis of communications towers. The plans and specifications shall include: Tower height; Type of structure; Type of materials; Specification for materials used for structural elements of tower; Name of tower manufacturer; Soils investigation (where required for footing design); Method of installation or erection; List of the type and location of all antennas, cables and other appurtenances which will be installed at the time the tower is erected; List of the type and location of all antennas, cables and other appurtenances which may be installed in the future. This plan and specification shall include a statement that to the best of the engineer's knowledge, information and belief, the proposed structure has been designed in accordance with all of the following: The current Uniform Building Code (as adopted by the City of Cedar Rapids); Applicable ordinances as adopted by the City of Cedar Rapids; The current version of EIA 222, Structural Standards for Steel Antenna Towers and Antenna Support Structures. The structure shall be designed for the maximum stresses or forces resulting from the following combinations: Dead load of structure, plus the weight of all antennas, cables or appurtenances (including those to be placed on the structure at the time of construction and those anticipated for future placement), plus a load generated by applying a basic wind speed of 90 miles per hour to all tower members, cables, antennas and other appurtenances on the tower. Dead load of structure, plus the weight of all antennas, cables or appurtenances (including those to be placed on the structure at the time of construction and those anticipated for future placement), plus 75% of a load generated by applying a basic wind speed of 90 miles per hour to all tower members, cables, antennas and other appurtenances on the tower, plus 100% of the weight of 1/2 inch of ice applied radially to all tower members, cables, antennas and other appurtenances on the tower. The tower owner shall supply a letter from the contractor stating that the tower has been installed according to the design submitted to obtain the building permit. This letter shall be accompanied by as-built drawings and test results. Other supporting information shall be submitted as required by the Building Official or an authorized representative. Setbacks. Setbacks for tower installation shall comply with Section 32.02 of the City of Cedar Rapids Zoning Regulations. Landscaping. Tower sites shall be landscaped as required by the zoning ordinance. Security. Access by the general public to the tower and all guy anchors (if any) shall be restricted by the use of security fencing or other obstacles not less than 8 feet in height. Appropriate signage shall be posted indicating that trespassing and/or vandalism to the property may be punishable under local, state or federal statutes. Inspections. Tower owners shall maintain, at their own expense, a tower modification and maintenance log which shall be made available for inspection by the city Building Department upon demand during regular business hours. At least once every 36 months the tower shall be inspected by an independent expert who is regularly involved in the maintenance, inspection and/or erection of communications towers. This inspection shall be conducted in accordance with the tower inspection checklist provided in the EIA standard as applicable. The Building Department shall be notified in writing when the inspection is complete and a copy of the inspection report shall be made available to the department upon request. At least once every 12 months a visual inspection shall be performed by properly trained staff or tower consultant. This inspection shall include tower foundations, structures, guys, and connections from the ground for evidence of settlement or lateral movement, soil erosion, condition of paint or galvanizing, rust or corrosion, loose or missing bolts, loose or corroded lightning protection connectors, tower plumbness, significant variation in guy sags (i.e., guy tensions), etc. A structural inspection shall be performed if high winds, ice storms or other events have caused visible damage to the tower or its appurtenances. The Building Department shall be notified in writing when the inspection is complete, and a copy of the inspection report shall be made available to that department upon request. Compliance with Standards. Current or former EIA standards shall apply to the addition of antennas or other appurtenances to communications towers under the following conditions: Additions to towers constructed prior to the adoption of the ordinance codified in this chapter, regardless of whether the additions were accounted for in the original design, shall comply with the current EIA standard, and the wind loading specified therein, and shall include the ½ inch of radial ice requirement described in Section 32D.05(a)3.c.2 of this chapter. Additions to towers constructed subsequent to the passage of this ordinance shall comply with standards set forth in Section 32.05(h) of this chapter. If the EIA standard has changed since the tower was designed, a structural analysis shall be performed before any appurtenances or equipment are added. Existing towers which will not have any appurtenances added to them may comply with the EIA standard in existence at the time the tower was erected. Replacement of antennas or other appurtenances may comply with the EIA standard in existence at the time the tower was erected if the replacement does not add to the original design loading. If a structural analysis shows a tower is not in compliance with the appropriate EIA standard, the owner shall notify the city Building Department promptly, and provide that department with a plan to bring the tower into compliance within 6 months. The city Building Department shall be notified in writing when a required analysis is complete. A copy of the analysis report shall be made available to that department upon request. That report shall also give details of the net result of any changes made to the tower or its appurtenances since the last inspection. Registration. Owners and/or operators of all towers in excess of 125 feet in height shall register their towers with the city Building Department within 60 days of the passage of the ordinance codified in this chapter. Registration shall include the following information: Name and address of the tower owner; Name and address of the tower operator; Name, address, title and phone number of primary contact person; Address of the tower; Principal use of the tower; Tower height; A list of appurtenances on the tower, including model numbers, if available, and their location on the tower, or a drawing indicating location; Date of the last structural analysis; Site plan; Date of the last inspection. Analysis of Existing Towers. Within 12 months prior to or following the passage of the ordinance codified in this chapter, an analysis shall be performed on all towers in excess of 125 feet in height. This analysis shall determine the tower's compliance or lack thereof with the EIA standard in effect at the time the tower was constructed or when the most recent structural loading change was made. The tower owner shall, within 30 days of completion of the analysis or the passage of the ordinance codified in this chapter, provide the Building Department with a letter from a registered professional engineer licensed in the state of Iowa stating the current structural status of the tower. If the tower does not meet the aforementioned EIA standard, the letter shall indicate what would be required to bring the tower up to standard. (057-18)

Ask a question about Cedar Rapids law

Corpus searches the Cedar Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.