Sec. 49-1211. - Exceptions regarding roof drain systems.
Roof drain systems installed using exceptions shall be discharged to daylight no more than 18 inches above grade or connected to the building storm sewer after first passing through an area inlet or manhole with a grated cover within 15 feet of the building. The following provisions shall also be observed: (a) An overflow roof drain system is not required for a flat style roof if parapet walls are on no more than three sides and provided that the open side of the roof edge has an elevation of two inches or less above the low point of the roof. (For sizing requirements, see Tables 49-1204a and 49-1204b.) (b) An overflow roof drain system is not required if the building is higher than 70 feet (approximately five stories) and the size and quantity of roof drains is determined by Tables 49-1211a and 49-1211b. However, an overflow drain system will be required for any roof portions of the same building which do not reach 70 feet. Table 49-1211a * Maximum Projected Area of the Roof for Drains for Systems Without Overflows Drain Size (inches) | Area (ft 2 ) 3 | 548 4 | 1,253 Table 49-1211b * Maximum Projected Area of the Roof for Piping of Various Slopes for Systems Without Overflows Pipe Size (Inches) | ⅛" Slope (ft 2 ) | ¼" Slope (ft 2 ) | ½" Slope (ft 2 ) 3 | 548 | 773 | 1,147 4 | 1,253 | 1,766 | 2,505 5 | 2,226 | 3,146 | 4,450 6 | 3,566 | 5,033 | 6,850 8 | 7,665 | 10,866 | 15,325 10 | 13,800 | 19,475 | 27,600 12 | 22,200 | 31,300 | 44,400 15 | 36,400 | 56,000 | 79,400 * Based on a maximum rainfall rate of three inches per hour. (c) If the building height exceeds 70 feet (approximately five stories), the overflow drain piping may be connected into the primary roof drain piping at least ten feet below the primary drain connection to the vertical stack, provided that a flow sensor is installed in the overflow system which, when engaged, activates an audible alarm to notify the building occupants that the primary roof drain pipe is blocked and water is running through the overflow drain system.
(Ord. No. 40524, § 1, 10-20-15)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.