For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 36-434.15 — Multifamily and nonresidential developments

The Little Rock City Code, Revised 1988 (Supp. No. 83: codified through Ordinance No. 22,703, enacted December 16, 2025) · Little Rock City Code § 36-434.15

Corpus is an independent public-information project, not the official City of Little Rock website. Stable reference: corpuslaw.us/code/66d5b8d4-a3e4-4c2e-ba4a-624df24ec60f

Sec. 36-434.15. - Multifamily and nonresidential developments.

The multifamily and nonresidential developments regulations shall apply to all zoning districts except R-2, R-3 and R-4 within the district, and shall apply to all churches and schools, regardless of underlying zoning within the district. A. Building form. New and renovated buildings (more than fifty (50) percent exterior surface area altered) shall be compatible with existing scale, setbacks, and mass of the buildings in the immediate area (e.g., along Kavanaugh Boulevard most buildings have minimum setbacks from the street, whereas along Beechwood the former residences have setbacks with yards). 1. Facades. Street-level facades shall reflect the same building materials as existing commercial buildings in the one-block area adjacent to and across from the location. Predominant exterior building materials may be any standard material, except corrugated or ribbed materials, smooth-faced concrete block, tilt-up concrete panels, or prefabricated steel panels. 2. Setbacks. Setbacks from street and alley shall meet current code requirements, except setbacks may align with surrounding structures. Front-yard setbacks on Kavanaugh Boulevard between Rose Street and L Street shall not exceed ten (10) feet. A minimum of fifty (50) percent of the front facade must be constructed along this line. Front yard and side yard setback on existing and proposed buildings shall be measured from twelve (12) inches above grade on the closest vertical surface measured to the appropriate property line. 3. Height. Maximum building height shall be thirty-nine (39) feet, measured from the "grade plane" to the ridge line of the highest roof surface or parapet wall. 4. Building form. (a) Wall projections or recesses a minimum of three (3) feet depth and a minimum of twenty (20) contiguous feet not to extend over twenty (20) percent of the facade shall be required. Arcades, display windows, entry areas or awnings shall exist along at least sixty (60) percent of the facade. (b) Buildings shall maintain a distinction between upper and lower levels; any elevation greater than eighteen feet in height shall contain an architectural treatment, which visually divides the structure into "stories". (c) Roof lines shall be varied with a change in height every one hundred (100) linear feet in building length. Parapets, mansard roofs, gable roofs, high roofs shall be used to conceal flat roofs and roof top equipment. B. Parking. 1. Standard parking requirements. Parking requirements within the district shall be fifty (50) percent of that required by article VIII. The maximum parking allowed for this district shall be the minimum standard established in article VIII. Multifamily developments or mixed-use developments that contain residential units must provide the minimum number of parking spaces as required in section 36-502 for those residential units. All other parking for the mixed-use facility may develop at the requirements stated in this division. 2. Off-site parking. Where on-street parking is allowed it shall be credited toward the parking requirements at a rate of one (1) space per ten (10) linear feet of street frontage. Parking spaces within a common parking facility may be counted toward the parking requirements of any development. The total number of parking spaces within the common parking facility shall not be less than the sum of requirements for the various individual uses utilizing the facility. 3. Parking facilities. Surface parking shall be limited to the side and rear of structures. No parking shall be allowed in the "front yard" setback. Surface parking is to be located behind or adjacent to a structure, never between the building and any abutting street. Any parking structure shall be required to have active uses on the street level other than parking (such as quiet office, or neighborhood retail uses). C. Utilities and services. All new developments are required to place utilities and cabled services in subterranean locations from the pole to the structure. D. Signage. Permitted signs shall be as in section 36-553, Signs permitted in institutional and office zones. On the street level, the maximum area of signage may be doubled if at least fifty (50) percent of the street-level office and retail space has direct access to the street. The highest point on any commercial sign attached to the building shall not exceed the corresponding building's height. * Freestanding commercial signs may not exceed eighteen (18) feet in height. * Neon-lit signs greater than thirty (30) square feet are prohibited. * Off-premises signs are prohibited. E. Lighting. 1. The purpose of this section is to regulate the intensity of exterior lighting. The intent is to prevent light from commercial developments from excessively illuminating the property in question, other properties, or the night sky. 2. Only light fixtures that are categorized as full cut-off (FCO) fixtures shall be permitted. The use of fully shielded (FCO) floodlights are permitted but not encouraged. 3. The following are specific standards for lighting intensity based upon the activities performed involved. Values are presented in allowable footcandles (fc) maintained (measured horizontally) at grade and are to be averaged throughout the site to avoid hot spots, i.e.; areas of extreme light intensity relative to the remainder of the site: Land Use | Minimum | Maximum Pedestrian areas/sidewalks | 0.2 fc | 1.0 fc Building entries | 1.0 fc | 10.0 fc Street lighting | 0.2 fc | 1.0 fc Parking areas | 2.0 fc | 4.0 fc Playgrounds | 5.0 fc Sports grounds | 20.0 fc Site perimeter | 0.5 fc 4. Gas station canopies shall be illuminated at a maximum luminance of thirty (30) fc and individual fixtures shall be flush-mounted or have the canopy edge below the lowest light-emitting point on the fixtures. 5. Up lighting may be used to illuminate a building, landscaping element or architectural feature, provided the lighting design has a maximum luminance of twelve (12) fc, measured in a vertical plane. Down lighting is preferred. 6. A lighting plan shall be submitted for staff review and approval prior to issuance of building permits. The plan shall contain the following information: (a) An area lighting plan, drawn to scale, indicating all structures, parking lots, building entrances, vehicular and pedestrian traffic areas, vegetation that may interfere with lighting, and adjacent land uses that may be adversely impacted by the lighting. The plan shall contain a layout of all proposed fixtures by location, orientation, aiming direction, mounting height and type. (b) The submission shall include, in addition to proposed area lighting, all other exterior lighting, e.g., architectural, building entrance, landscape, flagpole, sign, etc. (c) A ten-foot luminance grid (point by point) of maintained foot-candles overlaid on the site plan plotted out to 0.0 footcandles, which demonstrates compliance with light intensity standards.

(Ord. No. 20,223, § 2, 3-2-10)

Ask a question about Little Rock law

Corpus searches the Little Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.