Sec. 7-384. - Light and ventilation.

(a) Windows. Every habitable room shall have at least one window or skylight facing directly to the outdoors. The minimum total window area, measured between stops, for every habitable room shall be eight percent of the floor area of such room. Whenever walls or other portions of structures face a window of any such room and such light-obstructing structures are located less than three feet from the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area. Whenever the only window in a room is a skylight-type window in the top of such room, the total window area of such skylight shall be equal to at least 15 percent of the total floor area of the room. (b) Ventilation. (1) Every habitable room shall have at least one window or skylight which can easily be opened, or such device as will adequately ventilate the room. The total openable window area in every habitable room shall equal at least 45 percent of the minimum window area size or minimum skylight-type window size, as required, or shall have other approved, equivalent ventilation. (2) Year-round mechanically ventilating conditioned air systems may be substituted for windows, as required in this section, in rooms other than rooms used for sleeping purposes. Window-type air conditioning units are not included in this exception. (c) Bathroom. Every bathroom shall comply with the light and ventilation requirements for habitable rooms, except that no window or skylight shall be required in adequately ventilated bathrooms equipped with an approved ventilating system. (d) Electric lights and outlets. Where there is electric service available to the building structure, every habitable room or space shall contain at least two separate and remote electrical receptacle outlets. Bedrooms shall have, in addition, at least one wall switch controlled lighting fixture or outlet. In kitchens, two separate and remote electrical receptacle outlets and a wall or ceiling type lighting fixture controlled by a wall switch shall be required. An electrical receptacle outlet rendered inaccessible by appliances shall not be considered as one of the required outlets in a kitchen area. Every hall, water closet compartment, bathroom, laundry room or furnace room shall contain at least one wall or ceiling type light fixture. In bathrooms and water closet compartments, the light fixture shall be controlled by a wall switch. In addition to the light fixture in every bathroom and laundry room, there shall be provided at least one electrical receptacle outlet. Any bathroom, kitchen or outside electrical receptacle outlet shall have ground-fault circuit interrupter (GFI) protection. (e) Light in public halls and stairways. Every common hall and inside stairway in every building, other than one-family dwellings, shall be adequately lighted at all times with an illumination of at least one footcandle intensity at the floor in the darkest portion of the normally traveled stairs or passageway.

(Ord. No. 90-174, § 303, 4-26-1990; Ord. No. 07-171, § 12, 3-8-2007)

Ask a question about Huntsville law

Corpus searches the Huntsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.